ISO/DIS 6588-1
(Main)Paper, board and pulps -- Determination of pH of aqueous extracts
Paper, board and pulps -- Determination of pH of aqueous extracts
Papier, carton et pâtes -- Détermination du pH des extraits aqueux
General Information
RELATIONS
Buy Standard
Standards Content (sample)
DRAFT INTERNATIONAL STANDARD ISO/DIS 6588-1
ISO/TC 6 Secretariat: SCC
Voting begins on: Voting terminates on:
2003-04-03 2003-09-03
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
Paper, board and pulps — Determination of pH of aqueousextracts —
Part 1:
Cold extraction
Papier, carton et pâtes — Détermination du pH des extraits aqueux —
Partie 1: Extraction à froid
(Revision of ISO 6588:1981)
ICS 85.040; 85.060
To expedite distribution, this document is circulated as received from the committee secretariat.
ISO Central Secretariat work of editing and text composition will be undertaken at publication
stage.Pour accélérer la distribution, le présent document est distribué tel qu'il est parvenu du
secrétariat du comité. Le travail de rédaction et de composition de texte sera effectué au
Secrétariat central de l'ISO au stade de publication.THIS DOCUMENT IS A DRAFT CIRCULATED FOR COMMENT AND APPROVAL. IT IS THEREFORE SUBJECT TO CHANGE AND MAY NOT BE
REFERRED TO AS AN INTERNATIONAL STANDARD UNTIL PUBLISHED AS SUCH.IN ADDITION TO THEIR EVALUATION AS BEING ACCEPTABLE FOR INDUSTRIAL, TECHNOLOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN NATIONAL REGULATIONS.© International Organization for Standardization, 2003
---------------------- Page: 1 ----------------------
ISO/DIS 6588-1
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
Copyright noticeThis ISO document is a Draft International Standard and is copyright-protected by ISO. Except as permitted
under the applicable laws of the user's country, neither this ISO draft nor any extract from it may be
reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, photocopying,
recording or otherwise, without prior written permission being secured.Requests for permission to reproduce should be addressed to either ISO at the address below or ISO's
member body in the country of the requester.ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Reproduction may be subject to royalty payments or a licensing agreement.
Violators may be prosecuted.
ii ISO 2003 – All rights reserved
---------------------- Page: 2 ----------------------
Contents Page
Foreword............................................................................................................................................................ iv
Introduction ........................................................................................................................................................ v
1 Scope..................................................................................................................................................... 1
2 Normative references ........................................................................................................................... 1
3 Principle................................................................................................................................................. 1
4 Reagents................................................................................................................................................ 2
5 Apparatus and equipment.................................................................................................................... 2
6 Sampling and preparation of sample.................................................................................................. 2
6.1 Sampling................................................................................................................................................ 2
6.2 Preparation of sample .......................................................................................................................... 2
7 Procedure.............................................................................................................................................. 2
7.1 Weighing................................................................................................................................................ 3
7.2 Extraction............................................................................................................................................... 3
7.3 Determination of pH.............................................................................................................................. 3
8 Calculation............................................................................................................................................. 3
9 Precision................................................................................................................................................ 4
9.1 Repeatability.......................................................................................................................................... 4
9.2 Reproducibility...................................................................................................................................... 4
10 Test report............................................................................................................................................. 4
Annex A (informative) Preparation of some standard buffer solutions....................................................... 5
Bibliography ....................................................................................................................................................... 6
---------------------- Page: 3 ----------------------Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards adopted
by the technical committees are circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.
ISO shall not be held responsible for identifying any or all such patent rights.ISO 6588-1 was prepared by Technical Committee ISO/TC 6, Paper, board and pulps.
This first edition of ISO 6588-1 cancels and replaces ISO 6588:1981. The 1981 edition has been technically
revised and split into two parts: 6588-1 for cold extraction and 6588-2 for hot extraction. There are four major
differences compared with the previous edition of ISO 6588:1981:a) the Standard has been divided into two parts; one dealing with cold extraction and the other with hot
extraction;b) the determination is now carried out on an air dry sample without determination of dry matter content, as
the amount of sample is not critical;c) the extract is filtered;
d) a salt solution is added to speed up the measurement.
ISO 6588 consists of the following parts, under the general title Paper, board and pulps — Determination of pH of
aqueous extracts: Part 1: Cold Extraction
Part 2: Hot extraction
The work within ISO/TC 6 has shown that the results obtained with the new Standard are equal to those obtained
by the first edition (ISO 6588:1981).---------------------- Page: 4 ----------------------
Introduction
The kraft fibre is well known to contain ionisable groups that are fixed to or in the fibre wall. In order to fulfil the
electro-neutrality, these groups are balanced by an equivalent number of positive charges, which can be either
protons or various metal ions. Especially in pulp suspensions at low ionic strengths this can give rise to a marked
uneven distribution of mobile ions between the volume held by the fibre wall and the bulk suspension liquor. This
means that the fibre acts as an ion exchanger. These ion exchange phenomena can be modelled very well with the
Donnan theory [1,2].If a relatively clean pulp fibre sample, as for example bleached dried pulp, is diluted in deionised water the result
will be a pulp suspension with a very low ionic strength. In such a system most of the cations present, including
protons, will be concentrated in the water volume held by the fibre wall. If pH is measured, it will be measured in the
bulk suspension liquor. By adding salt to this kind of system the ion exchange phenomena will be decreased and
the concentration of different cations will be the same in the water held by the fibre wall and in the bulk suspension
liquor. Since the process waters always contain a certain amount of ions such a salt addition will give a more
realistic environment when measuring the pH of relatively clean pulp samples.It is necessary to be aware of these effects when interpreting the measured pH-values of highly purified pulps.
---------------------- Page: 5 ------...
PROJET DE NORME INTERNATIONALE ISO/DIS 6588-1
ISO/TC 6 Secrétariat: SCC
Début de vote: Vote clos le:
2003-04-03 2003-09-03
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
Papier, carton et pâtes — Détermination du pH des extraitsaqueux —
Partie 1:
Extraction à froid
Paper, board and pulps — Determination of pH of aqueous extracts —
Part 1: Cold extraction
(Révision de l’ISO 6588:1981)
ICS 85.040; 85.060
Pour accélérer la distribution, le présent document est distribué tel qu'il est parvenu du
secrétariat du comité. Le travail de rédaction et de composition de texte sera effectué au
Secrétariat central de l'ISO au stade de publication.To expedite distribution, this document is circulated as received from the committee secretariat.
ISO Central Secretariat work of editing and text composition will be undertaken at publication
stage.CE DOCUMENT EST UN PROJET DIFFUSÉ POUR OBSERVATIONS ET APPROBATION. IL EST DONC SUSCEPTIBLE DE MODIFICATION ET NE PEUT
ÊTRE CITÉ COMME NORME INTERNATIONALE AVANT SA PUBLICATION EN TANT QUE TELLE.OUTRE LE FAIT D'ÊTRE EXAMINÉS POUR ÉTABLIR S'ILS SONT ACCEPTABLES À DES FINS INDUSTRIELLES, TECHNOLOGIQUES ET
COMMERCIALES, AINSI QUE DU POINT DE VUE DES UTILISATEURS, LES PROJETS DE NORMES INTERNATIONALES DOIVENT PARFOIS ÊTRE
CONSIDÉRÉS DU POINT DE VUE DE LEUR POSSIBILITÉ DE DEVENIR DES NORMES POUVANT SERVIR DE RÉFÉRENCE DANS LA
RÉGLEMENTATION NATIONALE.© Organisation internationale de normalisation, 2003
---------------------- Page: 1 ----------------------
ISO/DIS 6588-1
PDF — Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info du
fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir l'exploitation
de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation, veuillez en informer
le Secrétariat central à l'adresse donnée ci-dessous.Notice de droit d'auteur
Ce document de l'ISO est un projet de Norme internationale qui est protégé par les droits d'auteur de l'ISO.
Sauf autorisé par les lois en matière de droits d'auteur du pays utilisateur, aucune partie de ce projet ISO ne
peut être reproduite, enregistrée dans un système d'extraction ou transmise sous quelque forme que ce soit
et par aucun procédé, électronique ou mécanique, y compris la photocopie, les enregistrements ou autres,
sans autorisation écrite préalable.Les demandes d'autorisation de reproduction doivent être envoyées à l'ISO à l'adresse ci-après ou au comité
membre de l'ISO dans le pays du demandeur.ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Toute reproduction est soumise au paiement de droits ou à un contrat de licence.
Les contrevenants pourront être poursuivis.
ii ISO 2003 – Tous droits réservés
---------------------- Page: 2 ----------------------
Sommaire Page
Avant-propos..................................................................................................................................................... iv
Introduction ........................................................................................................................................................ v
1 Domaine d'application.......................................................................................................................... 1
2 Références normatives ........................................................................................................................ 1
3 Principe.................................................................................................................................................. 1
4 Réactifs.................................................................................................................................................. 2
5 Appareillage et équipement................................................................................................................. 2
6 Échantillonnage et preparation de l'échantillon................................................................................ 2
6.1 Échantillonage....................................................................................................................................... 2
6.2 Préparation de l'échantillon................................................................................................................. 2
7 Mode opératoire .................................................................................................................................... 2
7.1 Pesée...................................................................................................................................................... 3
7.2 Extraction............................................................................................................................................... 3
7.3 Determination du pH............................................................................................................................. 3
8 Calculs ................................................................................................................................................... 3
9 Précision................................................................................................................................................ 4
9.1 Répétabilité............................................................................................................................................ 4
9.2 Reproductibilité..................................................................................................................................... 4
10 Procès-verbal d'essai ........................................................................................................................... 4
Annexe A (informative) Préparation des solutions tampons étalons .......................................................... 5
Bibliographie ...................................................................................................................................................... 6
---------------------- Page: 3 ----------------------Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée aux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l'approbation de 75 % au moins des comités membres votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de droits de
propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne pas avoir
identifié de tels droits de propriété et averti de leur existence.L'ISO 6588-1 a été élaborée par le comité technique ISO/TC 6, Papiers, Cartons et Pâtes.
Cette première édition de l'ISO 6588-1 annule et remplace l'ISO 6588:1981. L'édition de 1981 a été l'objet d'une
révision technique et a été séparée en deux parties: 6588-1 pour l'extraction à froid et 6588-2 pour l'extraction à
chaud. Il y a quatre différences majeures par rapport à l'édition précédente, ISO 6588:1981:
1) La norme a été séparée en deux parties, une pour l'extraction à froid et l'autre à l'extraction à chaud;
2) La détermination est maintenant effectuée sur un échantillon séché à l'air, sans détermination de la teneur
en matière sèche, puisque la quantité de l'échantillon n'est pas critique;3) L'extrait est filtré;
4) une solution saline est ajoutée pour rendre la détermination plus rapide.
L'ISO 6588 comprend les parties suivantes, présentées sous le titre général Papier, carton et pâtes —
Détermination du pH des extraits aqueux: Partie 1: Extraction à froid
Partie 2: Extraction à chaud
Des travaux dans le cadre du Comité technique 6 de l'ISO ont démontré que les résultats obtenus avec cette
nouvelle norme sont égaux à ceux obtenus selon la première édition (ISO 6588:1981).
---------------------- Page: 4 ----------------------Introduction
Il est bien connu que la fibre kraft contient des groupes ionisables qui sont fixés à ou se trouvent à l'intérieur de la
paroi de la fibre. Afin de satisfaire l'électroneutralité, ces groupes sont équilibrés par un nombre égal de charges
positives, qui peuvent être des protons ou des ions métalliques divers. En particulier dans les pâtes de faible
concentration ionique, ceci peut mener à une distribution inégale des ions mobiles entre le volume emprisonné
dans la paroi de la fibre et le reste de la suspension. Ceci signifie que la fibre agit en tant qu'échangeur d'ions. Ce
phénomène d'échange d'ions peut être modélisé très bien en utilisant la théorie de Donnan [1,2].
Si un échantillon de pâte de fibres relativement propre, comme par exemple une pâte blanchie et séchée, est dilué
dans de l'eau déionisée, le résultat sera une pâte en suspension de très faible concentration ionique. Dans un tel
système, la plupart des cations présents, incluant les protons, seront concentrés dans un volume d'eau retenu par
la paroi de la fibre. Si le pH est mesuré, il sera mesuré dans la pâte environnante. En ajoutant un sel à ce type de
système, le phénomène d'échange d'ions sera diminué et la concentration des différents cations sera identique
dans l'eau emprisonnée par la paroi de la fibre et le reste de la pâte en suspension. Puisque les eaux de
procédés contiennent toujours une certaine quantité d'ions, un tel ajout d'un sel résultera en un environnement plus
réaliste lors de la mesure du pH d'échantillons de pâtes relativement propres.Il est nécessaire d'être conscient de ces effets lors de l'interprétation des valeurs de pH telles que mesurées pour
des pâtes hautement purifiées.---------------------- Page: 5 ----------------------
PROJET DE NORME INTERNATIONALE ISO/DIS 6588-1
Papier, carton et pâtes — Détermina
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.