2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Dentistry - Dental rotary instruments - Test methodsZahnheilkunde - Zahnärztliche rotierende Instrumente - PrüfverfahrenArt dentaire - Instruments rotatifs dentaires - Méthodes d'essaiDentistry - Den
...
This May Also Interest You
This document specifies general test methods for rotary instruments used in dentistry. These test methods are used for measuring the dimensional characteristics, neck strength and surface roughness of rotary instruments, such as burs, cutters, polishers, grinding instruments and rotary instruments used for oral surgery such as drills and countersinks.
Specific tests are specified in the respective instrument standards, if available.
This document does not specify test methods for materials used for rotary instruments.
NOTE For materials used for rotary instruments, see ISO 21850-1 and respective instrument standards.
This document is not applicable to endodontic instruments. For endodontic instruments, see ISO 3630-1.
- Standard19 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements for enlargers not cited in ISO 3630-1, ISO 3630-3, ISO 3630-4, ISO 3630-5, ISO TR 3630-6 or ISO 3630-7.
This document specifies the requirements for size, marking, product designation, safety considerations, and labelling and packaging, including the instructions for use.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft19 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and test methods for stationary dental units concerning
a) the properties of stationary dental unit connections to the compressed air supply, water supply,
suction supply, and wastewater drain plumbing,
b) the materials, design, and construction of the compressed air and water system within the
stationary dental unit,
c) the quality for incoming water and air,
d) the performance of stationary dental unit suction system, and
e) the air, water, suction and wastewater properties of stationary dental unit connections to the
interfaces to dental handpieces.
This document also specifies requirements for instructions for use and technical description.
This document does not specify requirements or test methods for the effectiveness of stationary dental
unit waterline biofilm control.
NOTE Test methods for the effectiveness of stationary dental unit waterline biofilm control are specified in
ISO 16954.
This document is only applicable to stationary dental units that are not used for oral surgery treatment
requiring sterile air and water supplies. Amalgam separators are not included in this document.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft39 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Apr-2021
- 14-Dec-2022
- 11.060.20
- 11.060.25
- 2007/47/EC
- VAZ
This document specifies the general requirements and test methods for diamond rotary instruments
used in dentistry, including designation, colour code and grit sizes and a quality control for these
instruments.
It applies to all types of diamond rotary instruments independent of type and shape with exception to
diamond discs, which are specified in ISO 7711-2.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements and test methods for endodontic compactors (pluggers and
spreaders) which are used for the compaction of endodontic filling materials, and also heat-carriers
(which are not specified in the other parts of the ISO 3630 series).
This document specifies the requirements for size, marking, product designation, safety considerations,
and their labelling and packaging.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies dimensions and performance requirements for excavators used in dentistry.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and their test methods for tissue punches used with a handpiece in dentistry especially for oral surgical implant procedures such as cutting holes or notches in and removing of gingival tissue. It also specifies the requirements for their marking and labelling.
- Standard13 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and test methods for hand-held and mechanically operated
instruments used for shaping and cleaning root canals, and which are not specified in other parts of the
ISO 3630 series.
This document specifies requirements for size, marking, product designation, safety considerations,
labelling and packaging.
- Standard15 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft12 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is one of a series of standards describing the characteristics for identification cards as defined in the definitions clause and the use of such cards for international interchange.
This document specifies requirements for a high coercivity magnetic stripe (including any protective overlay) on an identification card and encoding technique. It takes into consideration both human and machine aspects and states minimum requirements.
Coercivity influences many of the quantities specified in this document but is not itself specified. The main characteristic of the high coercivity magnetic stripe is its improved resistance to erasure. This is achieved with minimal probability of damage to other magnetic stripes by contact while retaining read compatibility with magnetic stripes as defined in ISO/IEC 7811-2.
This document provides for a card capacity of approximately 10 times that of a card conforming to ISO/IEC 7811-6. The number of tracks has been increased to 6, each track being approximately half the width of tracks conforming to ISO/IEC 7811-6, located so that readers designed to read these high density tracks will also be able to read cards conforming to ISO/IEC 7811-2 and ISO/IEC 7811-6. Data is encoded in 8 bit bytes using the MFM encoding technique. Data framing is used to limit error propagation and error correction techniques further improve reliability of reading.
It is the purpose of the ISO/IEC 7811 series of standards to provide criteria to which cards shall perform. No consideration is given within these standards to the amount of use, if any, experienced by the card prior to test. Failure to conform to specified criteria is negotiated between the involved parties.
ISO/IEC 10373-2 specifies the test procedures used to check cards against the parameters specified in this document.
NOTE Numeric values in the SI and/or Imperial measurement system in this document may have been rounded off and are consistent with, but not exactly equal to each other. Using either system is correct but intermixing or reconverting values can result in errors. The original design was made using the Imperial measurement system.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft23 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and their test methods for stainless steels used in
dental instruments.
It is applicable to single-use and reusable instruments, regardless of whether they are connected to a
power-driven system or not.
It contains a current selection of stainless steels suitable for use in the manufacture of dental
instruments.