Space systems — Fluid characteristics, sampling and test methods — Part 3: Nitrogen

ISO 15859-3:2004 specifies limits for the composition of nitrogen and establishes the sampling and test requirements applicable for the verification of nitrogen composition. ISO 15859-3:2004 is applicable to nitrogen, used in both flight hardware and ground facilities, systems and equipment, of the following types and grades of nitrogen: Type I, gaseous (Grade A: purging/pressurizing, Grade B: crew breathing, Grade C, Grade F, Grade J) and Type II, liquid (Grade A: purging/pressurizing, Grade B: crew breathing, Grade C, Grade F). ISO 15859-3:2004 is applicable to influents only within the specified limits. ISO 15859-3:2004 is applicable to any sampling operation required to ensure that, when the fluid enters the launch vehicle or spacecraft, the fluid composition complies with the limits provided hereafter or with any technical specification agreed to for a particular use.

Systèmes spatiaux — Caractéristiques, échantillonnage et méthodes d'essai des fluides — Partie 3: Azote

L'ISO 15859-3:2004 donne les valeurs limites de la composition de l'azote et établit les exigences relatives à son échantillonnage et aux méthodes d'essai applicables pour vérifier sa composition. L'ISO 15859-3:2004 est applicable à l'azote des types et qualités suivants, utilisé à la fois dans le matériel embarqué et dans les installations, systèmes et équipements au sol: type I, gazeux (qualité A: purge/pressurisation, qualité B: respiration de l'équipage, qualité C, qualité F, casse J) et type II, liquide (qualité A: purge/pressurisation, qualité B: respiration de l'équipage, qualité C, qualité F). L'ISO 15859-3:2004 n'est applicable aux fluides entrant dans le système spatial que dans les limites spécifiées. L'ISO 15859-3:2004 est applicable à toute opération d'échantillonnage nécessaire pour garantir que, lorsque le fluide pénètre dans le lanceur ou dans le véhicule spatial, sa composition est conforme aux valeurs limites définies ci-après ou aux spécifications techniques approuvées en vue d'une utilisation particulière.

General Information

Status
Published
Publication Date
07-Jun-2004
Current Stage
9093 - International Standard confirmed
Completion Date
18-Jan-2020
Ref Project

Buy Standard

Standard
ISO 15859-3:2004 - Space systems -- Fluid characteristics, sampling and test methods
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 15859-3:2004 - Systemes spatiaux -- Caractéristiques, échantillonnage et méthodes d'essai des fluides
French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 15859-3
First edition
2004-06-01
Space systems — Fluid characteristics,
sampling and test methods —
Part 3:
Nitrogen
Systèmes spatiaux — Caractéristiques, échantillonnage et méthodes
d'essai des fluides —
Partie 3: Azote
Reference number
ISO 15859-3:2004(E)
ISO 2004
---------------------- Page: 1 ----------------------
ISO 15859-3:2004(E)
PDF disclaimer

This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but

shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In

downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat

accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.

Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation

parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In

the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

© ISO 2004

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,

electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or

ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2004 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 15859-3:2004(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies

(ISO member bodies). The work of preparing International Standards is normally carried out through ISO

technical committees. Each member body interested in a subject for which a technical committee has been

established has the right to be represented on that committee. International organizations, governmental and

non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the

International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.

International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.

The main task of technical committees is to prepare International Standards. Draft International Standards

adopted by the technical committees are circulated to the member bodies for voting. Publication as an

International Standard requires approval by at least 75 % of the member bodies casting a vote.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent

rights. ISO shall not be held responsible for identifying any or all such patent rights.

ISO 15859-3 was prepared by Technical Committee ISO/TC 20, Aircraft and space vehicles, Subcommittee

SC 14, Space systems and operations.

ISO 15859 consists of the following parts, under the general title Space systems — Fluid characteristics,

sampling and test methods:
 Part 1: Oxygen
 Part 2: Hydrogen
 Part 3: Nitrogen
 Part 4: Helium
 Part 5: Nitrogen tetroxide propellants
 Part 6: Monomethylhydrazine propellant
 Part 7: Hydrazine propellant
 Part 8: Kerosine propellant
 Part 9: Argon
 Part 10: Water
 Part 11: Ammonia
 Part 12: Carbon dioxide
 Part 13: Breathing air
© ISO 2004 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 15859-3:2004(E)
Introduction

Fluid operations at a spaceport or launch site may involve a number of operators and supplier/customer

interfaces, from the fluid production plant to the delivery to the launch vehicle or spacecraft. The purpose of

ISO 15859 is to establish uniform requirements for the components, sampling and test methods of fluids used

in the servicing of launch vehicles, spacecraft and ground support equipment. The fluid composition limits

specified are intended to define the purity and impurity limits of the fluid for loading into the launch vehicle or

spacecraft. The fluid sampling and test methods are intended to be applied by any operator. The fluid

sampling and test methods are acceptable methods for verification of the fluid composition limits.

iv © ISO 2004 – All rights reserved
---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 15859-3:2004(E)
Space systems — Fluid characteristics, sampling and test
methods —
Part 3:
Nitrogen
1 Scope

This part of ISO 15859 specifies limits for the composition of nitrogen and establishes the sampling and test

requirements applicable for the verification of nitrogen composition.

This part of ISO 15859 is applicable to nitrogen, used in both flight hardware and ground facilities, systems

and equipment, of the following types and grades of nitrogen.
 Type I: gaseous
 Grade A: purging/pressurizing,
 Grade B: crew breathing,
 Grade C,
 Grade F,
 Grade J;
 Type II: liquid
 Grade A: purging/pressurizing,
 Grade B: crew breathing,
 Grade C,
 Grade F.

This part of ISO 15859 is applicable to influents only within the specified limits herein.

This part of ISO 15859 is applicable to any sampling operation required to ensure that, when the fluid enters

the launch vehicle or spacecraft, the fluid composition complies with the limits provided hereafter or with any

technical specification agreed to for a particular use.
2 Normative references

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.
ISO 9000, Quality management systems — Fundamentals and vocabulary
© ISO 2004 – All rights reserved 1
---------------------- Page: 5 ----------------------
ISO 15859-3:2004(E)
3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 9000 and the following apply.

3.1
direct method

method of measuring fluid purity by direct means as opposed to the indirect method

NOTE A measurement device or analyser can be used as a direct means for measuring the fluid purity.

3.2
indirect method

method of measuring fluid purity by indirect means, which consists in measuring the total volume fraction or

mass fraction (in %) of aggregate impurities and subtracting this total from 100 %

3.3
total hydrocarbon content (as methane)
single carbon atom equivalent
3.4
verification test

analysis performed on the fluid in the container, or a sample thereof, which is representative of the supply,

permitting the verification of fluid composition limits
4 Chemical composition

Unless otherwise provided in an applicable technical specification, the composition of nitrogen delivered to the

flight vehicle interface shall be in accordance with the limits given in Table 1 when tested in accordance with

the applicable test methods.
2 © ISO 2004 – All rights reserved
---------------------- Page: 6 ----------------------
ISO 15859-3:2004(E)
Table 1 — Composition limits
Limits
Component Type I and Type II (gaseous and liquid) Type I
Grade A Grade B Grade C Grade F Grade J
Volume fraction,
Nitrogen 99,5 99,995 99,9 99,999
%, min.
Water µl/l, max.26,3 11,5 5,7 15 10
Total hydrocarbons as
µl/l, max. 58,3 5,0 25
5,0 
methane (CH )
Oxygen µl/l, max. 5 000 50 20 1 000 5
e e e
Hydrogen µl/l, max. 0,5 
e e
Argon µl/l, max. 20 2,0 
e e
Carbon dioxide µl/l, max. 5,0 5,0 
e e
µl/l, max. 5,0 5,0 
Carbon monoxide
Aromatic hydrocarbons as
µl/l, max. 0,5
   
benzene
Halogenated hydrocarbons µl/l, max.  1,0   
µl/l, max.  0,1   
Chlorinated hydrocarbons
µl/l, max. 1,0
Nitrous oxide    
Odour None
   
mg/l, max. 1,0 1,0
Particulate matter   
Total impurities µl/l, max. 5 000 100 50 1 000 10

Nitrogen (in percent) includes trace quantities of neon, helium, and small amounts of argon.

If required by use.
Applies only to Type II (liquid) nitrogen.

Sum of all percentages of water, hydrocarbons, oxygen, hydrogen, and if applicable, carbon monoxide, carbon dioxide,

and argon.
No limit for this grade.
By indirect method 99,99 % or by direct method 95,0 %.
For environmental-control-and-life-support-system (ECLSS) ground test only.
5 Procurement

Nitrogen types and grades specified in Clause 1 should be procured in accordance with an applicable national

standard.
© ISO 2004 – All rights reserved 3
---------------------- Page: 7 ----------------------
ISO 15859-3:2004(E)
6 Fluid sampling

CAUTION — Gaseous nitrogen is an asphyxiant. Human contact with liquid nitrogen will result in

severe injury. Care should be taken in the handling and storage of liquid nitrogen to prevent contact

with the human body. Care should also be taken to prevent high concentrations of gaseous nitrogen

in confined spaces.
6.1 Plan

In order to ensure that the fluid composition complies with the limits specified in this part of ISO 15859, a fluid

sampling plan should be established by all the involved operators, from the production to the space vehicle

interface, and approved by the final user. Sampling activities and test methods shall comply with all safety

regulations and rules applicable to that task. This plan shall specify
 the sampling points,
 the sampling procedures,
 the sampling frequency,
 the sample size,
 the number of samples,
 the test methods, and
 the responsibilities of any involved operator.
6.2 Responsibility for sampling

Unless otherwise provided in an applicable technical specification, the nitrogen delivered to the flight vehicle

interface shall be sampled and verified by the supplier responsible for providing the nitrogen to the flight

vehicle. The supplier may use his/her or any other resources suitable for the performance of the verification

tests specified herein unless otherwise directed by the customer.
6.3 Sampling points

Unless otherwise specified, sampling shall be conducted at the fluid storage site or the flight vehicle interface.

6.4 Sampling frequency

Sampling shall be performed annually or in accordance with a time agreed upon by the supplier and the

customer.
6.5 Sample size

The quantity in a single sample container shall be sufficient to perform the analysis for the limiting

characteristics. If a single sample does not contain a sufficient quantity to perform all of the analyses for the

required quality verification test, additional samples shall be taken under similar conditions.

6.6 Number of samples
The number of samples shall be in accordance with one of the following:
a) one sample per storage container;
b) any number of samples agreed upon by the supplier and the customer.
4 © ISO 2004 – All rights reserved
---------------------- Page: 8 ----------------------
ISO 15859-3:2004(E)
6.7 Storage container

Unless otherwise provided by the applicable sampling plan, the fluid storage container shall not be refilled

after the sample is taken.
6.8 Gaseous samples

Gaseous samples shall be a typical specimen from the gaseous nitrogen supply. Samples shall be obtained in

accordance with one of the following.

a) By filling the sample container and storage containers at the same time, on the same manifold, and under

the same conditions and with the same procedure.

b) By withdrawing a sample from the supply container through a suitable connection into the sample

container. No pressure regulator shall be used between the supply and the sample containers. (Suitable

valves are permissible.) For safety reasons, the sample container and sampling system shall have a rated

service pressure at least equal to the pressure in the supply container.

c) By connecting the container being sampled directly to the analytical equipment using suitable pressure

regulation to prevent over-pressurizing this equipment.
6.9 Liquid samples (vaporized)

Vaporized liquid samples shall be a typical specimen from the liquid nitrogen supply. Samples shall be

obtained by flowing liquid from the supply container into or through a suitable container in which a

representative liquid sample is collected and then completely vaporized.
6.10 Rejection

When any sample of the fluid tested in accordance with Clause 7 of this part of ISO 15859 fails to conform to

the requirements specified herein, the fluid represented by the sample shall be rejected. Disposal of the

rejected fluid shall be specified by the customer.
7 Test methods
7.1 General

The supplier will ensure, by standard practice, the quality level of nitrogen. If required, alternate test methods

are described in 7.3 to 7.14. Other test methods not listed in this part of ISO 15859 are acceptable if agreed

upon between the supplier and the customer.

These tests are a single analysis or a series of analyses performed on the fluid to ensure the reliability of the

storage facility to supply the required quality level. This can be v
...

NORME ISO
INTERNATIONALE 15859-3
Première édition
2004-06-01
Systèmes spatiaux — Caractéristiques,
échantillonnage et méthodes d'essai des
fluides —
Partie 3:
Azote
Space systems — Fluid characteristics, sampling and test methods —
Part 3: Nitrogen
Numéro de référence
ISO 15859-3:2004(F)
ISO 2004
---------------------- Page: 1 ----------------------
ISO 15859-3:2004(F)
PDF – Exonération de responsabilité

Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier

peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence

autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées

acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute

responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.

Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info

du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir

l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,

veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2004

Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous

quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit

de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.

ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2004 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 15859-3:2004(F)
Avant-propos

L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de

normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée

aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du

comité technique créé à cet effet. Les organisations internationales, gouvernementales et non

gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec

la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.

Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,

Partie 2.

La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes

internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur

publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres

votants.

L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de

droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne

pas avoir identifié de tels droits de propriété et averti de leur existence.

L'ISO 15859-3 a été élaborée par le comité technique ISO/TC 20, Aéronautique et espace, sous-comité

SC 14, Systèmes spatiaux, développement et mise en œuvre.

L'ISO 15859 comprend les parties suivantes, présentées sous le titre général Systèmes spatiaux —

Caractéristiques, échantillonnage et méthodes d'essai des fluides:
 Partie 1: Oxygène
 Partie 2: Hydrogène
 Partie 3: Azote
 Partie 4: Hélium
 Partie 5: Ergols à base de tétraoxyde d’azote
 Partie 6: Monométhylhydrazine (ergol)
 Partie 7: Hydrazine (ergol)
 Partie 8: Kérosène (carburant)
 Partie 9: Argon
 Partie 10: Eau
 Partie 11: Ammoniac
 Partie 12: Dioxyde de carbone
 Partie 13: Air respirable
© ISO 2004 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 15859-3:2004(F)
Introduction

Sur une base ou sur un site de lancement spatial, les opérations sur les fluides peuvent impliquer un certain

nombre d’opérateurs et d’interfaces fournisseur/client, depuis l’usine de production du fluide jusqu’au

chargement dans le lanceur ou dans le véhicule spatial. L’objet de l’ISO 15859 est d’harmoniser les exigences

relatives à la composition, à l’échantillonnage et aux méthodes d’essai des fluides utilisés dans le

ravitaillement des lanceurs, des véhicules spatiaux et des équipements de support au sol. Les limites

spécifiées de composition des fluides ont pour objectif de définir les valeurs limites de pureté et de teneur en

impuretés des fluides à charger dans le lanceur ou dans le véhicule spatial. L’échantillonnage et les méthodes

d’essai des fluides sont destinés à être respectés par tout opérateur. Ils sont acceptables pour la vérification

des limites de composition des fluides.
iv © ISO 2004 – Tous droits réservés
---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 15859-3:2004(F)
Systèmes spatiaux — Caractéristiques, échantillonnage et
méthodes d'essai des fluides —
Partie 3:
Azote
1 Domaine d'application

La présente partie de l’ISO 15859 donne les valeurs limites de la composition de l’azote et établit les

exigences relatives à son échantillonnage et aux méthodes d’essai applicables pour vérifier sa composition.

La présente partie de l’ISO 15859 est applicable à l’azote des types et qualités suivants, utilisé aussi bien

dans le matériel embarqué que dans les installations, systèmes et équipements au sol.

 Type I: gazeux
 qualité A: purge/pressurisation,
 qualité B: respiration de l’équipage,
 qualité C,
 qualité F,
 qualité J;
 Type II: liquide
 qualité A: purge/pressurisation,
 qualité B: respiration de l’équipage,
 qualité C,
 qualité F.

La présente partie de l’ISO 15859 n’est applicable aux fluides entrant dans le système spatial que dans les

limites spécifiées ci-après.

La présente partie de l’ISO 15859 est applicable à toute opération d’échantillonnage nécessaire pour garantir

que, lorsque le fluide pénètre dans le lanceur ou dans le véhicule spatial, sa composition est conforme aux

valeurs limites définies ci-après ou aux spécifications techniques approuvées en vue d’une utilisation

particulière.
© ISO 2004 – Tous droits réservés 1
---------------------- Page: 5 ----------------------
ISO 15859-3:2004(F)
2 Références normatives

Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les

références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du

document de référence s'applique (y compris les éventuels amendements).

ISO 9000, Systèmes de management de la qualité — Principes essentiels et vocabulaire

3 Termes et définitions

Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 9000 ainsi que les

suivants s'appliquent.
3.1
méthode directe

méthode de mesurage de la pureté d’un fluide par un moyen direct, par opposition à la méthode indirecte

NOTE Un dispositif de mesure ou un analyseur peuvent être utilisés comme moyen direct pour mesurer la pureté

d’un fluide.
3.2
méthode indirecte

méthode de mesurage de la pureté d’un fluide par un moyen indirect, qui consiste à déterminer la fraction

volumique ou la fraction massique (en %) des impuretés totales et à soustraire cette quantité de 100 %

3.3
teneur totale en hydrocarbures (équivalent méthane)
équivalent en atomes de carbone simples
3.4
essai de vérification

analyse effectuée sur le fluide présent dans le conteneur ou sur un échantillon prélevé, représentatif du fluide

fourni, permettant de vérifier les limites de composition du fluide
4 Composition chimique

Sauf indication contraire dans une spécification technique applicable, la composition chimique de l’azote

fourni à l’interface du véhicule spatial doit être conforme aux valeurs limites indiquées au Tableau 1,

lorsqu’elle est vérifiée conformément aux méthodes d’essai applicables.
5 Approvisionnement

Il convient que l’azote des types et qualités spécifiés à l’Article 1 fasse l’objet d’un approvisionnement

conforme à une norme nationale applicable.
6 Échantillonnage du fluide

AVERTISSEMENT — L’azote gazeux est un asphyxiant. Tout contact du corps humain avec de l’azote

liquide peut entraîner des lésions graves. Il convient de manipuler et de stocker l’azote liquide avec

précaution afin d'éviter tout contact avec le corps humain. Il convient également d'éviter les fortes

concentrations d’azote gazeux dans les espaces confinés.
2 © ISO 2004 – Tous droits réservés
---------------------- Page: 6 ----------------------
ISO 15859-3:2004(F)
6.1 Plan

Afin de garantir que la composition du fluide respecte les valeurs limites indiquées dans la présente partie de

l’ISO 15859, il convient que tous les opérateurs concernés établissent un plan d’échantillonnage du fluide, de

la phase de production à l’interface du véhicule spatial, et que l’utilisateur final l’approuve. Les activités

d’échantillonnage et les méthodes d’essais doivent être conformes à tous les règlements et règles applicables

à cette tâche. Le plan doit préciser
 les points d’échantillonnage,
 les modes opératoires d’échantillonnage,
 la fréquence d’échantillonnage,
 la taille des échantillons,
 le nombre d’échantillons,
 les méthodes d’essai, et
 les responsabilités de chaque opérateur concerné.
Tableau 1 — Limites de composition
Valeurs limites
Composants
Type I et Type II Type I
Qualité A Qualité B Qualité C Qualité F Qualité J
Azote Fraction
99,5 99,995 99,9 99,999
volumique, %, min.
Eau µl/l, max.26,3 11,5 5,7 15 10
Teneur totale en hydrocarbures
µl/l, max. 58,3 5,0 5,0 25 
en équivalent méthane (CH )
Oxygène µl/l, max. 5 000 50 20 1 000 5
e e e
Hydrogène µl/l 0,5
µl/l e e
Argon 20 2,0 
µl/l, max. e e
Dioxyde de carbone 5,0 5,0 
e e
µl/l, max.
Monoxyde de carbone 5,0 5,0 
Hydrocarbures aromatiques en
µl/l, max.  0,5   
équivalent benzène
Hydrocarbures halogénés µl/l, max.
 1,0   
µl/l, max.  0,1   
Hydrocarbures chlorés
µl/l, max.
Oxyde nitreux  1,0   
Odeur
 Aucune   
mg/l,
Matière particulaire
  1,0 1,0 
max.
µl/l, max. 5 000 100 50 1 000 10
Total d’impuretés

L’azote (en pourcentage) contient des traces de néon et d’hélium et de faibles quantités d’argon.

Si nécessaire.
S’applique seulement à l’azote de type II (liquide).

Somme de tous les pourcentages d’eau, d’hydrocarbures, d’oxygène, d’hydrogène, et, le cas échéant, de monoxyde de

carbone, de dioxyde de carbone et d’argon.
Pas de limite pour cette qualité.
99,99 % par la méthode indirecte et 95,0 % par méthode directe.

Uniquement pour un essai au sol «Système de contrôle de l’environnement et support de vie» (SCESV).

© ISO 2004 – Tous droits réservés 3
---------------------- Page: 7 ----------------------
ISO 15859-3:2004(F)
6.2 Responsabilités relatives à l’échantillonnage

Sauf indication contraire dans une spécification technique applicable, l’azote fourni à l’interface du véhicule

spatial doit être échantillonné et contrôlé par le fournisseur chargé d’approvisionner le véhicule spatial en

azote. Le fournisseur peut utiliser ses propres ressources ou toute autre ressource appropriée pour effectuer

les essais de vérification indiqués dans la présente partie de l’ISO 15859, sauf instruction contraire de la part

du client.
6.3 Points d’échantillonnage

Sauf indication contraire, l’échantillonnage doit être effectué sur le site de stockage du fluide ou à l’interface

du véhicule spatial.
6.4 Fréquence d’échantillonnage

L’échantillonnage doit être effectué chaque année ou conformément au calendrier approuvé par le fournisseur

et le client.
6.5 Taille des échantillons

La quantité présente dans une seule éprouvette doit suffire pour caractériser les valeurs limites. Si un seul

échantillon ne contient pas une quantité suffisante de fluide pour effectuer toutes les analyses nécessaires à

l’essai de vérification avec la qualité requise, des échantillons supplémentaires doivent être prélevés dans les

mêmes conditions.
6.6 Nombre d’échantillons

Le nombre d’échantillons doit être conforme à l’une des deux exigences suivantes:

a) un échantillon par conteneur de stockage;
b) nombre d’échantillons approuvé par le fournisseur et le client.
6.7 Conteneur de stockage

Sauf indication contraire dans le plan d’échantillonnage applicable, le conteneur de stockage du fluide ne doit

pas être rempli à nouveau après prélèvement de l’échantillon.
6.8 Échantillons gazeux

Les échantillons gazeux doivent être représentatifs de la fourniture en azote gazeux. Les échantillons doivent

être prélevés conformément à l’une des techniques suivantes.

a) En remplissant simultanément l’éprouvette et les conteneurs de stockage, sur le même manifold, dans

les mêmes conditions et selon le même mode opératoire.

b) En prélevant un échantillon dans le conteneur de fourniture par le biais d’un branchement adéquat sur

l’éprouvette. Aucun régulateur de pression ne doit être utilisé entre le conteneur de fourniture et

l’éprouvette (des valves adaptées sont acceptées). Pour des raisons de sécurité, la pression d’utilisation

dans l’éprouvette et dans le système d’échantillonnage doit être au moins égale à la pression du

conteneur de fourniture.

c) En branchant le conteneur dont le contenu est à analyser directement sur le matériel d’analyse, en

régulant la pression afin d’éviter que ce matériel ne subisse de surpression.
4 © ISO 2004 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO 15859-3:2004(F)
6.9 Échantillons liquides (vaporisés)

Les échantillons liquides vaporisés doivent être représentatifs de la fourniture en azote liquide. Les

échantillons doivent être obtenus en faisant couler le liquide depuis le conteneur de fourniture dans (ou à

travers) un conteneur adapté, où l’on prélève les échantillons liquides représentatifs qui sont ensuite

complètement vaporisés.
6.10 Rejet

Si un échantillon du fluide soumis aux essais conformément à l'Article 7 n’est pas conforme aux exigences

spécifiées dans la présente partie de l’ISO 15859, le fluide représenté par l’échantillon doit être rejeté.

L'élimination du fluide rejeté doit être spécifiée par le client.
7 Méthodes d'essai
7.1 Généralités

Le fournisseur doit s'assurer, par des pratiques courantes, du niveau de qualité de l’azote. Si nécessaire, des

méthodes d'essai de remplacement sont décrites en 7.3 à 7.14. D’autres méthodes d'essai, non mentionnées

dans la présente partie de l’ISO 15859, s
...

Questions, Comments and Discussion