This European Standard specifies the requirements for Intrusion and Hold-up Alarm Systems installed in buildings using
specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to the
components of an I&HAS installed in a building which are normally mounted on the external structure of a building e.g.
ancillary control equipment or warning devices. The standard does not include requirements for exterior I&HAS.
This standard specifies perform...
view more

    • sale 10% off
    • Amendment
      11 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for pyrotechnic obscuration security devices as a part of an I&HAS. It covers application and performance and also specifies the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard is not intended to cover standalone or vehicular security pyrotechnic obscuration security device.
This European Standard also gives guidelines on the criteria for design, installation, operation and maintenance ...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system. The components comply either with the requirements of EN 54 or with a manufacturer’s specification where there is no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment.
This document covers transmission path onl...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the minimum requirements for monitoring, receiving and processing of alarm messages generated by alarm systems taking place as an integrated part of the total fire safety and security solution.
For the purpose of this standard, the term “alarm” is used in the broad sense to include fault, status and other messages received from one or more of a range of safety and security alarm systems such as but not limited to fire detection and fire alarm systems, fixed fire...
view more

    • sale 10% off
    • Standard
      44 pages
      English language
    • e-Library read for
      1 day

This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations as specified in EN 50130-5.
This European Standard does not deal with requirements for compliance with EC regulatory Dire...
view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements for Security Fog Devices connected to an I&HAS. It covers application and performance and also gives the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard also gives guidance on the criteria for design, installation, operation and maintenance of Security Fog Devices.
A Security Fog Device is not considered to be a component of an I&HAS and no requirements are given relating to th...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European Standard is not intended to cover:
a)   lou...
view more

    • sale 10% off
    • Standard
      67 pages
      English language
    • e-Library read for
      1 day

This standard specifies the requirements for the performance, reliability and security characteristics of alarm transmission systems.
It covers the general requirements for connections providing signalling between an alarm system at a supervised premises and annunciation equipment at an alarm receiving centre.
EN 50136-1 Applies to transmission systems for all types of alarm messages such as fire, intrusion, access control, social alarm, etc. Different types of alarm system may in addition to ...
view more

    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day

This draft European Standard specifies requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011).
This European standard provides for the assessment of verification of consistency of performance (AVCP) of point smoke detectors to this EN.
For other types of smoke detector, or smoke detectors worki...
view more

    • sale 10% off
    • Standard
      79 pages
      English language
    • e-Library read for
      1 day

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Lock state contacts are installed in windows or doors and windows or doorframes to allow to monitor the lock/unlock status only or the lock/unlock status combined with the open/close status of a window/door simul...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011).
This European Standard provides for the assessment of verification of constancy of performance (AVCP) of point heat detectors to this EN.
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guida...
view more

    • sale 10% off
    • Standard
      62 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE.
This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant prod...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive infrared detectors intended for use outdoors.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this st...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

This draft European Standard specifies the requirements for manually and automatically activated trigger devices transmitting a triggering signal.
This draft European Standard specifies the requirements and tests for trigger devices forming part of a social alarm system.
This draft European Standard applies to all trigger devices that transmit a triggering signal to a local unit or controller using wired or wire-free interconnections methods.

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

These application guidelines include guidance on the application of the design, planning, operation, installation, commissioning and maintenance of alarm transmission systems for use in fire, I&HAS, Social Alarms and VSS applications. This document does NOT specify requirements. The requirements for ATS and ATE are specified in other parts of the EN 50136 series of standards.
These application guidelines are intended to assist those responsible for establishing an ATS(n) to ascertain the approp...
view more

    • sale 10% off
    • Technical specification
      22 pages
      English language
    • e-Library read for
      1 day

This Technical Specification specifies a protocol for point-to-point transmission of alarms and faults, as well as communications monitoring, between a Supervised Premises Transceiver and a Receiving Centre Transceiver using the Internet protocol (IP).
The protocol is intended for use over any network that supports the transmission of IP data. These include Ethernet, xDSL, GPRS, WiFi, UMTS and WIMAX.
The system performance characteristics for alarm transmission are specified in EN 50136-1 and ...
view more

    • sale 10% off
    • Technical specification
      55 pages
      English language
    • e-Library read for
      1 day

Harmonise system requirements with requirements for system components specified in standard published since EN 50131-1:2006 was published.

    • sale 10% off
    • Amendment
      14 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to intrusion alarm equipment using radio frequency (RF) links and located on protected premises. It does not cover long-range radio transmissions.
This European Standard defines the terms used in the field of intrusion alarm equipment using radio frequency links as well as the requirements relevant to the equipment.

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

This standard applies to the delivery of social alarms services by organisations, whether through the use of paid or voluntary staff. It does not apply to the use of social alarm systems to enhance informal arrangements between an individual and their close friends and family for the provision of assistance, although it may provide advice on the issues that such individuals may need to consider.
This standard specifies requirements for social alarm service providers for effective and efficient ...
view more

    • sale 10% off
    • Standard
      15 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for ALDDR inside buildings and provides four security grades 1 to 4 (see EN 50131-1), specific or non-specific wire or wire-free ALDDR, and uses environmental classes I to IV (see EN 50130-5).
An ALDDR fulfils all the requirements of the specified grade.
The ALDDR detects an intruder inside a predefined area.
This standard covers ALDDR using both pulsed and continuous wave laser operation technologies according to LIDAR principle (Light Detection And Ranging). ...
view more

    • sale 10% off
    • Technical specification
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This European Standard does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks fr...
view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This Technical Specification provides recommendations for those methods of setting and unsetting an Intrusion Alarm System (IAS) complying with EN 50131-1 that will reduce unwanted alarms arising from “operator error” in setting and unsetting the IAS and provide confidence that the conditions in which the system is installed are conducive to system reliability during the “set” period.
This document details optional methods by which these goals may be achieved, either in isolation, or in conjunc...
view more

    • sale 10% off
    • Technical specification
      17 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is applicable to Active Infrared Beam Detectors (AIBDs) installed inside buildings and used as part of intrusion alarm systems.
It specifies four security Grades 1 to 4 (in accordance with EN 50131 1) and uses environmental Classes I to IV (in accordance with EN 50130 5).
This standard covers only AIBDs using interruption based technology. Other technologies i.e. Doppler based technology are not covered by this document.
Functions additional to the mandatory funct...
view more

    • sale 10% off
    • Technical specification
      36 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this ...view more

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes...view more

    • sale 10% off
    • Standard
      107 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54 1:2011).
The non-resettable sensing element has a fixed temperature alarm threshold and does ...
view more

    • sale 10% off
    • Standard
      66 pages
      English language
    • e-Library read for
      1 day

CLC/TC origins due to change in law.

    • sale 10% off
    • Corrigendum
      1 page
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point detectors using carbon monoxide sensing for use in fire detection and fire alarm systems in and around buildings (see EN 54 1:2011).
This European Standard provides for the assessment and verification of consistency of performance (AVCP) of carbon monoxide point detectors to this EN.
This European Standard does not cover fire detectors incorporating at least one CO sensing element in combination with...
view more

    • sale 10% off
    • Standard
      79 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena.
This European Standard provides for the assessment and verification ...
view more

    • sale 10% off
    • Standard
      96 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one carbon monoxide sensor and at least one heat sensor and where the overall fire detection performance is determined utilizing the combination of the detected phenomena.
This European Standard provides for the assessment and verif...
view more

    • sale 10% off
    • Standard
      97 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements, test methods and performance criteria for fire detectors which detect smoke in air ducts in buildings as a part of a fire detection and fire alarm system or as an actuator for a fire protection system. For the testing of other types of smoke detectors, or smoke detectors working on different principles, this document can be used only for guidance. Duct smoke detectors with special characteristics and developed for specific risks are not covered by this docum...view more

    • sale 10% off
    • Standard
      81 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetrat...
view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

CLC/TS 50131-9 is available for use where alarm verification methods are considered necessary. It provides recommendations for the addition and use of alarm verification technology in Intrusion and Hold-up Alarm Systems (I&HAS) installed to comply with EN 50131-1. These recommendations should be incorporated into the respective standards in the EN 5013x series. This Technical Specification does not detail methods of alarm verification relying solely on Alarm Receiving Centre (ARC) procedures, bu...view more

    • sale 10% off
    • Technical specification
      28 pages
      English language
    • e-Library read for
      1 day

EN 50131-10 specifies requirements for SPT used in I&HAS to transmit alarm and other messages to a location remote from the supervised premises. This European Standard gives specific requirements for SPT used in Intrusion and Hold-up Alarm Systems (I&HAS) and should be used in combination with EN 50136-2. The requirements of this European Standard apply to different types of SPT including separate SPT, SPT located within the housings of other I&HAS components and also when the SPT functionality ...view more

    • sale 10% off
    • Standard
      19 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems.

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for d...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this st...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this ...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for microwave detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for combined passive infrared and ultrasonic detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for combined passive infra red and ultrasonic detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the ma...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do n...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This standard is for combined passive infrared and microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be ...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

CLC/TS 50131-2-10 provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. The purpose of a lock state contact (magnetic) is to detect the lock/unlock state only or the lock/unlock state combined with the opening status/displacement from the defined closed position of a window or door simulta...view more

    • sale 10% off
    • Technical specification
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this st...view more

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this ...view more

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day