oSIST prEN ISO 24466:2022
(Main)Dentistry - Designations for the parts and dimensions of an implant body or a monopart implant (ISO/DIS 24466:2022)
Dentistry - Designations for the parts and dimensions of an implant body or a monopart implant (ISO/DIS 24466:2022)
This document defines terms for the parts of an implant body that are used in oral implantology as well
as the designation and determination of the dimensions and their data on the packaging of an oral
implant.
Four general terms for diameter (endosteal diameter, platform diameter) and length (endosteal length,
overall length) are defined and explained in examples.
Zahnheilkunde – Bezeichnungen für die Teile und Maße eines Implantatkörpers (ISO/DIS 24466:2022)
Médecine bucco-dentaire - Désignations pour les parts et les mesures des corps d'implant (ISO/DIS 24466:2022)
Zobozdravstvo - Označevanje delov in dimenzij telesa implantata ali enodelnega implantata (ISO/DIS 24466:2022)
General Information
- Status
- Not Published
- Public Enquiry End Date
- 29-Apr-2022
- Technical Committee
- VAZ - Healthcare
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 16-Feb-2022
- Due Date
- 06-Jul-2022
- Completion Date
- 03-May-2022
Overview
prEN ISO 24466 (ISO/DIS 24466:2022) - published under CEN - provides standardized designations for the parts and dimensions of an implant body or a monopart implant used in oral implantology. The standard defines uniform terminology and measurement methods for key dimensional characteristics and specifies the minimum dimensional data that manufacturers must place on the outermost packaging of dental implants. It covers both multipart (internal and external connections) and monopart implants (e.g., ball-head and conical-head designs), and clarifies bone-level and tissue-level designations.
Key Topics and Requirements
- Standardized terminology for implant parts, including: implant connective platform, internal/external connections, retention area, implant apex, transmucosal area, and retention elements.
- Primary dimensional definitions and symbols:
- Bone diameter (d) - largest diameter intended for insertion into bone (measured perpendicular to the implant’s long axis).
- Platform diameter (D) - largest diameter of the implant connective platform (measured perpendicular to the long axis).
- Implanted length (l) - distance from implant apex to implant shoulder (measured parallel to the long axis).
- Total/overall lengths (L, L_o) and transmucosal length - definitions for the most coronal points and transmucosal areas.
- Measurement rules specifying how to determine and record dimensional characteristics (directions and reference points are defined).
- Packaging and labelling requirements: manufacturers shall record platform diameter, bone diameter, total length and implanted length as nominal dimensions and indicate them on outermost packaging.
- Illustrative examples and figures for multipart implants with internal/external connections and monopart implants (ball or conical heads) to clarify application of terms.
Practical Applications and Users
This standard is practical for:
- Dental implant manufacturers - to ensure consistent product labelling and interoperable component descriptions across systems.
- Regulatory authorities and procurement - to evaluate conformity of labelling and packaged implant data.
- Clinicians and surgical teams - to reliably select implants based on standardized dimensional data (bone-level vs tissue-level, implant lengths and diameters).
- Dental laboratories and CAD/CAM workflows - for accurate prosthetic planning when using component specifications.
- Test and certification bodies - for verifying compliance with dimensional and labelling requirements.
Using ISO 24466 helps reduce ambiguity in implant specifications, supports safer surgical selection, and improves communication across manufacturers and clinicians in the dental implants supply chain.
Related Standards
- ISO 16443 - Vocabulary for dental implant systems and procedures
- ISO 1942 - Dentistry vocabulary
- ISO 15223-1 and ISO 20417 - General medical device labelling and manufacturer information
Keywords: dental implants, implant dimensions, implant body parts, platform diameter, bone diameter, implanted length, ISO 24466, implant labelling, monopart implant, multipart implant.
Frequently Asked Questions
oSIST prEN ISO 24466:2022 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Dentistry - Designations for the parts and dimensions of an implant body or a monopart implant (ISO/DIS 24466:2022)". This standard covers: This document defines terms for the parts of an implant body that are used in oral implantology as well as the designation and determination of the dimensions and their data on the packaging of an oral implant. Four general terms for diameter (endosteal diameter, platform diameter) and length (endosteal length, overall length) are defined and explained in examples.
This document defines terms for the parts of an implant body that are used in oral implantology as well as the designation and determination of the dimensions and their data on the packaging of an oral implant. Four general terms for diameter (endosteal diameter, platform diameter) and length (endosteal length, overall length) are defined and explained in examples.
oSIST prEN ISO 24466:2022 is classified under the following ICS (International Classification for Standards) categories: 11.060.15 - Dental implants. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase oSIST prEN ISO 24466:2022 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2022
Zobozdravstvo - Označevanje delov in dimenzij telesa implantata ali enodelnega
implantata (ISO/DIS 24466:2022)
Dentistry - Designations for the parts and dimensions of an implant body or a monopart
implant (ISO/DIS 24466:2022)
Zahnheilkunde – Bezeichnungen für die Teile und Maße eines Implantatkörpers
(ISO/DIS 24466:2022)
Médecine bucco-dentaire - Désignations pour les parts et les mesures des corps
d'implant (ISO/DIS 24466:2022)
Ta slovenski standard je istoveten z: prEN ISO 24466
ICS:
11.060.15 Zobni implantati Dental implants
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT INTERNATIONAL STANDARD
ISO/DIS 24466
ISO/TC 106/SC 8 Secretariat: ANSI
Voting begins on: Voting terminates on:
2022-02-10 2022-05-05
Dentistry — Designations for the parts and dimensions of
an implant body or a monopart implant
Médecine bucco-dentaire — Désignations pour les parts et les mesures des corps d'implant
ICS: 11.060.15
This document is circulated as received from the committee secretariat.
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENT AND APPROVAL. IT IS
ISO/CEN PARALLEL PROCESSING
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 24466:2022(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION. © ISO 2022
ISO/DIS 24466:2022(E)
© ISO 2022
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
ISO/DIS 24466:2022(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Multipart implant . . 2
4.1 Multipart implant with internal connection . 2
4.2 Multipart implant with external connection . 4
5 Monopart implant .5
5.1 Monopart implant with a ball head . 5
5.2 Monopart implant with a conical head . 6
6 Dimensions .7
6.1 Requirements . 7
6.2 Measurement of dimensional characteristics . 8
6.2.1 Bone diameter d . 8
6.2.2 Platform diameter D . 8
6.2.3 Implanted length l . 8
6.2.4 Total length L . 8
6.2.5 Conical implants . 8
7 Minimum data on outermost packaging . 8
7.1 General . 8
7.2 Multipart implant . 8
7.2.1 Bone level implant . 8
7.2.2 Tissue level implant . 9
7.2.3 External hex implant . 9
7.3 Monopart implant . 9
iii
ISO/DIS 24466:2022(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 106, Dentistry, Subcommittee SC 8, Dental
implants.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
ISO/DIS 24466:2022(E)
Introduction
The terms and designations used by the manufacturers of dental implants for the individual system
parts are not uniform.
As a first step all manufacturers of dent
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...