Connectors for electronic equipment - Product requirements -- Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 1 000 MHz

This part of IEC 61076 establishes uniform specifications, type testing requirements and quality assessment procedures for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 1 000 MHz, and intended to be used within cabling for information and communications technology, home entertainment and multimedia. It contains a choice of all test methods and sequences, severity and preferred values for dimensions and characteristics.

Steckverbinder für elektronische Einrichtungen - Produktanforderungen -- Teil 3-104: Bauartspezifikation für geschirmte freie und feste Steckverbinder, 8polig, für Datenübertragungen bis 1000 MHz

Connecteurs pour équipements électroniques - Exigences de produit -- Partie 3-104: Spécification particulière pour connecteurs blindés à 8 voies,socle et fiche, pour transmissions de données, pour fréquences jusqu'à 1000 MHz

La CEI 61076-3-104:2006 Etablit des spécifications uniformes, des exigences d'essais de type et des procédures d'assurance qualité pour les fiches et les embases écrantées pour la transmission de données à des fréquences jusqu'à 1 000 MHz destinées à être utilisées dans les câblages de technologies de l'information et de communication et d'applications de loisirs et multimédia domestiques. Elle donne une sélection de toutes les méthodes et séquences d'essai, de la sévérité applicable et des valeurs préférentielles pour les dimensions et les caractéristiques. Cette deuxième édition de la CEI 61076-3-104 annule et remplace la première édition publiée en 2003 et constitue une révision technique. Les modifications apportées à la première édition de la présente norme (2003) sont d'une part de nature éditoriale sur l'ensemble de la norme et correspondent d'autre part à une augmentation de la fréquence supérieure qui a été portée de 600 MHz à 1000 MHz et à des changements dans l'article caractéristiques (Article 6) et dans l'article programmes d'essai (Article 7) destinés à aligner le document sur les programmes d'essai des documents de la série CEI 60603-7. La présente version bilingue (2013-06) correspond à la version anglaise monolingue publiée en 2006-07.
Mots-clés: 8 voies, fiches écrantées, embases écrantées

Konektorji za elektronsko opremo - Zahteve za izdelek - 3-104. del: Podrobna specifikacija za 8-redne, zaslonjene proste in pritrjene konektorje za prenos podatkov s frekvencami do 1000 MHz (IEC 61076-3-104:2006)

General Information

Status
Withdrawn
Publication Date
04-Dec-2007
Withdrawal Date
08-Oct-2020
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
09-Oct-2020
Due Date
01-Nov-2020
Completion Date
09-Oct-2020

Relations

Buy Standard

Standard
EN 61076-3-104:2008
English language
86 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61076-3-104:2008
01-februar-2008
1DGRPHãþD
SIST EN 61076-3-104:2004
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-104. del: Podrobna
specifikacija za 8-redne, zaslonjene proste in pritrjene konektorje za prenos
podatkov s frekvencami do 1000 MHz (IEC 61076-3-104:2006)
Connectors for electronic equipment - Product requirements - Part 3-104: Detail
specification for 8-way, shielded free and fixed connectors for data transmissions with
frequencies up to 1 000 MHz (IEC 61076-3-104:2006)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-104:
Bauartspezifikation für geschirmte freie und feste Steckverbinder, 8 polig, für
Datenübertragungen bis 1000 MHz (IEC 61076-3-104:2006)
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-104:
Spécification particuliere pour connecteurs blindés a 8 voies,socle et fiche, pour
transmissions de données, pour fréquences jusqu'a 1000 MHz (IEC 61076-3-104:2006)
Ta slovenski standard je istoveten z: EN 61076-3-104:2006
ICS:
31.220.10
SIST EN 61076-3-104:2008 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 61076-3-104

NORME EUROPÉENNE
November 2006
EUROPÄISCHE NORM

ICS 31.220.10 Supersedes EN 61076-3-104:2003


English version


Connectors for electronic equipment -
Product requirements
Part 3-104: Detail specification for 8-way, shielded free
and fixed connectors for data transmissions
with frequencies up to 1 000 MHz
(IEC 61076-3-104:2006)

Connecteurs pour équipements Steckverbinder für elektronische
électroniques - Einrichtungen -
Exigences de produit Produktanforderungen
Partie 3-104: Spécification particulière Teil 3-104: Bauartspezifikation
pour connecteurs blindés a 8 voies , für geschirmte freie und
socle et fiche, pour transmissions feste Steckverbinder, 8polig,
de données, pour fréquences für Datenübertragungen
jusqu'à 1000 MHz bis 1000 MHz
(CEI 61076-3-104:2006) (IEC 61076-3-104:2006)



This European Standard was approved by CENELEC on 2006-10-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61076-3-104:2006 E

---------------------- Page: 2 ----------------------

EN 61076-3-104:2006 - 2 -
Foreword
The text of document 48B/1678/FDIS, future edition 2 of IEC 61076-3-104, prepared by SC 48B,
Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic
equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 61076-3-104 on 2006-10-01.
This European Standard supersedes EN 61076-3-104:2003.
Changes from EN 61076-3-104:2003 include editorial changes throughout the standard and:
– an increase of upper frequency from 600 MHz to 1 000 MHz;
– changes to the characteristics clause (Clause 6) and test schedules clause (Clause 7) to align the
document with test schedules of EN 60603-7 series documents.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-07-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-10-01
The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning connectors given
in 3.2.2 and 3.2.4.
The IEC and CENELEC take no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he is willing to give free licences to applicants
throughout the world. In this respect, the statement of the holder of this patent right is registered with the
IEC.
Information may be obtained from:
The Siemon Company
Siemon Business Park
76 Westbury Park Road
Watertown, CT 06795-0400
USA
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights other than those identified above. IEC and CENELEC shall not be held responsible for
identifying any or all such patent rights.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61076-3-104:2006 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 61076-3-104:2006
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

1)
IEC 60050-581 - International Electrotechnical Vocabulary - -
(IEV)
Chapter 581: Electromechanical components
for electronic equipment


1) 2)
IEC 60068-1 - Environmental testing EN 60068-1 1994
Part 1: General and guidance


1) 2)
IEC 60068-2-6 - Environmental testing EN 60068-2-6 1995
Part 2: Tests - Test Fc: Vibration (sinusoidal)


1)
IEC 60169-16 - Radio-frequency connectors - -
Part 16: R.F. coaxial connectors with inner
diameter of outer conductor 7 mm (0,276 in)
with screw coupling - Characteristic
impedance 50 ohms (75 ohms) (Type N)


IEC 60352 Series Solderless connections EN 60352 Series


IEC 60512 Series Connectors for electronic equipment - EN 60512 Series
Tests and measurements


1) 2)
IEC 60512-1-100 - Connectors for electronic equipment - EN 60512-1-100 2006
Tests and measurements
Part 1-100: General - Applicable publications


1) 2)
IEC 60603-7 - Connectors for frequencies below 3 MHz EN 60603-7 1997
for use with printed boards
Part 7: Detail specification for connectors,
8-way, including fixed and free connectors
with common mating features, with assessed
quality


IEC 61076-1 2006 Connectors for electronic equipment - EN 61076-1 2006
Product requirements
Part 1: Generic specification


1)
IEC 61156-2 - Milticore and symmetrical pair/quad cables - -
for digital communications
Part 2: Horizontal floor wiring - Sectional
specification



1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 4 ----------------------

EN 61076-3-104:2006 - 4 -
Publication Year Title EN/HD Year
1)
IEC 61156-3 - Multicore and symmetrical pair/quad cables - -
for digital communications
Part 3: Work area wiring - Sectional
specification


1)
IEC 61156-4 - Multicore and symmetrical pair/quad cables - -
for digital communications
Part 4: Riser cables - Sectinal specification


1)
IEC 61156-5 - Multicore and symmetrical pair/quad cables - -
for digital communications
Part 5: Symmetrical pair/quad cables with
transmission characteristics up to 600 MHz -
Horizontal floor wiring - Sectional
specification


IEC 61196 Series Coaxial communication cables - -


1)
ISO/IEC 11801 - Information technology - Generic cabling for - -
 customer premises


1)
- - Communication cables - Specifications for EN 50289-1-14 -
test methods
Part 1-14: Electrical test methods - Coupling
attenuation or screening attenuation of
connecting hardware


1) 2)
ISO 1302 - Geometrical Product Specifications (GPS) - EN ISO 1302 2002
Indication of surface texture in technical
product documentation


1)
ITU-T G.117 - Transmission aspects of unbalance about - -
earth


1)
ITU-T O.9 - Measuring arrangements to assess the - -
degree of unbalance about earth

---------------------- Page: 5 ----------------------

INTERNATIONAL IEC


STANDARD 61076-3-104





Second edition
2006-07


Connectors for electronic equipment –
Product requirements –
Part 3-104:
Detail specification for 8-way, shielded free
and fixed connectors for data transmissions
with frequencies up to 1 000 MHz
 IEC 2006  Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale XC
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 6 ----------------------

– 2 – 61076-3-104  IEC:2006(E)
CONTENTS
FOREWORD.5

1 General .7
1.1 Scope.7
1.2 Normative references .7
2 Technical information .8
2.1 Terminology .8
2.2 Groups of related connectors .9
2.3 Interchangeability level.9
2.4 IEC type designation .9
3 Isometric views and common features .10
3.1 General .10
3.2 Isometric views .11
4 Terminations .26
4.1 General .26
4.2 Referenced termination types .26
4.3 Accessories.27
4.4 Mounting information for fixed connectors .27
4.5 Mounting information for free connectors.27
5 Gauges .27
5.1 General .27
5.2 Fixed connector (outlet) gauges .28
5.3 Free connector (plug) gauges.31
5.4 Test panels .35
6 Characteristics .35
6.1 General .35
6.2 Pin and pair grouping assignment .35
6.3 Classification into climatic categories .36
6.4 Electrical characteristics.37
6.5 Transmission characteristics .39
6.6 Mechanical.41
7 Qualification approval test schedule .42
7.1 General .42
7.2 Test procedures and measuring methods .42
7.3 Preconditioning .42
7.4 Wiring and Mounting of Specimens.43
7.5 Contact resistance measurement arrangement procedure .43
7.6 Arrangement for dynamic stress tests (test phase CP1).44
7.7 Test schedules .44
8 Quality assessment procedures.51

Annex A (normative) Gauging requirements .52
Annex B (normative) Locking device mechanical operation.53
Annex C (normative) Plug and outlet interoperability qualification .54

Annex D (normative) General requirements for the measurement set-up .56

---------------------- Page: 7 ----------------------

61076-3-104  IEC:2006(E) – 3 –
Annex E (normative) Insertion loss .61
Annex F (normative) Return loss .63
Annex G (normative) Near end cross talk (NEXT) .65
Annex H (normative) Far end cross talk (FEXT).68
Annex I (normative) Transfer impedance .71
Annex J (normative) Transverse Conversion Loss (TCL) and Transverse Conversion
Transfer Loss (TCTL) .78
Annex K (normative) Termination of balun .81

Figure 1 – Isometric view of cable and PCB fixed connectors.11
Figure 2 – Isometric view of 4, 2 and 1 pair free connectors.11
Figure 3 – Variant 01 drawing 1 .12
Figure 4 – Variant 01 drawing 2 .14
Figure 5 – Variant 02 drawing .15
Figure 6 – Variant 03 drawing 1 .16
Figure 7 – Variant 03 drawing 2 .18
Figure 8 – Variant 03 drawing 3 .19
Figure 9 – Variant 04 drawing 1 .20
Figure 10 – Variant 04 drawing 2 .21
Figure 11 – Variant 05 drawing 1 .22
Figure 12 – Variant 05 drawing 2 .24
Figure 13 – Variant 05 drawing 3 .25
Figure 14 – Fixed connector location "Go" gauge.28
Figure 15 – Fixed connector location "No-Go" gauge .28
Figure 16 – Fixed connector size "Go" gauge.29
Figure 17 – Fixed connector size "No-Go" gauge .30
Figure 18 – Free connector location "Go" gauge .31
Figure 19 – Free connector location "No-Go" gauge .31
Figure 20 – Free connector size "Go" gauge .32
Figure 21 – Free connector size "No-Go" gauge .33
Figure 22 – Fixed connector panel .35
Figure 23 – Isometric views fixed connector.36
Figure 24 – Isometric views free connector 4 pair .36
Figure 25 – Connector de-rating curve .38
Figure 26 – Arrangement for contact resiestance test .43
Figure 27 – Arrangement for dynamic stress .44
Figure C.1 – Precision test fixtures (covers).54
Figure D.1 – 180° hybrid used as a balun .57
Figure D.2 – Calibration of reference loads.58
Figure D.3 – Resistor load .59
Figure D.4 – Definition of reference planes .60
Figure E.1 – Calibration .61
Figure E.2 – Measuring set-up .62

---------------------- Page: 8 ----------------------

– 4 – 61076-3-104  IEC:2006(E)
Figure G.1 – NEXT measurement differential mode only terminations .65
Figure G.2 – NEXT measurement differential and common mode terminations.66
Figure H.1 – FEXT measurement differential mode only terminations.68
Figure H.2 – FEXT measurement differential and common mode terminations .69
Figure I.1 – Preparation of test specimen.72
Figure I.2 – Triaxial test set-up .73
Figure I.3 – Impedance matching for R < 50 Ω .74
1
Figure I.4 – Impedance matching for R > 50 Ω .75
1
Figure J.1 – TCL measurement.78
Figure J.2 – TCTL measurement.79
Figure K.1 – Balanced attenuator for balun centre tap grounded.81
Figure K.2 – Balanced attenuator for balun centre tap open.81

Table 1 – Variant 01 drawing 1 dimensions.13
Table 2 – Variant 01 drawing 2 dimensions.14
Table 3 – Variant 02 drawing dimensions.15
Table 4 – Variant 03 drawing 1 dimensions.17
Table 5 – Variant 03 drawing 2 dimensions.18
Table 6 – Variant 03 drawing 3 dimensions.19
Table 7 – Variant 04 drawing 1 dimensions.21
Table 8 – Variant 04 drawing 2 dimensions.22
Table 9 – Variant 05 drawing 1 dimensions.23
Table 10 – Variant 05 drawing 2 dimensions .24
Table 11 – Variant 05 drawing 3 dimensions .25
Table 12 – Fixed connector (outlet) gauge dimensions.30
Table 13 – Free connector (plug) gauge dimensions .34
Table 14 – Fixed connector panel dimensions.35
Table 15 – Climatic categories – selected values.37
Table 16 – Creepage and clearance distances.37
Table 17 – Test group P .45
Table 18 – Test group AP .46
Table 19 – Test group BP .48
Table 20 – Test group CP .49
Table 21 – Test group DP .49
Table 22 – Test Group EP .50
Table 23 – Test Group FP.51
Table D.1 – Test balun performance characteristics.57
Table F.1 – Uncertainty band of return loss measurement at frequencies below
100 MHz .64

---------------------- Page: 9 ----------------------

61076-3-104  IEC:2006(E) – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________

CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –

Part 3-104: Detail specification for 8-way, shielded free and fixed
connectors for data transmissions with frequencies up to 1 000 MHz


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance
with this document may involve the use of a patent concerning connectors given in 3.2.2 and 3.2.4.
The IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he is willing to give free licences with applicants throughout
the world. In this respect, the statement of the holder of this patent right is registered with the IEC
Information may be obtained from:
The Siemon Company
Siemon Business Park
76 Westbury Park Road
Watertown, CT 06795-0400
USA
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights other than those identified above. IEC shall not be held responsible for identifying any or all such
patent rights.
International Standard IEC 61076-3-104 has been prepared by sub-committee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.

---------------------- Page: 10 ----------------------

– 6 – 61076-3-104  IEC:2006(E)
This second edition of IEC 610
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.