Smoke and heat control systems — Part 4: Natural smoke and heat exhaust ventilators — Design, requirements and installation

This document applies to the design and installation of natural smoke and heat exhaust ventilators (NSHEVs) for spaces from which smoke is extracted vertically by thermal buoyancy via the roof in the case of single-storey buildings and via the uppermost storey in the case of multi-storey buildings. It also applies to spaces in which NSHEVs are installed in external walls. This document includes tables and calculation methods for the design of clear layers in order to comply with the requirements of various protection objectives. This document includes information and provisions to be taken into account when applying the design rules set out herein and when installing NSHEVs.

Systèmes pour le contrôle des fumées et de la chaleur — Partie 4: Exutoires de fumées et de chaleur naturels — Dimensionnement, exigences et mise en place

General Information

Status
Published
Publication Date
01-Apr-2019
Current Stage
9020 - International Standard under periodical review
Start Date
15-Apr-2024
Completion Date
15-Apr-2024
Ref Project

Buy Standard

Standard
ISO 21927-4:2019 - Smoke and heat control systems
English language
16 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 21927-4
First edition
2019-04
Smoke and heat control systems —
Part 4:
Natural smoke and heat exhaust
ventilators — Design, requirements
and installation
Systèmes pour le contrôle des fumées et de la chaleur —
Partie 4: Exutoires de fumées et de chaleur naturels —
Dimensionnement, exigences et mise en place
Reference number
ISO 21927-4:2019(E)
©
ISO 2019

---------------------- Page: 1 ----------------------
ISO 21927-4:2019(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 21927-4:2019(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols and abbreviated terms . 2
5 Design principles . 2
5.1 General . 2
5.2 Height of space . 3
5.3 Target height of the clear layer, height of smoke barrier . 3
5.4 Area of smoke reservoir . 4
5.5 Air inlets . 4
5.6 Duration of fire growth . 5
5.7 Theoretical fire area, design groups . 5
5.8 Aerodynamic effectiveness of NSHEVs . 6
6 Design . 6
6.1 General . 6
6.2 Smoke exhaust openings in roofs . 6
6.3 Smoke exhaust ope
...