SIST EN 200:2005
(Main)Sanitary tapware - Single taps and combination taps (PN 10) - General technical specification
Sanitary tapware - Single taps and combination taps (PN 10) - General technical specification
This document specifies:
- the field of application for pillar taps, bib taps, single and multi-hole combination taps:
- for a supply system Type 1, (see Figure 1);
- for a supply system (Type 2, (see Figure 2);
- the dimensional, tightness, pressure resistance, hydraulic, mechanical strength, endurance and acoustic characteristics of nominal size 1 and 3 single taps and combination taps;
- test methods to verify the characteristics.
NOTE Tests described in this document are type tests and not quality control tests carried out during manufacture.
This document applies to draw-off taps (single taps and combination taps) for use with sanitary appliances installed in rooms used for bodily hygiene (cloakrooms, bathrooms etc.) and in kitchens i.e. for use with baths, wash basins, bidets, showers and sinks.
Figure 1 shows the supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa (0,5 to 10) bar.
Figure 2 shows the supply system of Type 2 with a pressure range of (0,01 to 1,0) MPa (0,1 to 10) bar.
This document applies to sanitary draw-off taps of nominal size 1 and 3 (PN 10).
The conditions of use and classifications are given in Table 1.
It does not cover mechanical mixing valves, thermostatic mixing valves, shower accessories or taps adapted for special use (e.g. hose union taps)
Sanitärarmaturen - Auslaufventile und Mischbatterien (PN 10) - Allgemeine technische Spezifikation
Diese Europäische Norm legt Folgendes fest:
- den Anwendungsbereich für Standventile, Wand-Auslaufventile, Einloch- und Mehrloch-Standbatterien
- für ein Versorgungssystem vom Typ 1 (siehe Bild 1);
- für ein Versorgungssystem vom Typ 2 (siehe Bild 2);
- die Maße, die Anforderungen an die Dichtheit, die Festigkeit unter Innendruck, die hydraulischen Eigenschaften, die mechanische Festigkeit und Dauerfestigkeit sowie das Geräuschverhalten von Auslaufventilen und Mischbatterien der Nenngrößen 1 und -;
- die Prüfverfahren, um diese Anforderungen zu überprüfen.
ANMERKUNG Die in dieser Norm beschriebenen Prüfungen sind Typprüfungen und nicht für die Fertigungskontrolle vorge-sehen.
Diese Europäische Norm gilt für Entnahmearmaturen (Auslaufventile und Mischbatterien) zur Verwendung mit Sanitärausstattungsgegenständen, die in den der Hygiene dienenden Räumen (Toiletten, Bäder usw.) und in Küchen installiert werden, z. B. für Badewannen, Waschbecken, Sitzwaschbecken, Duschen und Spülbecken.
Bild 1 zeigt das Versorgungssystem vom Typ 1 mit einem Druckbereich von (0,05 bis 1,0) MPa [(0,5 bis 10) bar].
Bild 2 zeigt das Versorgungssystem vom Typ 2 mit einem Druckbereich von (0,01 bis 1,0) MPa [(0,1 bis 10) bar].
Diese Europäische Norm gilt für Sanitärarmaturen der Nenngrößen 1 und 3 (PN 10).
Die Anwendungsbedingungen und Klassifizierungen sind in Tabelle 1 enthalten.
Diese Europäische Norm gilt nicht für mechanisch einstellbare Mischer, thermostatische Mischer, Brausenzubehör oder Armaturen für besondere Einsatzfälle (z. B. Auslaufventile mit Schlauchanschluss) oder Ablaufventile jeglicher Bauart.
Robinetterie sanitaire - Robinets simples et mélangeurs (PN 10) - Spécifications techniques générales
La présente Norme européenne spécifie :
3 le domaine d'application des robinets de puisage, des robinets simples, des mélangeurs simples et combinés :
3 pour un systeme d'alimentation (Type 1, voir Figure 1) ;
3 pour un systeme d'alimentation (Type 2, voir Figure 2) ;
3 les caractéristiques dimensionnelles, d'étanchéité, de comportement mécanique sous pression, hydrauliques, de résistance et d'endurance mécaniques et acoustiques auxquelles doivent répondre les robinets simples et mélangeurs de dimension nominale 1 et 3 ;
3 les méthodes d'essai permettant de contrôler ces caractéristiques.
NOTE Les essais décrits dans la présente Norme sont des essais de type et non des essais de contrôle de la qualité, qui sont réalisés en cours de fabrication.
La présente Norme internationale s'applique aux robinets de puisage (robinets simples et mélangeurs) destinés a l'équipement des appareils sanitaires installés dans les locaux d'hygiene corporelle (toilettes, salles de bain, etc.) et dans les cuisines, exemples d'utilisation sur des baignoires, lavabos, bidets, douches et éviers.
La Figure 1 illustre le systeme d'alimentation de Type 1 avec une plage de pression (de 0,05 a 1,0) MPa (de 0,5 a 10) bar.
La Figure 2 illustre le systeme d'alimentation de type 2 avec une plage de pression (de 0,01 a 1,0) MPa (de 0,1 a 10) bar.
La présente Norme internationale s'applique aux robinets de puisage de dimension nominale 1 et 1 (PN 10).
Les conditions de fonctionnement et les classifications sont indiquées dans le Tableau 1.
Elle ne s'applique pas aux robinets mitigeurs mécaniques, aux robinets mitigeurs thermostatiques, aux accessoires de douche ou aux robinets destinés a une utilisation particuliere (ex : robinets équipés d'un flexible sur le nez).
Sanitarne armature - Enojne pipe in kombinirane pipe (PN 10) - Splošne tehnične zahteve
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 200:2005
01-marec-2005
1DGRPHãþD
SIST EN 200:1996
6DQLWDUQHDUPDWXUH(QRMQHSLSHLQNRPELQLUDQHSLSH316SORãQHWHKQLþQH
]DKWHYH
Sanitary tapware - Single taps and combination taps (PN 10) - General technical
specification
Sanitärarmaturen - Auslaufventile und Mischbatterien (PN 10) - Allgemeine technische
Spezifikation
Robinetterie sanitaire - Robinets simples et mélangeurs (PN 10) - Spécifications
techniques générales
Ta slovenski standard je istoveten z: EN 200:2004
ICS:
91.140.70 Sanitarne naprave Sanitary installations
SIST EN 200:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 200
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2004
ICS 91.140.70 Supersedes EN 200:1989
English version
Sanitary tapware - Single taps and combination taps (PN 10) -
General technical specification
Robinetterie sanitaire - Robinets simples et mélangeurs Sanitärarmaturen - Auslaufventile und Mischbatterien (PN
(PN 10) - Spécifications techniques générales 10) - Allgemeine technische Spezifikation
This European Standard was approved by CEN on 8 August 2004.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 200:2004: E
worldwide for CEN national Members.
---------------------- Page: 2 ----------------------
EN 200:2004 (E)
Contents Page
Foreword.4
1 Scope .6
2 Normative references .10
3 Designation .10
4 Marking and identification .11
4.1 Marking .11
4.2 Identification.12
5 Materials .12
5.1 Chemical and hygiene requirements.12
5.2 Exposed surface conditions.12
6 Dimensional characteristics .12
6.1 General remarks.12
7 Leaktightness characteristics .20
7.1 General.20
7.2 Test methods.20
7.2.1 Principle.20
7.3 Apparatus .20
7.4 Leaktightness of the obturator and of the tap upstream of the obturator.20
7.4.1 Procedure .20
7.4.2 Requirements.21
7.5 leacktightness of the tap downstream of the obturator .21
8 Pressure resistance characteristics -mechanical performance under pressure.25
8.1 General.25
8.2 Principle.25
8.3 Apparatus .25
8.4 Mechanical behaviour upstream - Obturator in the closed position.25
8.4.1 Procedure .25
8.4.2 Requirement.26
8.5 Mechanical behaviour downstream - Obturator in the open position.26
9 Hydraulic characteristics .27
9.1 General.27
9.2 Test method.27
9.2.1 Principle.27
9.2.2 Apparatus .27
9.2.3 Procedure .27
9.3 Requirement.27
10 Mechanical strength characteristics - torsion test for operating mechanism .28
10.1 General.28
10.2 Test method.29
10.2.1 Principle.29
10.2.2 Apparatus .29
10.2.3 Test piece .29
10.2.4 Requirement.29
11 Mechanical endurance characteristics.29
11.1 Mechanical endurance characteristics of the operating mechanism .29
11.1.1 General.29
11.1.2 Test method.29
2
---------------------- Page: 3 ----------------------
EN 200:2004 (E)
11.1.3 Procedure .30
11.1.4 Requirement.30
11.2 Mechanical endurance of diverters .31
11.2.1 General.31
11.2.2 Test method .31
11.2.3 Procedure .31
11.2.4 Requirement.32
11.3 Mechanical endurance of swivel spouts (single and divided outlet type).33
11.3.1 General.33
11.3.2 Test method .33
11.3.3 Procedure divided outlet type .34
11.3.4 Procedure single outlet type .34
11.3.5 Requirements.34
12 Backflow protection .35
13 Acoustic characteristics .35
13.1 General.35
13.2 Procedure .35
13.3 Requirements.35
13.3.1 Flow rate class of draw-off taps.35
13.3.4 Expression of results .36
13.3.5 Determination of acoustic group .36
Annex A (informative) Pressure take-off tee.39
Bibliography.44
3
---------------------- Page: 4 ----------------------
EN 200:2004 (E)
Foreword
This document (EN 200:2004) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the
secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by June 2005, and conflicting national standards shall be withdrawn at the latest by
June 2005.
This document supersedes EN 200:1989.
This document acknowledges the field of application of tapware used in:
water supply systems of Type 1 (see Figure 1 and Table 1) with a pressure range of 0,05 MPa (0,5 bar) to
1,0 MPa (10 bar);
water supply systems of Type 2 (see Figure 2 and Table 1) with a pressure range of 0,01 MPa (0.,1 bar) to
1,0 MPa (10 bar) – which combines mains-fed and cistern-fed water supply systems.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
4
---------------------- Page: 5 ----------------------
EN 200:2004 (E)
Introduction
In respect of potential adverse effects on the quality of water intended for human consumption, caused by the
product covered by this document.
This document provides no information as to whether the product may be used without restriction in any of the
Member States of the EU or EFTA.
It should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations
concerning the use and/or the characteristics of these products remain in force.
5
---------------------- Page: 6 ----------------------
EN 200:2004 (E)
1 Scope
This document specifies:
the field of application for pillar taps, bib taps, single and multi-hole combination taps:
for a supply system Type 1, (see Figure 1);
for a supply system (Type 2, (see Figure 2);
the dimensional, tightness, pressure resistance, hydraulic, mechanical strength, endurance and acoustic
characteristics of nominal size ½ and ¾ single taps and combination taps;
test methods to verify the characteristics.
NOTE Tests described in this document are type tests and not quality control tests carried out during manufacture.
This document applies to draw-off taps (single taps and combination taps) for use with sanitary appliances installed
in rooms used for bodily hygiene (cloakrooms, bathrooms etc.) and in kitchens i.e. for use with baths, wash basins,
bidets, showers and sinks.
Figure 1 shows the supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa (0,5 to 10) bar.
Figure 2 shows the supply system of Type 2 with a pressure range of (0,01 to 1,0) MPa (0,1 to 10) bar.
This document applies to sanitary draw-off taps of nominal size ½ and ¾ (PN 10).
The conditions of use and classifications are given in Table 1.
It does not cover mechanical mixing valves, thermostatic mixing valves, shower accessories or taps adapted for
special use (e.g. hose union taps)
6
---------------------- Page: 7 ----------------------
EN 200:2004 (E)
Table 1 — Conditions of use/Classifications
Flow rate
Operating range of taps Acoustics Marking
Water Supply
classes
system
Limits Recommended
See Table 10 See Clause 13 See Clause 4
Dynamic Pressure Z ≤ 0,15 l/s for example
I / A
> 0,05 MPa Dynamic Pressure A ≤ 0,25 l/s
Type 1 (0,1 to 0,5) MPa II / BC
(0,5 bar) S ≤ 0,33 l/s Group I -
Static Pressure (1.0 to 5,0) bar
see Figure 1 B ≤ 0,42 l/s
a
≤ 1,0 MPa Group II – I./-
* see note b) C ≤ 0,50 l/s
a
(10,0 bar) II./-
D ≤ 0,63 l/s
Dynamic Pressure See Table 8
Dynamic Pressure
> 0,01 MPa
(0,01 to 0,2) MPa
X ≤ 0,125 l/s X
Type 2
(0,1 bar) -Note c)
(0,1 to 2,0) bar
Y ≤ 0,250 l/s Y
Static Pressure (unclassified)
see Figure 2
R
* see note b) R ≤ 0,125/
≤ 1,0 MPa
0,070 l/s
(10,0 bar)
Temperature
≤ 90 °C Lower limit: as for installation < 65 °C
a
Without flow rate class: Taps without interchangeable outlet accessories are tested with the original outlet accessories of
the manufacturer and not marked with a flow rate class.
b
Measured at the shower outlet when incorporated.
c
There is usually no acoustic classification for taps used in supply systems of type 2 and no specifications governing the
level of noise emissions from these water installations.
If supply pressures are such that excessive noise is generated it is recommended that pressure or flow regulators are fitted
in the system, or where practicable, taps conforming to the appropriate acoustic classification given in 13.3.5 are used.
NOTE If Taps are used at dynamic pressures outside the recommended operating range consideration should be given to
the following characteristics:
the force required to operate the tap and diverter;
diverter operation and flow rate;
mechanical wear;
acoustical performance.
Take notice of:
Issue Supply system Type 1 Supply system Type 2
Taps for type 2 systems having rapid action
Operational Force mechanisms may require a higher operating
force
Taps for type 1 systems with automatic diverters
Taps for type 2 systems may require more
Diverter Operation may not hold in the shower mode due to low
operational force
dynamic supply pressure.
Taps for type 2 systems may result in Taps for type 1 systems may not provide an
Flow Performance
excessive flow velocities acceptable rate of flow
National regulations may require an
acoustically classified Tap to be specified.
Noise
Taps for type 1 and 2 systems may result in
excessive noise when used above the
recommended max pressure
7
---------------------- Page: 8 ----------------------
EN 200:2004 (E)
Key
1 Cold water
2 Hot water
3 Mains supply pipe (Supply pressures up to 10 bar)
4 Water heater
Figure 1 — Supply system type 1 - with a pressure range of (0,05 to 1,0) MPa (0,5 to 10) bar.
8
---------------------- Page: 9 ----------------------
EN 200:2004 (E)
Key
1 Cold water storage cistern (cover omitted for clarity)
2 Warning pipe
3 Vent pipe
4 Hot water cylinder
5 Alternative cistern fed cold supply to sanitary appliances
6 To boiler
7 Mains supply pipe (Supply pressures up to 10 bar)
Figure 2 — Type 2-Supply system - with a pressure range of (0,01 to 1,0) MPa, (0,1 to 10) bar A vented
domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and
alternative gravity cold water supply to sanitary appliances
9
---------------------- Page: 10 ----------------------
EN 200:2004 (E)
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 246, Sanitary tapware – General specifications for flow rate regulators.
EN 248, Sanitary tapware – General specification for electrodeposited coatings of Ni-Cr.
EN 1112, Shower outlets for (PN 10) sanitary tapware.
EN 1113, Showers hoses for (PN 10) sanitary tapware.
EN 1717, Protection against pollution of potable water in water installations and general requirements of devices to
prevent pollution by backflow.
prEN 13618, Water supply – Flexible hoses (elastomeric or plastic material hose with or without metallic or
synthetic braiding) – Product standard.
EN 13904, Low resistance shower outlets for sanitary tapware.
EN 13905, Low resistance shower hoses for sanitary tapware.
EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions,
tolerances and designation (ISO 228-1:2000).
EN ISO 3822-1, Acoustics: Laboratory tests on noise emission from appliances and equipment used in water
supply installations – Part 1: Method of measurement (ISO 3822-1:1999).
EN ISO 3822-2, Acoustics: Laboratory tests on noise emission from appliances and equipment used in water
supply installations – Part 2: Mounting and operating conditions for draw-off taps and mixing valves
(ISO 3822-2:1995).
EN ISO 3822-3, Acoustics – Laboratory tests on noise emission from appliances and equipment used in water
supply installations – Part 3: Mounting and operating conditions for in-line valves and appliances
(ISO 3822-3:1997).
EN ISO 3822-4, Acoustics: Laboratory tests on noise emission from appliances and equipment used in water
supply installations – Part 4: Mounting and operating conditions for special appliances (ISO 3822-4:1995).
3 Designation
The taps covered by this document are designated (see Table 2) by reference to:
supply system of Type 1 or Type 2 (see Table 1);
nominal size (½ or ¾);
this document.
For example: combination tap, nominal size ½, 2-hole with combined visible body, mounting on horizontal surface,
diverter, fixed outlet, flow rate class(es), with acoustic group, EN.
10
---------------------- Page: 11 ----------------------
EN 200:2004 (E)
Table 2 — Designation
Tapware according to application (see Table 1)
Type of tap Pillar or bib tap or combination tap (see Figure 3)
Intended use Basin, bidet, sink, bath or shower
Mounting method Horizontal or vertical surfaces
Body Single or multi-hole, visible, or concealed
Diverter with or without diverter
Fixed-, moveable-, divided outlet spout, with or without
Type of outlet
flow rate regulator
Acoustic group and classification
Taps for system type 1
Group I, or group II, or unclassified
Taps for system type 2
Flow rate class of taps
Supply system type 1 Z, A, S, B, C, D
Supply system type 2 X, Y, R
Ref. to the European
EN 200
Standard
4 Marking and identification
4.1 Marking
4.1.1 Taps for a supply system Type 1 shall be marked permanently and legibly with:
manufacturer's or agent’s name or identification - on the body or handle;
manufacturer's name or identification - on the headwork;
acoustic group (see Table 11) and the flow rate class(es) (see Table 10) - on the body.
NOTE Marking of flow rate class(es) is only necessary if the tap has provision for connecting an interchangeable outlet
accessory and is tested with a standard low-noise flow resistance specified in Table 10.
Examples of marking:
Name or identification and I/A, or II/A (acoustic group and flow rate class(es) see Table 10).
Name or identification and I/-, or II/- (acoustic group, without flow rate class(es)).
Name or identification and I/CA, or II/CA (Bath/Shower tap; the first letter for the bath outlet, the second letter
for the shower outlet).
4.1.2 Taps for a supply system Type 2 shall be marked permanently and legibly with:
manufacturer's or agent’s name or identification - on the body or handle;
manufacturer's name or identification - on the headwork;
11
---------------------- Page: 12 ----------------------
EN 200:2004 (E)
flow rate class(es), (see Table 1 ), - on the body.
Example of marking:
Name or identification and X, Y, or R, (flow rate class(es) X, Y, or R see Table 8).
4.2 Identification
4.2.1 The control devices for the taps shall be identified:
for cold water by the colour blue or word/letters for cold;
for hot water by the colour red or word/letters for hot.
4.2.2 The cold water control device shall be on the right and the hot water control device on the left, when
viewed from the front.
4.2.3 Vertical arrangements of control devices require the hot water control device to be on top.
4.2.4 In the case of divided outlet combination taps for supply systems type 2 (with mains fed on cold inlet) which
give cold water flow rates at 0,01 MPa (0,1 bar) of less than 7,5 l/min the cold-water inlet shall be colour coded
blue, e.g. using coloured tape, disks or paint.
5 Materials
5.1 Chemical and hygiene requirements
All materials coming into contact with water intended for human consumption shall present no health risk up to a
temperature of 90 °C.
They shall not cause any change of the drinking water in terms of quality, appearance, smell or taste.
5.2 Exposed surface conditions
Visible chromium plated surfaces and Ni-Cr coatings shall comply with the requirements of EN 248.
6 Dimensional characteristics
6.1 General remarks
The design and construction of components without defined dimensions permits various design solutions to be
adopted by the manufacturer.
Special cases are covered in 6.5.
6.2 Inlet dimensions (- shanks, connections, tubes, attachments) are shown in Table 3, Figures 3, 4 and 5.
6.3 Outlet dimensions (- length, flow rate regulators, attachments) are shown in Table 4, Figures 6, 7 and 8.
6.4 Mounting dimensions of taps described in this document are shown in Table 5, Figures 9, 10 and 11.
12
---------------------- Page: 13 ----------------------
EN 200:2004 (E)
Table 3 — Inlet dimensions (Pillar & bib taps, single & Multi-hole combination taps)
INLET – DIMENSIONS ( all dimensions are in mm ) COMMENTS
Shank, Union, Bib tap, Captive nut, (useful thread length)
A G ½ B
Shank, union In accordance with EN ISO 228-1
A 1 G ¾ B
A 2 9 min Captive nut
A 3 15 min Shank, Union (straight or eccentric)
Useful thread length
A 6 11 min Bib tap size ½
A 7 14 min Bib tap size ¾
Connecting centres
G Supply connection, Straight unions
150 + 1
2 - hole wall -mounted size ½
- with eccentric unions (extension of this
G 1 140 – 160
range is permitted)
G 2 200 + 3,5 Multi-hole combination tap
G 3 180 + 5 Multi-hole combination tap
Inlet connections
N 1 12,3 + 0,2
Type 1 size ½
N 2 5 min
N 1 15,2 + 0,05 Type 2 size ½
30° chamfer/flat 0,3
N 2 13 min
N 1 14.7 + 0,3
Type 3 size ½
N 2 6,4 min
N 1 19.9 + 0,3
Type 3 size ¾
N 2 6,4 min
Plain end ∅ 10 or 12 or 15 or G ½ or
T Copper tube(s) or flexible hose(s)
G 3/8 male or female
Tube(s) or flexible hose(s)
U 350 min
Flex. Hoses in accordance with
prEN 13618
13
---------------------- Page: 14 ----------------------
EN 200:2004 (E)
INLET DIMENSIONS
Key
1 Plain tube
Figure 3 — Bib tap ½ and ¾ - Single hole taps ½
Figure 4 — Multi-hole combination taps
14
---------------------- Page: 15 ----------------------
EN 200:2004 (E)
Figure 5 — Supply connections
Table 4 — Outlet dimensions (Outlets, pillar and bib taps, single and multi -hole combination taps)
OUTLET – DIMENSIONS (Dimensions are in millimetres) COMMENTS
Dimension from lowest point of the outlet
orifice including any flow rate regulator
Outlet Orifice
or flow straightener to the mounting
E 25 min - Lowest point surface. For a period of 5 years following
approval at final vote a value of 20mm is
- All taps and outlets
acceptable for size ½ taps for type 2
systems.
D 80 min Pillar tap ½, ¾, Bib tap
67 min Pillar tap ½ for Type 2 systems Dimension from the centre of outlet
orifice including any flow rate regulator
or flow straightener.
D 1 90 min Horizontal mounted combination tap
Wall mounted combination tap
D 3 115 min
Separate spout
A G ½ B
Shower outlet In accordance with EN ISO 228-1
A 1 G ¾ B
A 4 7,5 min Useful thread length
Shower outlet
A 5 9,5 min Free length of connection
Nozzle outlets to accept flow rate regulators shall be in accordance with EN 246.
(Those not in accordance with EN 246, are covered by 6.5)
15
---------------------- Page: 16 ----------------------
EN 200:2004 (E)
OUTLET DIMENSIONS
1 2
Key
1 Pillar tap
2 Bib tap
Figure 6 — Pillar and bib taps
16
---------------------- Page: 17 ----------------------
EN 200:2004 (E)
Figure 7 — Outlet Figure 8 — Single hole combination tap
17
---------------------- Page: 18 ----------------------
EN 200:2004 (E)
Table 5 — Mounting dimensions
(Outlets, pillar and bib taps, single and multi-hole combination taps)
MOUNTING – DIMENSIONS COMMENTS
Shank diameter
H 1 24 max Two hole combination taps size ½ - fixed centres
Pillar tap size ½, separate outlet, side spray, 3 hole
H 2 29 max
combination tap size ½ - adjustable centres
Single hole combination tap
H 3 33,5 max Pillar tap size ¾, Two hole combination tap size ¾
3- hole combination tap size ½ & ¾
Base or flange
42 min Pillar tap size ½
J
50 min
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.