SIST EN 50132-4-1:2001
(Main)Alarm systems - CCTV surveillance systems for use in security applications -- Part 4-1: Black and white monitors
Alarm systems - CCTV surveillance systems for use in security applications -- Part 4-1: Black and white monitors
D127/C151: Withdrawal votes - Standstill to be released
Alarmanlagen - CCTV-Überwachungsanlagen für Sicherungsanwendungen -- Teil 4-1: Schwarzweiß-Monitore
Systèmes d'alarme - Systèmes de surveillance CCTV à usage dans les applications de sécurité -- Partie 4-1: Moniteurs noir et blanc
Alarm systems - CCTV surveillance systems for use in security applications - Part 4-1: Black and white monitors
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50132-4-1:2001
01-november-2001
Alarm systems - CCTV surveillance systems for use in security applications - Part
4-1: Black and white monitors
Alarm systems - CCTV surveillance systems for use in security applications -- Part 4-1:
Black and white monitors
Alarmanlagen - CCTV-Überwachungsanlagen für Sicherungsanwendungen -- Teil 4-1:
Schwarzweiß-Monitore
Systèmes d'alarme - Systèmes de surveillance CCTV à usage dans les applications de
sécurité -- Partie 4-1: Moniteurs noir et blanc
Ta slovenski standard je istoveten z: EN 50132-4-1:2001
ICS:
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
33.160.40 Video sistemi Video systems
SIST EN 50132-4-1:2001 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50132-4-1:2001
---------------------- Page: 2 ----------------------
SIST EN 50132-4-1:2001
EUROPEAN STANDARD EN 50132-4-1
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2001
ICS 13.310
English version
Alarm systems -
CCTV surveillance systems for use in security applications
Part 4-1: Black and white monitors
Systèmes d'alarme - Alarmanlagen -
Systèmes de surveillance CCTV à usage CCTV-Überwachungsanlagen für
dans les applications de sécurité Sicherungsanwendungen
Partie 4-1: Moniteurs noir et blanc Teil 4-1: Schwarzweiß-Monitore
This European Standard was approved by CENELEC on 1999-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any
other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50132-4-1:2001 E
---------------------- Page: 3 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 2 -
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 79, Alarm
systems.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50132-4-1 on 1999-10-01.
The following dates were fixed:
- latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-02-01
- latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2002-10-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annex A is normative.
EN 50132 will consist of the following parts, under the general title “Alarm systems – CCTV
surveillance systems for use in security applications”:
- Part 1 System requirements;
- Part 2-1 Black and white cameras;
- Part 2-2 Colour cameras;
- Part 2-3 Lenses;
- Part 2-4 Ancillary equipment;
- Part 3 Local and main control unit;
- Part 4-1 Black and white monitors;
- Part 4-2 Colour monitors;
- Part 4-3 Recording equipment;
- Part 4-4 Hard copy equipment;
- Part 4-5 Video motion detection equipment;
- Part 5 Video transmission;
- Part 6 (free);
- Part 7 Application guidelines.
---------------------- Page: 4 ----------------------
SIST EN 50132-4-1:2001
- 3 - EN 50132-4-1:2001
Contents
page
Introduction .5
1 Scope .5
2 Normative references.5
3 Definitions and abbreviations.6
3.1 Definitions .6
3.2 Abbreviations .8
4 Requirements .9
4.1 General .9
4.2 Scanning standard and synchronization.9
4.3 Visible diagonal of the display device .9
4.4 Input impedance.9
4.5 Input signal level and polarity.9
4.6 Interlace factor .9
4.7 Frequency response.9
4.8 Horizontal resolution.9
4.9 Modulation transfer function .9
4.10 Geometric distortion .10
4.11 Picture size stability.10
4.12 Black level stability.10
4.13 Grey scale .10
4.14 Interference and positional hum.10
4.15 Power supply.10
4.16 Electrical safety.10
4.17 X-ray radiation.10
4.18 Electro-magnetic compatibility (emission) .10
4.19 Electro-magnetic compatibility (immunity) .10
4.20 Environmental conditions .11
5 Test conditions .11
5.1 General .11
5.2 Test equipment .11
5.3 Test conditions.12
6 Performance tests.13
6.1 Input signal level test.13
6.2 Polarity of the input signal test .14
6.3 Video input termination .14
6.4 Synchronization.16
6.5 Picture size stability.16
---------------------- Page: 5 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 4 -
6.6 Black level stability.18
6.7 Grey scale .18
6.8 Frequency response.19
6.9 Interlace factor .22
6.10 Geometric distortion .23
6.11 Horizontal resolution.24
6.12 Modulation transfer function .25
6.13 Positional hum .26
6.14 Mutual interference.26
7 Environmental testing .27
7.1 Introduction.27
7.2 Selection of tests and severities .28
7.3 Dry heat (operational) .28
7.4 Dry heat (endurance) .30
7.5 Cold (operational).31
7.6 Damp heat, steady state (operational .32
7.7 Damp heat, steady state (endurance) .33
7.8 Damp heat, cyclic (operational) .34
7.9 Damp heat, cyclic (endurance) .35
7.10 Water (endurance).36
7.11 Sulphur dioxide (SO ) corrosion (endurance) .37
2
7.12 Salt mist, cyclic (endurance) .39
7.13 Shock (operational) .40
7.14 Vibration, sinusoidal (operational).41
7.15 Vibration, sinusoidal (endurance).42
7.16 Dust tightness (endurance).43
8 Documentation .44
9 Marking and labelling .45
Annex A Test patterns (normative) .46
A.1 Window signal .46
A.2 Cross hatch signal .47
A.3 Linearity test pattern.48
A.4 Grey scale signal.49
A.5 Frequency burst signal.50
A.6 Checker board signal .50
---------------------- Page: 6 ----------------------
SIST EN 50132-4-1:2001
- 5 - EN 50132-4-1:2001
Introduction
Video monitors are electronic devices able to transform signals generated by television
cameras into visible images corresponding to those focused on the imaging device of a
television camera or electronically generated signals.
A video monitor comprises the following main components:
a) Display device, e.g. cathode ray tube, liquid crystal display, etc.;
b) Video amplification circuits;
c) Synchronization circuits;
d) Power supply circuits;
e) Control and interfacing circuits.
Reference should be made to the guidelines on the application of video monitors in CCTV
systems.
1 Scope
This standard specifies the minimum requirements for the specification and testing of black
and white video monitors used in 625-line CCIR standard closed circuit television (CCTV)
surveillance systems for security applications.
2 Normative references
This European standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and
the publications are listed hereafter. For dated references, subsequent amendments to or
revisions of any of these publications apply to this European Standard only when
incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies.
CCIR report 624-4 Characteristics of television systems
EN 50081-1 1992 Electromagnetic compatibility – Generic emission standard –
Part 1: Residential, commercial and light industry
EN 50130-4 1995 Alarm systems - Part 4: Electromagnetic compatibility -
+ A1 1998 Product family standard: Immunity for components of fire,
intruder and social alarm systems
EN 50132-7 1996 Alarm systems - CCTV surveillance systems for use in security
applications – Part 7: Application guidelines
EN 60065 1998 Audio, video and similar electronic apparatus - Safety
requirements (IEC 60065:1998, mod.)
EN 60068-1 1994 Environmental testing - Part 1: General and guidance
(IEC 60068-1:1988 + corr. Oct.1988 + A1:1992)
EN 60068-2-1 1993 Environmental testing - Part 2: Tests - Tests A: Cold
(IEC 60068-2-1:1990)
+ A1 1993 (IEC 60068-2-1:1990/A1:1993)
+ A2 1994 (IEC 60068-2-1:1990/A2:1994)
---------------------- Page: 7 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 6 -
EN 60068-2-2 1993 Environmental testing - Part 2: Tests - Tests B: Dry heat
(IEC 60068-2-2:1974 + 2A:1976)
+ A1 1993 (IEC 60068-2-2:1974/A1:1993)
+ A2 1994 (IEC 60068-2-2:1974/A2:1994)
EN 60068-2-6 1995 Environmental testing - Part 2: Tests - Test Fc: Vibration
(sinusoidal) (IEC 60068-2-6:1995 + corr. March 1995)
EN 60068-2-18 2001 Environmental testing - Part 2: Tests -Test R and guidance:
Water (IEC 60068-2-18:2000)
EN 60068-2-27 1993 Environmental testing - Part 2: Tests - Test Ea and guidance:
Shock (IEC 60068-2-27:1987)
EN 60068-2-30 1999 Test Db and guidance: Damp heat, cyclic (12 + 12 hour cycle)
(IEC 60068-2-30:1980 + A1:1985)
EN 60068-2-52 1996 Environmental testing - Part 2: Tests - Test Kb : Salt mist,
cyclic (sodium chloride solution) (IEC 60068-2-52:1996)
EN 60529 1991 Degrees of protection provided by enclosures (IP code)
(IEC 60529:1989)
EN 60950 2000 Safety of information technology equipment
(IEC 60950:1999 + corr. 2000, mod.)
HD 323.2.3 S2 1987 Environmental testing - Part 2: Tests - Test Ca: Damp heat
steady state (IEC 60068-2-3:1969 + A1:1984)
IEC 60068-2-42 1982 Test Kc : Sulphur dioxide test for contacts and connections
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this standard, the following definitions and abbreviations apply.
3.1.1
average picture level
average signal level during active scanning time, excluding blanking and synchronization
signals, integrated over one frame period. It is expressed as a percentage of the blanking
(0 V) to reference white (0,7 V) range
3.1.2
aspect ratio
ratio of the frame width to the frame height. The frame is the total area occupied by the
picture which is scanned while the picture is not blanked
3.1.3
black level stability
ability of a monitor to display a stable black level for scenes of varying levels of video
content
3.1.4
composite video signal (CVS)
video output signal of a black and white (b/w) camera comprising the picture component
(video), black reference (blanking) and the synchronization components (synchronization)
[EN 50132-7]
---------------------- Page: 8 ----------------------
SIST EN 50132-4-1:2001
- 7 - EN 50132-4-1:2001
3.1.5
control and interfacing circuits
circuits in a CCTV monitor enabling the connection of the input video signal and enabling
the control of e.g. contrast and brightness of the displayed picture
3.1.6
contrast ratio
ratio of maximum luminance level of a white area in the picture to the luminance level of a
subjective black
3.1.7
dc-restoration
provision in a monitor to restore the dc-component of the video signal
3.1.8
geometric distortion
aberration that causes the reproduced picture to be geometrically dissimilar to the original
scene
3.1.9
grey scale
dynamic range of luminance intensity available from the display device
3.1.10
horizontal resolution
measure of the ability of the monitor to resolve picture detail in the line direction
3.1.11
interlace
positioning of the scan lines of alternate fields so that the even field lines are vertically
spaced between the odd field lines
3.1.12
low frequency response
ability of a monitor to display large areas of uniform luminance accurately in the field
direction
3.1.13
mid frequency response
ability of a monitor to display large areas of uniform luminance accurately in the line
direction
3.1.14
modulation transfer function
contrast at which a high frequency burst can be reproduced on the monitor screen
3.1.15
monitor size
diagonal of the physical tube size, e.g. a 23 cm (9-inch), a 31 cm (12-inch) monitor
3.1.16
mutual interference
phenomenon, sometimes visible on the monitor screen, when two or more monitors
operating on different non synchronised signals are stacked or placed side by side
---------------------- Page: 9 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 8 -
3.1.17
picture zones
three zones on the picture tube used to evaluate picture performance:
Zone I is the central picture area defined by a circle equal to 80 % of the picture height.
Zone II is the area defined by a circle equal to the picture width.
Zone III is the area outside zone II.
Refer to Figure 1.
III III
Zone I
II II
III III
Figure 1
3.1.18
return loss
reflection damping of the monitor input termination
3.1.19
terminated input
input with a termination of 75 Ω
3.1.20
transient response
ability of the monitor to display a step function luminance transition occurring during a
horizontal scan line
3.1.21
unterminated input
input with high impedance, allowing more devices to be connected in parallel
3.1.22
visible display diagonal
visible picture diagonal of the display device
3.2 Abbreviations
3.2.1 APL: Average picture level
3.2.2 CCIR: Comité Consultatif International des Radiocommunications (International
radio consultative committee).
3.2.3 CCTV: Closed circuit television.
---------------------- Page: 10 ----------------------
SIST EN 50132-4-1:2001
- 9 - EN 50132-4-1:2001
4 Requirements
4.1 General
The properties of the monitor shall be provided in a specification sheet covering at least the
parameters listed in subclauses 4.2 to 4.20.
The specifications stated by the manufacturer shall be those determined under the standard
operating conditions.
The monitor shall meet all performance specifications over the specified temperature range
using only the external operator controls adjustment.
The minimum requirements and specification parameters are given in 4.2 to 4.20.
4.2 Scanning standard and synchronization
The scanning standard shall be in accordance with CCIR report 624-4.
The nominal horizontal frequency is 15,625 Hz and the nominal vertical frequency is 50 Hz,
the capture range and holding range shall allow for at least (0 ± 2) % frequency deviation.
4.3 Visible diagonal of the display device
The visible picture diagonal of the display device shall be specified in centimetres.
4.4 Input impedance
The nominal input impedance shall be 75 Ω per termination or ≥ 5 kΩ when the signal is
unterminated. The return loss shall be ≥ 20 dB in the frequency range of 0,1 MHz to 5 MHz.
4.5 Input signal level and polarity
The monitor shall operate to full specification with a composite video signal at the input of
1 V ± 50 % terminated in 75 Ω. The video white part shall be positive going, the
pp
synchronization negative going. The maximum superimposed dc-voltage on the terminated
input shall be (0 ± 2) V.
4.6 Interlace factor
The degree of interlace of the two fields shall be > 0,8.
4.7 Frequency response
Low frequency (frame tilt), mid frequency (line tilt) and transient response shall be
specified.
4.8 Horizontal resolution
The limiting resolution in zone I of the picture shall be specified at (60 ± 5) cd/m² and
(120 ± 10) cd/m² screen luminance. The resolution shall be specified in the number of TV
lines per picture height.
4.9 Modulation transfer function
The modulation transfer function for (400 ± 20) TV lines resolution in zone I of the picture
shall be specified at (60 ± 5) cd/m² screen luminance.
---------------------- Page: 11 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 10 -
4.10 Geometric distortion
The geometric distortion in the centre (zone I) of the picture shall be ≤ 2 % of the picture
height.
4.11 Picture size stability
The percentage of variation of the full image size when switching from low to high
brightness shall be specified.
4.12 Black level stability
The stability of the luminance of the black level shall be specified for the condition when
the picture is switched between the display of a small white area to the display of a 50 %
white area at 120 cd/m².
4.13 Grey scale
The minimum grey scale definition shall be 10 levels, including black and white, at a screen
luminance of 120 cd/m² of the white part of the grey scale.
4.14 Interference and positional hum
The manufacturer shall state whether or not two or more monitors can be used
asynchronously adjacent without visible mutual interference.
The positional hum in the displayed picture shall be less than 0,2 %.
4.15 Power supply
The power supply input voltage range and rated power consumption shall be specified.
4.16 Electrical safety
The monitor shall comply with the EN 60065 or EN 60950 safety requirements.
4.17 X-ray radiation
The X-ray radiation level of the monitor shall be in accordance with the requirements of
EN 60950:2000, subclause 4.3.13.
4.18 Electro-magnetic compatibility (emission)
The radiated interference of the apparatus shall comply with the EN 50081-1 generic EMC
emission standard.
4.19 Electro-magnetic compatibility (immunity)
The interference immunity of the apparatus shall comply with the EN 50130-4 EMC
immunity standard for security equipment.
---------------------- Page: 12 ----------------------
SIST EN 50132-4-1:2001
- 11 - EN 50132-4-1:2001
4.20 Environmental conditions
The apparatus shall withstand the environmental influences of the specified service
environment.
The service environment is defined by selection of one of the four environmental classes:
Class I: Indoor but restricted to residential/office environment.
Class II: Indoor in general.
Class III: Outdoor but sheltered from direct rain and sunshine, or indoor with extreme
environmental conditions.
Class IV: Outdoor in general.
As a minimum, the monitor shall withstand exposure to the environmental influences of the
tests defined in clause 7 for the specified service environment.
Monitors of environmental class II or higher may be mounted in environmental housings to
enable their application in environmental classes III or IV. The environmental housing shall
then conform to the additional requirements for the related environmental class, while
maintaining the specified environmental conditions for the monitor mounted in the housing.
5 Test conditions
5.1 General
The test requirements are designed to determine the performance level of black and white
CCTV monitors. The main operating parameters are described.
Monitors shall also conform to the current safety standards for electronic devices.
If a method of measurement and a standard exists for a given parameter, this has been
used in the following tests.
If a method of measurement and standard does not exist for a given parameter, the method
and standard indicated in this standard takes into account the objectivity, repeatability, and
complexity of the tests.
5.2 Test equipment
Test equipment shall be calibrated to tolerances in relation to the required accuracy of the
respective measurements.
The test equipment normally required is:
a) Video wave form monitor or oscilloscope, preferably with facilities for triggering of
the sweep from the field or line pulses of the video signal. Its input impedance
shall be at least 1 MΩ. For some measurements it is essential that the oscilloscope
has an adjustable delay relative to the field synchronization for the selection of
individual TV lines. A marker pulse output indicating the selected line on a monitor
is useful for measurements on individual TV lines.
b) Luminance meter, indicating cd/m².
c) Test signal generator capable of generating the test signals specified in 5.3.1.
---------------------- Page: 13 ----------------------
SIST EN 50132-4-1:2001
EN 50132-4-1:2001 - 12 -
5.3 Test conditions
5.3.1 Nominal input signal
Unless otherwise specified, all measurements shall be made with a composite video signal,
.
having a nominal level of (1 ± 0,15) V
pp
The synchronizing signal shall be negative going and have a nominal amplitude of
(0,3 ± 0,05) V . The picture signal shall be positive going. The amplitude of the picture
pp
signal with set-up, as measured from blanking level to reference white level, shall have a
nominal amplitude of (0.7 ± 0.1) V . The black level set-up shall be between 0 mV and
pp pp
35 mV . The synchronization component shall be in accordance with CCIR report 624-4.
pp
When the input signal level is varied in a test, the ratio between video and synchronization
signal in the composite video signal shall be maintained.
The input signal shall be supplied to the monitor by means of a 75 Ω coaxial cable
terminated at the monitor in 75 Ω ± 1 %.
The source impedance of the equipment used to transmit the test signal shall also be
75 Ω ± 1 %.
5.3.2 Test signals
Initially the monitor shall be set up using an electronically generated test picture signal.
This signal may be a white window or grey scale with white reference.
The APL of the signal shall be 60 % or less and the composite video signal shall have the
standard level as specified in 5.3.1.
The test signals used in this standard are:
a) Window signal: The window signal to be used in specific tests within this standard
shall generate a displayed rectangle having a 4/3 aspect ratio and an area equal
to nominally 20 % of the normal active raster area (see Figure A.1). This signal
may be generated electronically or by a TV-camera.
b) Cross hatch signal, see Figure A.2.
c) Linearity test pattern, see Figure A.3.
d) Grey scale signal, see Figure A.4.
e) Frequency burst signal, see Figure A.5.
f) Checker board signal, see Figure A.6.
5.3.3 Test preparations
If provisions are available to switch the monitor for NORMAL SCAN/UNDERSCAN
operation, the monitor shall be operated in the NORMAL SCAN mode.
If the monitor includes a switch for DC restoration ON/OFF, it shall be operated in the ON
mode.
The aspect ratio of the displayed area shall be 4/3.
By means of the brightness and contrast controls, the black reference in the video signal
shall be set to subjective black, and the white reference in the video signal set to the
manufacturer’s rated maximum luminance.
To allow for variations in black level, subjective black may be re-established by adjusting
the brightness control only when switching to test signals of different APLs, unless specified
otherwise.
---------------------- Page: 14 ----------------------
SIST EN 50132-4-1:2001
- 13 - EN 50132-4-1:2001
Certain tests such as interlace, luminance stability, low and mid-frequency response, grey
scale and contrast ratio, horizontal resolution, etc. are performed by means of a luminance
meter or a TV camera focused on the monitor face plate. For these tests the ambient light
falling on the display shall be ≤ 3 lux.
Some measurements require that white areas be displayed at approximately 50 % of the
rated maximum luminance of the monitor; in these cases, the composite input video signal
shall have a standard sync level of 0,3 V . The portion of the composite video input signal,
pp
as measured between blanking level and white level, shall be adjusted to have a value of
0,5 V ± 5 %. Because of the non-linear transfer characteristic of the display, the value of
pp
0,5 V shall be used instead of 0,35 V .
pp pp
Certain tests require the use of a calibrated luminance meter; this meter shall have a
defined acceptance angle such that it measures only the specified
...
Questions, Comments and Discussion