Non-destructive testing — Leak testing — Calibration of reference leaks for gases

ISO 20486:2017 specifies the calibration of those leaks that are used for the adjustment of leak detectors for the determination of leakage rate in everyday use. One type of calibration method is a comparison with a reference leak. In this way, the leaks used for routine use become traceable to a primary standard. In other calibration methods, the value of vapour pressure was measured directly or calculated over a known volume. The comparison procedures are preferably applicable to helium leaks, because this test gas can be selectively measured by a mass spectrometer leak detector (MSLD) (the definition of MSLD is given in ISO 20484). Calibration by comparison (see methods A, As, B and Bs below) with known reference leaks is easily possible for leaks with reservoir and leakage rates below 10−7 Pa·m3/s. Figure 1 gives an overview of the different recommended calibration methods.

Essais non destructifs — Contrôle d'étanchéité — Étalonnage des fuites de référence des gaz

ISO 20486:2017 spécifie l'étalonnage des fuites utilisées dans le réglage des détecteurs de fuites et la détermination des flux de fuite, dans le cadre d'un usage quotidien. Un type de méthode d'étalonnage est une comparaison avec une fuite de référence. Ainsi, les fuites faisant l'objet d'un usage courant deviennent traçables par rapport à un étalon primaire. Dans d'autres méthodes d'étalonnage, la valeur de la pression de vapeur était mesurée directement ou calculée sur un volume connu. Les modes opératoires d'étalonnage par comparaison sont de préférence applicables aux fuites d'hélium, car ce gaz d'essai peut être mesuré individuellement au moyen d'un détecteur de fuites à spectromètre de masse (DFSM) (la définition de DFSM est donnée dans l'ISO 20484). L'étalonnage par comparaison (voir méthodes A, As, B et Bs ci-dessous) qui utilise des fuites de référence connues est facilement applicable aux fuites de réservoir et à celles dont les flux de fuite sont inférieurs à 10−7 Pa·m3/s.

General Information

Status
Published
Publication Date
13-Dec-2017
Current Stage
9060 - Close of review
Start Date
03-Jun-2028
Ref Project

Relations

Buy Standard

Standard
ISO 20486:2017 - Non-destructive testing -- Leak testing -- Calibration of reference leaks for gases
English language
32 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 20486:2017 - Essais non destructifs -- Contrôle d'étanchéité -- Étalonnage des fuites de référence des gaz
French language
33 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 20486
First edition
2017-12
Non-destructive testing — Leak
testing — Calibration of reference
leaks for gases
Essais non destructifs — Contrôle d'étanchéité — Étalonnage des
fuites de référence des gaz
Reference number
ISO 20486:2017(E)
©
ISO 2017

---------------------- Page: 1 ----------------------
ISO 20486:2017(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2017, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 20486:2017(E)

Contents Page
Foreword .v
1 Scope . 1
2 Normative references . 2
3 Terms and definitions . 2
4 Nominal leakage rates . 3
5 Classification of leaks . 3
5.1 Permeation leak . 3
5.2 Conductance leaks . 3
5.2.1 Capillary leak . 3
5.2.2 Aperture leak (orifice) . 4
5.2.3 Compressed powder leak . 4
6 Calibration by comparison . 4
6.1 Methods A, A , B and B .
s s 4
6.2 Applicability of comparison methods . 4
6.3 Preparation of leaks and apparatus . 5
6.3.1 Leak detector . 5
6.3.2 Connection to the leak detector . 5
6.3.3 Temperature accommodation . 7
6.4 Measurement . 7
6.4.1 Set-up . 7
6.4.2 General measurement sequence . 7
6.5 Evaluation for methods A, A , B and B (Comparison) . 8
s s
6.5.1 Determination of leakage rate . 8
6.5.2 Influence factors to measurement uncertainty . 9
7 Volumetric calibration.10
7.1 Direct flow (Method C) .10
7.1.1 General.10
7.1.2 Equipment .10
7.1.3 Preparation of leaks and apparatus .10
7.1.4 Measurement .11
7.1.5 Evaluation for Method C (direct flow measurement) .13
7.2 Leak measurement under water (Method D) .14
7.2.1 General.14
7.2.2 Equipment .14
7.2.3 Preparation of leaks and apparatus .14
7.2.4 Measurement .15
7.2.5 Evaluation for Method D .16
7.2.6 Influence factors to measurement uncertainty .17
7.3 Calibration by (volumetric) gas meter (Method E) .17
7.3.1 General.17
7.3.2 Equipment .18
7.3.3 Preparation of leaks and apparatus .18
7.3.4 Measurement .18
7.3.5 Evaluation for Method E (gas meter) .18
7.3.6 Influence factors to measurement uncertainty .19
7.4 Calibration by pressure change in a known volume (Method F) .19
7.4.1 General.19
7.4.2 Preparation of leaks and apparatus .20
7.4.3 Measurement .22
7.4.4 Special situation in vacuum chambers .23
7.4.5 Evaluation for Method F (pressure change) .25
7.4.6 Influence factors to measurement uncertainty .25
© ISO 2017 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 20486:2017(E)

7.5 Calibration by volume change at constant pressure (Method G) .26
7.5.1 Equipment .26
7.5.2 Preparation of leaks and apparatus .26
7.5.3 Measurement .26
7.5.4 Evaluation for Method G (volume change at constant pressure).27
8 General influences .28
9 Report .28
10 Labelling of reference leaks .29
11 Handling of reference leaks .29
11.1 General .29
11.2 Permeation leaks (normally with reservoir fitted the leak outlet) .29
11.3 Conductance leaks (normally without reservoir) .29
Annex A (informative) Calculation of leakage rate decrease due to tracer gas depletion in
the reservoir .30
Bibliography .32
iv © ISO 2017 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 20486:2017(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 135, Non-destructive testing,
Subcommittee SC 6, Leak testing.
© ISO 2017 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 20486:2017(E)
Non-destructive testing — Leak testing — Calibration of
reference leaks for gases
1 Scope
This document specifies the calibration of those leaks that are used for the adjustment of leak detectors
for the determination of leakage rate in everyday use. One type of calibration method is a comparison
with a reference leak. In this way, the leaks used for routine use become traceable to a primary standard.
In other calibration methods, the value of vapour pressure was measured directly or calculated over a
known volume.
The comparison procedures are preferably applicable to helium leaks, because this test gas can be
selectively measured by a mass spectrometer leak detector (MSLD) (the definition of MSLD is given in
ISO 20484).
Calibration by comparison (see methods A, A , B and B below) with known reference leaks is easily
s s
−7 3
possible for leaks with reservoir and leakage rates below 10 Pa·m /s.
Figure 1 gives an overview of the different recommended calibration methods.
a) Calibration by comparison
© ISO 2017 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 20486:2017(E)

b) Calibration by direct measurement
Key
3
X leakage rate in Pa·m /s C Method C
A Method A D Method D
B Method B E Method E
A Method A F Method F
s s
B Method B G Method G
s s
normal range possible range
Figure 1 — Calibration ranges
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 20484, Non-destructive testing — Leak testing — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 20484 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
2 © ISO 2017 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 20486:2017(E)

3.1
unknown leak
leak having a stable and repeatable leakage rate of known order of magnitude that can be determined
by calibration
3.2
reference leak
calibrated leak which may be used to calibrate another leak
Note 1 to entry: The uncertainty of the reference leak is lower than the required uncertainty of the leak to be
calibrated.
3.3
calibration
set of operations which establish, under specified conditions, the relationship between leakage rate
values represented by an unknown leak and the corresponding known values of the leakage rate
Note 1 to entry: In the case of calibration by comparison, the known values of the leakage rate are represented by
a reference leak.
Note 2 to entry: Normally, the result of a calibration is given as the leakage rate value for the reference leak with
a standard uncertainty.
3.4
nominal leakage rate
leakage rate of a leak calculated for specified reference conditions
3
Note 1 to entry: In leak detection, leakage rates are commonly given in units of pV-throughput (Pa·m /s, mbar l/s,
3
Std cm /min). These are only a precise measure of gas flow if the temperature is given and kept constant. Flow
units such as mass flow (g/y) or molar flow (mol/s) are sometimes used to overcome this problem.
4 Nominal leakage rates
Calibrated leaks are only comparable under the same reference conditions. Nominal leakage rates shall
be used for comparison. Recommended reference conditions are:
— Ambient temperature: 20 °C
— Atmospheric exhaust pressure: 1 000 mbar
— Vacuum exhaust pressure: < 100 mbar
The reference inlet pressure is given by the leak reservoir pressure or the application requirement.
5 Classification of leaks
5.1 Permeation leak
This type of leak is normally made with a tracer gas reservoir. It has the best long-term stability but an
appreciable temperature coefficient (approximately 3,5 %/K). Typical leakage rates are in the range
−10 3 −4 3
from 10 Pa·m /s to 10 Pa·m /s.
5.2 Conductance leaks
5.2.1 Capillary leak
This type of leak is available with or without a tracer gas reservoir. It has a low temperature coefficient
(approximately 0,3 %/K) but easily blocks if not handled with care. Typical leakage rates are greater
−7 3
than 10 Pa·m /s.
© ISO 2017 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 20486:2017(E)

5.2.2 Aperture leak (orifice)
Orifices are seldom used as reference leaks in practice, as they are difficult to manufacture and even
more prone to blocking than capillaries.
NOTE Critical flow orifices are a form of aperture leak that is commonly found in industry, but are out of the
scope of this document.
5.2.3 Compressed powder leak
This type of leak uses metal powder compressed into a tube. They are usually offered without reservoir.
They are used for routine check of the sensitivity of leak detectors but they are not stable enough to be
used as calibrated leaks. Their suitability depends on how well controlled the storage and operating
conditions are, and on the required uncertainty.
6 Calibration by comparison
6.1 Methods A, A , B and B
s s
There are two ways of calibrating leaks by comparison with known reference leaks. Both methods
require the knowledge of the order of magnitude of the leakage rate to be measured. The methods
differ in using one or two reference leaks, resulting in different uncertainties of measurement. In the
following, the two methods are designated as A and B:
— Method A: Comparison to one reference leak normally with a leakage rate of the same order of
magnitude, calibration with vacuum method.
— Method A : Comparison to one reference leak normally with a leakage rate of the same order of
s
magnitude, calibration with sniffing method.
— Method B: Comparison to two reference leaks with leakage rates normally lying on either side of the
unknown leakage rate, calibration with vacuum method.
— Method B : Comparison to two reference leaks with leakage rates normally lying on either side of
s
the unknown leakage rate. Calibration with sniffing method.
Method A is most suitable for use on site as only one reference leak is used. It is generally applicable
but is most reliable when the leakage rate of the unknown is close to that of the reference leak. This is
because the measurement uncertainty is directly dependent on the linearity of the leak detector in use.
As the linearity error cannot be measured independently, it needs to be estimated. To keep the linearity
error small, the operating characteristics of leak detector should not change during calibration (e.g.
automatic ranging should be disabled).
For more precise calibrations, where a more reliable measure of uncertainty is required or if a reference
leak with a leakage rate close to the unknown is not available Method B should be used. By the use of
two reference leaks, the non-linearity of the leak detector is accounted for.
6.2 Applicability of comparison methods
Since comparison of leaks is not a fundamental measurement method, it relies on the stability of the
transfer device and cleanliness of the ambient gas atmosphere. Moreover, the temperature dependence
of the reference and unknown leaks shall be taken into account.
The most stable and clean conditions are achieved for leaks with exhaust into vacuum and a mass
spectrometer leak detector as transfer device measuring the partial pressure generated by the leaks in
vacuum. Under these conditions, all interfering background gases are reduced to a minimum so that the
zero point of the transfer device is defined and stable.
4 © ISO 2017 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 20486:2017(E)

For leaks with exhaust into the atmosphere and measurement by sniffing gas, more conditions shall be
controlled. These are:
— the background level of tracer gas shall be as low as possible and as stable as possible;
— the total gas flow rate of the sniffer shall be high enough to take up the total tracer gas flow out of
the leak;
— the aspiration of the sniffer (the coupling to the leak exhaust) shall be of suitable geometry to make
sure that the atmospheric gas flow across the leak exhaust takes up the whole tracer gas flow from
the leak opening.
As a consequence, the measurement uncertainty is appreciably higher for sniffer leaks than for
vacuum leaks.
Methods by comparison are therefore applicable but not preferable for the calibration of sniffer leaks
(with exhaust to atmosphere).
6.3 Preparation of leaks and apparatus
6.3.1 Leak detector
The leak detector (LD) used as a transfer device shall be set up according to the manufacturer’s manual.
The warm-up time shall be at least 2 h.
6.3.2 Connection to the leak detector
The reference and unknown leaks are connected to the leak detector used as the transfer instrument.
The connection shall be kept continuously until the measurement is completed. This includes thermal
[1]
accommodation .
In the case of vacuum leaks, they are connected to the inlet flange and pumped with their valves (if any)
open for at least 30 min to remove any tracer gas that can have accumulated in seals or valves. For the
calibration of more than one leak, a separate pumping system and set of valves is useful to keep all the
leaks pumped until they are measured.
© ISO 2017 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 20486:2017(E)

Key
1 transfer device (leak detector)
2 test port
3 rig
4 leaks to be calibrated and reference leak
5 hoods for thermal stability
Figure 2 — Coupling of leaks to the leak detector
In the case of sniffer leaks, the connection to the leak detector sniffing tip is made by an adapter which
makes a tight connection to the leak outlet and enables atmospheric air to be continuously sucked
across the leak exhaust via an air inlet (see Key item 3 in Figure 2), so that the whole leak gas flow
is taken up by the sniffer tip. The air inlet opening shall not throttle the free flow of air to maintain
atmospheric pressure in front of the sniffer tip. See Figure 3.
6 © ISO 2017 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 20486:2017(E)

Key
1 gasket 4 test leak with leak opening
2 sniffer tip 5 adapter body with gasket
3 air inlet 6 sniffer opening with cross-wise slot
Figure 3 — Example for a coupling adapter for sniffer leaks
6.3.3 Temperature accommodation
The unknown leak and the reference leak(s) for the comparison shall be stored in the same room where
the test is to be carried out for at least 12 h to allow for temperature equilibration (an air-conditioned
room is not necessary if there are no rapid temperature changes. Because of temperature fluctuations,
an air-conditioning system can even increase the measurement uncertainty). Vacuum leaks,
connected to the LD shall be pumped during the phase of thermal accommodation. After temperature
accommodation, to prevent any temperature changes during measurement, thermally insulating hoods
(made of plastic foam or similar material) should be put over the leaks.
6.4 Measurement
6.4.1 Set-up
It is important to ensure that the effective pumping speed at the leak detector inlet for vacuum leaks,
respectively the sniffer gas flow for overpressure leaks, is not changed during the measurements.
If possible, either with the leak detector or in an auxiliary device, a long averaging time may be used to
decrease the statistical measurement uncertainty.
All the measurement instruments should be adjusted in such a way that they give nearly full-scale
deflections for the biggest leak.
6.4.2 General measurement sequence
Generally, each reading shall be obtained only after the signal of the transfer instrument has stabilized.
A sufficient number of readings shall be taken to achieve the lowest possible statistical uncertainty.
© ISO 2017 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 20486:2017(E)

This way, a measure of statistical deviation can also be found. The general sequence of measurements
is as follows:
a) zero signal determination: all valves closed for vacuum leaks, respectively sniffer tip in pure
ambient air for sniffing leaks;
b) connect reference leak No. 1, wait for steady flow and measure the resulting output signal
(Method A, A , B and B );
s s
c) disconnect reference leak No.1;
d) connect reference leak No. 2, wait for steady flow and measure the resulting output signal (only
Method B and B );
s
e) disconnect reference leak No. 2;
f) connect unknown leaks, wait for steady flow and measure the resulting output signal;
g) repeat steps a) to f) at least three times.
Leak valves should be kept closed for as short a time as possible to prevent extensive helium
accumulation resulting in long equilibration time.
6.5 Evaluation for methods A, A , B and B (Comparison)
s s
6.5.1 Determination of leakage rate
6.5.1.1 Method A and A : Result of comparison to one reference leak
s
Formula (1a) is used to calculate the unknown leakage rate, Q , from the reading, R , of the reference
u ref
leak with leakage rate, Q , and the reading, R , of the unknown leak:
ref u
R
u
QQ= (1a)
uref
R
ref
This formula is only valid, if the temperature coefficients and the temperatures of all leaks are equal.
Otherwise, Formula (1b) shall be used:
 
RT1+⋅α Δ
()
uref ref
QQ=⋅ (1b)
 
uref
RT1+⋅α Δ
()
 
refu u
 
where
Q , Q are the leakage rates of the reference and unknown leak, respectively;
ref u
R , the readings of the reference and unknown leak, respectively;
ref Ru
α , α are the temperature coefficients of the reference and unknown leak, respectively;
ref u
ΔT , ΔT are the departures of the temperature of the leaks from the reference temperature of
ref u
the reference and unknown leak, respectively.
The readings can be in any consistent units, as only ratios are considered.
NOTE 1 The readings (R and R ) are obtained from the leak detector display as the difference of the output
ref u
signals with leak connected and disconnected (respectively, valve opened and closed).
NOTE 2 The temperature coefficient of the reference leak is normally stated. If the temperature coefficient of
the unknown leak is not given, it can be assumed that it is approximately 3,5 %/K for a quartz permeation leak,
and 0,3 %/K for conductance type leaks in viscous flow mode.
8 © ISO 2017 – All rights reserv
...

NORME ISO
INTERNATIONALE 20486
Première édition
2017-12
Essais non destructifs — Contrôle
d'étanchéité — Étalonnage des fuites
de référence des gaz
Non-destructive testing — Leak testing — Calibration of reference
leaks for gases
Numéro de référence
ISO 20486:2017(F)
©
ISO 2017

---------------------- Page: 1 ----------------------
ISO 20486:2017(F)

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2017, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 20486:2017(F)

Sommaire Page
Avant-propos .v
1 Domaine d'application . 1
2 Références normatives . 2
3 Termes et définitions . 2
4 Flux de fuite nominaux . 3
5 Classification des fuites . 3
5.1 Fuite par perméation . 3
5.2 Défaut d'étanchéité par conductance . 4
5.2.1 Capillaire . 4
5.2.2 Orifice en paroi mince (orifice) . 4
5.2.3 Fuite de métal fritté . 4
6 Étalonnage par comparaison . 4
6.1 Méthodes A, A , B et B .
s s 4
6.2 Applicabilité des méthodes de comparaison . 5
6.3 Préparation des fuites et appareillage . 5
6.3.1 Détecteur de fuites . 5
6.3.2 Raccordement au détecteur de fuites . 5
6.3.3 Adaptation de la température . 7
6.4 Mesurage . 7
6.4.1 Réglage . 7
6.4.2 Ordre général des opérations de mesurage . 7
6.5 Évaluation pour les méthodes A, A , B et B (comparaison) . 8
s s
6.5.1 Détermination du flux de fuite . 8
6.5.2 Facteurs d'influence pour l'incertitude de mesure . 9
7 Étalonnage volumétrique .10
7.1 Débit direct (méthode C) .10
7.1.1 Généralités .10
7.1.2 Équipement .10
7.1.3 Préparation des fuites et appareillage .10
7.1.4 Mesurage .11
7.1.5 Évaluation pour la méthode C (mesurage direct du débit) .13
7.2 Mesurage d'une fuite sous l'eau (méthode D) .14
7.2.1 Généralités .14
7.2.2 Équipement .14
7.2.3 Préparation des fuites et appareillage .14
7.2.4 Mesurage .15
7.2.5 Évaluation pour la méthode D .16
7.2.6 Facteurs d'influence pour l'incertitude de mesure .17
7.3 Étalonnage à l'aide d'un compteur (volumétrique) à gaz (méthode E) .17
7.3.1 Généralités .17
7.3.2 Équipement .18
7.3.3 Préparation des fuites et appareillage .18
7.3.4 Mesurage .18
7.3.5 Évaluation pour la méthode E (compteur à gaz).18
7.3.6 Facteurs d'influence pour l'incertitude de mesure .19
7.4 Étalonnage par variation de pression dans un volume connu (méthode F) .19
7.4.1 Généralités .19
7.4.2 Préparation des fuites et appareillage .20
7.4.3 Mesurage .22
7.4.4 Situation particulière dans les chambres à vide .23
7.4.5 Évaluation pour la méthode F (variation de pression) .25
7.4.6 Facteurs d'influence pour l'incertitude de mesure .25
© ISO 2017 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 20486:2017(F)

7.5 Étalonnage par variation du volume à pression constante (méthode G) .26
7.5.1 Équipement .26
7.5.2 Préparation des fuites et appareillage .26
7.5.3 Mesurage .26
7.5.4 Évaluation pour la méthode G (variation du volume à pression constante).27
8 Influences générales .28
9 Rapport.29
10 Étiquetage des fuites de référence .29
11 Manipulation des fuites de référence .29
11.1 Généralités .29
11.2 Fuites par perméation (en général avec un réservoir fixé à l'orifice de sortie de la fuite) 30
11.3 Fuites par conductance (en général sans réservoir) .30
Annexe A (informative) Calcul de la diminution du flux de fuite due à une déplétion du gaz
traceur dans le réservoir .31
Bibliographie .33
iv © ISO 2017 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 20486:2017(F)

Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes
nationaux de normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est
en général confiée aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l'ISO participent également aux travaux.
L'ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d'approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L'attention est attirée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l'élaboration du document sont indiqués dans l'Introduction et/ou dans la liste des déclarations de
brevets reçues par l'ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l'ISO liés à l'évaluation de la conformité, ou pour toute information au sujet de l'adhésion
de l'ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www.iso.org/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 135, Essais non destructifs, sous-
comité SC 6, Contrôle par détection de fuites.
© ISO 2017 – Tous droits réservés v

---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 20486:2017(F)
Essais non destructifs — Contrôle d'étanchéité —
Étalonnage des fuites de référence des gaz
1 Domaine d'application
Le présent document spécifie l'étalonnage des fuites utilisées dans le réglage des détecteurs de fuites et
la détermination des flux de fuite, dans le cadre d'un usage quotidien. Un type de méthode d'étalonnage
est une comparaison avec une fuite de référence. Ainsi, les fuites faisant l'objet d'un usage courant
deviennent traçables par rapport à un étalon primaire. Dans d'autres méthodes d'étalonnage, la valeur
de la pression de vapeur était mesurée directement ou calculée sur un volume connu.
Les modes opératoires d'étalonnage par comparaison sont de préférence applicables aux fuites d'hélium,
car ce gaz d'essai peut être mesuré individuellement au moyen d'un détecteur de fuites à spectromètre
de masse (DFSM) (la définition de DFSM est donnée dans l'ISO 20484).
L'étalonnage par comparaison (voir méthodes A, A , B et B ci-dessous) qui utilise des fuites de référence
s s
connues est facilement applicable aux fuites de réservoir et à celles dont les flux de fuite sont inférieurs
−7 3
à 10 Pa·m /s.
La Figure 1 donne un aperçu des différentes méthodes d'étalonnage recommandées.
a) Étalonnage par comparaison
© ISO 2017 – Tous droits réservés 1

---------------------- Page: 6 ----------------------
ISO 20486:2017(F)

b) Étalonnage par mesurage direct
Légende
3
X flux de fuite en Pa·m /s C Méthode C
A Méthode A D Méthode D
B Méthode B E Méthode E
A Méthode A F Méthode F
s s
B Méthode B G Méthode G
s s
plage normale plage possible
Figure 1 — Plages d'étalonnage
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les
références non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
ISO 20484, Essais non destructifs — Contrôle d’étanchéité — Vocabulaire
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de l'ISO 20484 ainsi que les suivants
s'appliquent.
L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— IEC Electropedia: disponible à l’adresse http://www.electropedia.org/
— ISO Online browsing platform: disponible à l’adresse https://www.iso.org/obp
2 © ISO 2017 – Tous droits réservés

---------------------- Page: 7 ----------------------
ISO 20486:2017(F)

3.1
fuite inconnue
fuite ayant un flux de fuite stable et répétable d’ordre de grandeur connu qui peut être déterminé par
étalonnage
3.2
fuite de référence
fuite calibrée pouvant être utilisée pour étalonner une autre fuite
Note 1 à l'article: L'incertitude de la fuite de référence est inférieure à l'incertitude requise de la fuite à étalonner.
3.3
étalonnage
ensemble des opérations établissant, dans des conditions spécifiées, la relation entre les valeurs d'un
flux de fuite représentées par une fuite inconnue et les valeurs correspondantes connues du flux de fuite
Note 1 à l'article: Pour un étalonnage par comparaison, les valeurs connues du flux de fuite sont représentées par
une fuite de référence.
Note 2 à l'article: Le résultat de l'étalonnage est normalement donné comme étant la valeur du flux de fuite pour
la fuite de référence avec une incertitude-type.
3.4
flux de fuite nominal
flux de fuite d'une fuite, calculé pour des conditions de référence spécifiées
Note 1 à l'article: Dans la détection de fuites, les flux de fuite sont couramment donnés en unités de flux gazeux
3 3
pV (Pa·m /s, mbar l/s, Std cm /min). Toutefois, ces unités constituent une mesure précise du débit gazeux
uniquement lorsque la température est donnée et maintenue constante. Des unités de débit telles que le débit-
masse (g/y) ou le débit molaire (mol/s) sont parfois utilisées pour pallier ce problème.
4 Flux de fuite nominaux
Des fuites calibrées sont comparables uniquement dans les mêmes conditions de référence. Les
flux de fuite nominaux doivent être utilisés pour la comparaison. Les conditions de référence
recommandées sont:
— Température ambiante: 20 °C
— Pression de sortie dans l'atmosphère: 1 000 mbar
— Pression de sortie sous vide: < 100 mbar
La pression d'entrée de référence est donnée par la pression du réservoir de fuite ou l'exigence de
l'application.
5 Classification des fuites
5.1 Fuite par perméation
Ce type de fuite est habituellement produit avec un réservoir de gaz traceur. Elle présente la meilleure
stabilité à long terme, mais son coefficient de température n'est pas négligeable (environ 3,5 %/K). Les
−10 3 −4 3
flux de fuite types sont compris dans la plage de 10 Pa·m /s à 10 Pa·m /s.
© ISO 2017 – Tous droits réservés 3

---------------------- Page: 8 ----------------------
ISO 20486:2017(F)

5.2 Défaut d'étanchéité par conductance
5.2.1 Capillaire
Ce type de fuite est disponible avec ou sans réservoir de gaz traceur. Elle a un faible coefficient de
température (environ 0,3 %/K), mais peut être facilement obstruée si elle n'est pas manipulée avec
−7 3
soin. Les flux de fuite types sont supérieurs à 10 Pa·m /s.
5.2.2 Orifice en paroi mince (orifice)
Les orifices sont rarement utilisés comme fuites de référence dans la pratique, car ils sont difficiles à
réaliser et encore plus prédisposés à l'obstruction que les capillaires.
NOTE Les orifices de débit critique sont une forme d'orifice en paroi mince couramment rencontrée dans
l'industrie, mais ils ne relèvent pas du domaine d'application du présent document.
5.2.3 Fuite de métal fritté
Ce type de fuite utilise de la poudre métallique comprimée dans un tube. Elle est généralement
disponible sans réservoir et utilisée pour les contrôles de routine de la sensibilité des détecteurs de
fuites. Toutefois, sa stabilité n'est pas suffisante pour une utilisation en tant que fuite d'étalonnage. Son
aptitude à l'emploi dépend du niveau de contrôle des conditions d'entreposage et de fonctionnement, et
de l'incertitude requise.
6 Étalonnage par comparaison
6.1 Méthodes A, A , B et B
s s
Deux méthodes permettent de pratiquer l'étalonnage des fuites par comparaison avec des fuites de
référence connues. Ces deux méthodes exigent de connaître l’ordre de grandeur du flux de fuite à mesurer.
Elles se différencient par l'utilisation d'une ou deux fuites de référence, ce qui conduit à des incertitudes
de mesure différentes. Dans la suite du document, les deux méthodes sont désignées par A et B:
— Méthode A: comparaison avec une fuite de référence, dont le flux est normalement du même ordre
de grandeur, étalonnage par une méthode sous vide.
— Méthode A : comparaison avec une fuite de référence, dont le flux est normalement du même ordre
s
de grandeur, étalonnage par une méthode de reniflage.
— Méthode B: comparaison avec deux fuites de référence, dont les flux sont normalement situés de
part et d'autre du flux de fuite inconnu, étalonnage par une méthode sous vide.
— Méthode B : comparaison avec deux fuites de référence, dont les flux sont normalement situés de
s
part et d'autre du flux de fuite inconnu, étalonnage par une méthode de reniflage.
La méthode A est plus adaptée à une utilisation sur site, car elle n’utilise qu’une fuite de référence.
Toutefois, bien qu’elle soit généralement applicable, sa fiabilité est accrue lorsque le flux de fuite
inconnu est proche de celui de la fuite de référence. Ce phénomène est dû au fait que l’incertitude de
mesure dépend directement de la linéarité du détecteur de fuites utilisé. Étant donné que l’erreur de
linéarité ne peut pas être mesurée indépendamment, elle doit être estimée. Afin de maintenir une faible
erreur de linéarité, il convient que les caractéristiques de fonctionnement du détecteur de fuites ne
soient pas modifiées au cours de l’étalonnage (par exemple, il convient de mettre hors service le réglage
automatique de zéro).
Pour une plus grande précision d’étalonnage, lorsqu’une mesure d’incertitude plus fiable est requise
ou si une fuite de référence dont le flux est proche de celui de la fuite inconnue ne peut être obtenue,
il convient d’utiliser la méthode B. La non-linéarité du détecteur de fuites est prise en compte par
l'utilisation de deux fuites de référence.
4 © ISO 2017 – Tous droits réservés

---------------------- Page: 9 ----------------------
ISO 20486:2017(F)

6.2 Applicabilité des méthodes de comparaison
Étant donné que la comparaison de fuites n'est pas une méthode de mesure fondamentale, elle repose
sur la stabilité du dispositif de transfert et la propreté de l'atmosphère gazeuse ambiante. De plus, la
dépendance vis-à-vis de la température des fuites de référence et inconnues doit être prise en compte.
Les conditions les plus stables et les plus propres sont obtenues pour des fuites déchargeant dans le
vide et avec un détecteur de fuites à spectromètre de masse comme dispositif de transfert mesurant
la pression partielle générée par les fuites dans le vide. Dans ces conditions, tous les gaz de fond
interférents sont réduits au minimum de sorte que le zéro du dispositif de transfert soit défini et stable.
Pour des fuites déchargeant dans l'atmosphère et un mesurage par reniflage du gaz, des conditions
supplémentaires doivent être contrôlées, à savoir:
— la concentration de fond en gaz traceur doit être aussi faible et aussi stable que possible;
— le débit total de gaz de la sonde de reniflage doit être suffisamment élevé pour prélever la totalité du
flux de gaz traceur sortant du défaut d'étanchéité;
— l'aspiration de la sonde de reniflage (raccord avec la sortie de la fuite) doit avoir une géométrie
appropriée pour s'assurer que le flux de gaz déchargeant dans l'atmosphère par la sortie de la fuite
contient la totalité du flux de gaz traceur provenant de l'ouverture de la fuite.
Par conséquent, l'incertitude de mesure est nettement plus élevée pour des fuites détectées par
reniflage que pour des fuites détectées sous vide.
Les méthodes par comparaison sont donc applicables, mais non recommandées pour l'étalonnage des
fuites détectées par reniflage (avec décharge dans l'atmosphère).
6.3 Préparation des fuites et appareillage
6.3.1 Détecteur de fuites
Le détecteur de fuite (DF) utilisé comme dispositif de transfert doit être réglé conformément aux
instructions du manuel du fabricant. La durée de mise en condition doit être d’au moins 2 h.
6.3.2 Raccordement au détecteur de fuites
Les fuites de référence et les fuites inconnues sont raccordées au détecteur de fuites utilisé comme
instrument de transfert. Le raccordement doit être maintenu continuellement jusqu'à ce que le
[1]
mesurage soit terminé. Cela inclut l'adaptation de la température .
Dans le cas de fuites détectées sous vide, elles sont raccordées à la bride d'aspiration et pompées pendant
au moins 30 min, vannes ouvertes (s’il y en a), afin d’extraire tout le gaz traceur ayant pu s’accumuler
dans les joints ou les vannes. Pour l’étalonnage de deux fuites au moins, un système de pompage séparé
et un jeu de vannes sont utiles pour retenir les fuites pompées jusqu’à leur mesurage.
© ISO 2017 – Tous droits réservés 5

---------------------- Page: 10 ----------------------
ISO 20486:2017(F)

Légende
1 dispositif de transfert (détecteur de fuites)
2 prise d'essai
3 banc
4 fuites à étalonner et fuite de référence
5 poches isolantes pour la stabilité thermique
Figure 2 — Raccordement des fuites au détecteur de fuites
Dans le cas de fuites détectées par reniflage, le raccordement à la sonde de reniflage du détecteur
de fuites est réalisé à l'aide d'un adaptateur assurant un raccord étanche avec la sortie de la fuite et
permettant à l'air ambiant d'être continuellement aspiré à travers la sortie de la fuite via une entrée
d'air (voir légende 3 à la Figure 2) de manière que la totalité du flux de gaz de la fuite soit prélevée par
la sonde de reniflage. L'ouverture d'entrée d'air ne doit pas entraver le libre écoulement de l'air pour
maintenir la pression atmosphérique devant la sonde de reniflage. Voir la Figure 3.
6 © ISO 2017 – Tous droits réservés

---------------------- Page: 11 ----------------------
ISO 20486:2017(F)

Légende
1 joint d'étanchéité 4 fuite d'essai avec ouverture de fuite
2 sonde de reniflage 5 corps de l'adaptateur avec joint d'étanchéité
3 entrée d'air 6 ouverture de la sonde de reniflage avec fente
transversale
Figure 3 — Exemple d'adaptateur de raccordement pour des fuites détectées par reniflage
6.3.3 Adaptation de la température
La fuite inconnue et la ou les fuites de référence utilisées dans l’étalonnage par comparaison doivent
être entreposées pendant au moins 12 h dans la même pièce que celle servant aux essais afin d'aboutir à
un équilibre des températures (une pièce à air conditionné est inutile en l’absence de variations rapides
de la température. En raison des fluctuations de température, un système à air conditionné peut même
accroître l'incertitude de mesure). Le pompage des fuites déchargeant dans le vide, raccordées au DF,
doit commencer dès la phase d'adaptation de la température. Après adaptation de la température, afin
d’éviter toutes variations de température pendant le mesurage, il est recommandé de placer au-dessus
des fuites des poches isolantes (en mousse plastique ou autre matériau similaire).
6.4 Mesurage
6.4.1 Réglage
Il est important de s’assurer que la vitesse de pompage effective à l'entrée du détecteur de fuites pour
les fuites détectées sous vide ou le débit de gaz de la sonde de reniflage pour les fuites en surpression ne
varie pas pendant les mesurages.
Si possible, que l’on utilise le détecteur de fuites ou un dispositif auxiliaire, un long temps d'intégration
peut être utilisé pour réduire l'incertitude statistique de la mesure.
Il convient que tous les instruments de mesure soient réglés de sorte qu’ils donnent à peu près les
déviations à pleine échelle pour la fuite la plus importante.
6.4.2 Ordre général des opérations de mesurage
En général, chaque lecture doit être obtenue uniquement après stabilisation du signal de l'instrument
de transfert. Un nombre de lectures suffisant doit être relevé afin de réduire autant que possible
© ISO 2017 – Tous droits réservés 7

---------------------- Page: 12 ----------------------
ISO 20486:2017(F)

l’incertitude statistique. Il est ainsi possible d'obtenir également une mesure des écarts statistiques.
L’ordre général
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.