(Main)Aerospace series - Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak - Part 001: Technical specification
Aerospace series - Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak - Part 001: Technical specification
This European Standard specifies the general characteristics, the conditions for qualification acceptance and quality assurance, and the test programs and groups for threaded ring coupling circular connectors, fire-resistant or non fire-resistant, intended for use in a temperature range from 65 °C to 175 °C continuous, 200 °C continuous or 260 °C peak according to the classes and models.
Luft- und Raumfahrt - Elektrische Rundsteckverbinder mit Schraubkupplung, feuerbeständig oder nicht feuerbeständig, Betriebstemperaturen - 65 °C bis 175 °C konstant, 200 °C konstant, 260 °C Spitze - Teil 001: Technische Lieferbedingungen
Série aérospatiale - Connecteurs électriques circulaires à accouplement par bague filetée, résistant au feu ou non, températures d'utilisation – 65 °C à 175 °C continu, 200 °C continu, 260 °C en pointe - Partie 001: Spécification technique
Aeronavtika - Konektorji, električni, okrogli, priključeni z navojnim obročkom, odporni ali neodporni proti ognju, s stalno delovno temperaturo med –65 °C in 175 °C, 200 °C, najvišjo 260 °C - 001. del: Tehnična specifikacija
Ta evropski standard določa splošne značilnosti, pogoje kvalifikacije, sprejemljivosti in zagotavljanja kakovosti ter preskusne programe in skupine za okrogle konektorje, priključene z navojnim obročkom, ognjevzdržne ali ne ognjevzdržne, za uporabo pri stalnih temperaturah med 65 °C in 175 °C, pri stalni temperaturi 200 °C ali pri najvišji temperaturi 260 °C, odvisno od razreda in modela.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Rundsteckverbinder mit Schraubkupplung, feuerbeständig oder nicht feuerbeständig, Betriebstemperaturen - 65 °C bis 175 °C konstant, 200 °C konstant, 260 °C Spitze - Teil 001: Technische LieferbedingungenSérie aérospatiale - Connecteurs électriques circulaires à accouplement par bague filetée, résistant au feu ou non, températures d'utilisation – 65 °C à 175 °C continu, 200 °C continu, 260 °C en pointe - Partie 001: Spécification techniqueAerospace series - Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak - Part 001: Technical specification49.060Aerospace electric equipment and systems31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN 2997-001:2017SIST EN 2997-001:2017en,fr,de01-september-2017SIST EN 2997-001:2017SLOVENSKI
STANDARDSIST EN 2997-001:20111DGRPHãþD
SIST EN 2997-001:2017
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 2997-001
June
t r s y ICS
v {ä r x r Supersedes EN
t { { yæ r r sã t r s sEnglish Version
Aerospace series æ Connectorsá electricalá circulará coupled by threaded ringá fireæresistant or non fireæresistantá operating temperatures æ
x w
¹C to
s y w
¹C continuousá
t r r
¹C continuousá
t x r
¹C peak æ Part
r r sã Technical specification Série aérospatiale æ Connecteurs électriques circulaires à accouplement par bague filetéeá résistant au feu ou noná températures d 5utilisation æ
x w
¹C à
s y w
¹C continuá
t r r
¹C continuá
t x r
¹C en pointe æ Partie
r r sã Spécification technique
Luftæ und Raumfahrt æ Elektrische Rundsteckverbinder mit Schraubkupplungá feuerbeständig oder nicht feuerbeständigá Betriebstemperaturen æ
x w
¹C bis
s y w
¹C konstantá
t r r
¹C konstantá
t x r
¹C Spitze æ Teil
r r sã Technische Lieferbedingungen This European Standard was approved by CEN on
x February
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
t { { yæ r r sã t r s y ESIST EN 2997-001:2017
EN 2997-001:2017 (E) 2 Contents Page European foreword . 3 Introduction . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 6 4 Description . 6 5 Design . 8 6 Definition drawings and masses . 9 7 Tests . 44 8 Quality assurance . 59 9 Designation and marking . 70 10 Delivery conditions . 71 11 Packaging . 71 12 Storage . 72
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 3 European foreword This document (EN 2997-001:2017) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2017, and conflicting national standards shall be withdrawn at the latest by December 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 2997-001:2011. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 4 Introduction This family of connectors is derived from MIL-DTL-83723 series III, type T which it is intermateable with. It is particularly suitable for use on aircraft engines and in zones of severe environmental conditions on board aircraft, applying EN 2282. These connectors are distinguishable from MIL-DTL-83723 by: a) the mechanical stop for coupling being achieved manually; b) the coupling system having a self-locking nut that features a greater resistance to decoupling; c) the variety of the functional classes and models, including models with integrated cable outlets. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 5 1 Scope This European Standard specifies the general characteristics, the conditions for qualification acceptance and quality assurance, and the test programs and groups for threaded ring coupling circular connectors, fire resistant or non-fire resistant, intended for use in a temperature range from − 65 °C to 175 °C continuous, 200 °C continuous or 260 °C peak according to the classes and models. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2267-002, Aerospace series — Cables, electrical, for general purpose — Operating temperatures between − 55 °C and 260 °C — Part 002: General EN 2282, Aerospace series — Characteristics of aircraft electrical supplies EN 2346-002, Aerospace series — Cable, electrical, fire resistant — Operating temperatures between − 65 °C and 260 °C — Part 002: General EN 2591 (all parts), Aerospace series — Elements of electrical and optical connection — Test methods EN 2997 (all parts), Aerospace series — Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non-fire resistant, operating temperatures − 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak EN 3155-001, Aerospace series — Electrical contacts used in elements of connection — Part 001: Technical specification EN 3197, Aerospace series — Design and installation of aircraft electrical and optical interconnection systems EN 3660-003, Aerospace series — Cable outlet accessories for circular and rectangular electrical and optical connectors — Part 003: Grommet nut, style A for EN 2997 and EN 4067 — Product standard EN 3660-004, Aerospace series — Cable outlet accessories for circular and rectangular electrical and optical connectors — Part 004: Cable outlet, style A, straight, unsealed with clamp strain relief for EN 2997 and EN 4067 — Product standard EN 3660-033, Aerospace series — Cable outlet accessories for circular and rectangular electrical and optical connectors — Part 033: Band — Product standard 1) EN 3909, Aerospace series — Test fluids for electrical and optical components and sub-assemblies
1) In preparation at the date of publication of this standard. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 6 EN 4067 (all parts), Aerospace series — Connectors, electrical, circular, scoop-proof, coupled by threaded ring, fire-resistant, operating temperature 260 °C peak EN 4529-003, Aerospace series — Elements of electrical and optical connection — Sealing plugs — Part 003: Class T — Product standard EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace standard parts ISO 263, ISO Inch screw threads — General plan and selection for screws, bolts and nuts — Diameter range 0,06 to 6 in MIL-HDBK-454B, General guidelines for electronic equipment 2) MIL-DTL-83723, Connector, electrical circular, environment resistant, receptacles and plugs, general specification for 2) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 2591-100 apply. 4 Description 4.1 General Different variants of materials, housings and contact arrangements are provided according to the model and class. These connectors use crimp or solder contacts of sizes 22, 20, 16 and 12. The receptacles and plugs contain either male contacts or female contacts. The contacts fitted in the classes Y and YE receptacles are exclusively of the male non-removable solder type. The connectors are polarized by means of keyways and keys; polarization shall be obtained before the male contacts enter the insert of the female contacts and before the coupling ring is engaged. The position of the keying arrangement is given in Table 5. Masking of the blue colour band on the receptacle provides visual indication of full coupling. Only the connectors housing sizes 8, 10 and 12 with size 22 contacts are mechanical scoop proof.
2) Published by: Defense Logistic Agency (DLA), http://www.dscc.dla.mil/Programs/MilSpec/ SIST EN 2997-001:2017
EN 2997-001:2017 (E) 7 4.2 Receptacle The receptacle may be attached by: • square flange; • the jam-nut with O-ring sealing; for spare parts, see EN 2997-002; • round flange for attachment by soldering/brazing/welding, classes Y and YE only. The receptacle contains five keyways into which the keys of the plug engage. The main keyway is fixed and is wider than the others. Polarization is ensured by different positions of the secondary keyways. The position of the insert is fixed relative to the main keyway. 4.3 Plug The plug contains five keys, which engage in the keyways of the receptacle. The main key is wider than the others. Polarization is ensured by different positions of the secondary keys. The position of the insert is fixed relative to the main key. The coupling ring permanently fitted on the plug enables the connectors to be coupled and uncoupled. The coupling torque shall be at least 50 % lower than the uncoupling torque. The internal thread of the coupling ring may be treated during manufacture with a suitable lubricant compatible with the performance required in this standard. The plug of classes S, SE, SF, SV, RS and WS is fitted with a grounding spring device ensuring electrical continuity between the coupled connector housings. 4.4 Materials and surface treatment 4.4.1 General When dissimilar metals are in close contact, adequate protection against corrosion shall be used for the electromotive force of the cell not to exceed 0,25 V (see EN 3197). 4.4.2 Housings The material of the housing for the connectors and for the fittings may either be passivated stainless steel or aluminium alloy protected against corrosion by nickel or cadmium plating (see EN 2997-002). 4.4.3 Contacts Unless otherwise specified, the contacts shall be in ferrous alloy for classes Y and YE and in copper alloy for the other models. The contacts for classes Y and YE shall be gold-plated on an appropriate undercoat (silver undercoat shall not be used). Selective protection is authorized provided that it is sufficient to ensure that performance is not affected. Measurement of the thickness of the protective treatment shall be effected in accordance with EN 2591-508. For removable contacts, see EN 2997-002. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 8 4.4.4 Non-metallic materials The materials used for insert, seals and grommets shall have hardness and mechanical and electrical characteristics consistent with the required use. 5 Design 5.1 Housings The connector housings shall be in one unit. They shall contain teeth at the rear over the entire periphery and shall accommodate the cable outlet accessory and other fittings except for connectors with integrated cable outlet. The receptacle shall furthermore be fitted with an O-ring seal for sealing the coupled housings. Receptacles for attachment by nut shall contain an O-ring seal. The nut shall have holes for the passage of locking wire. The threads shall conform to ISO 263. The coupling ring shall be designed so that the male and female contacts engage when it is rotated clockwise and disengage when it is rotated anti clockwise. The coupling ring shall be knurled to aid gripping by hand. On completion of tightening of the coupling ring, mechanical metal to metal contact shall exist between the receptacle and the plug mating faces, indicated by masking of the blue colour band (see Figure 1). The cable outlet accessories shall compress the grommet of the connectors without twisting it. A blue colour band indicating that the crimp contacts of the connectors are intended for rear removal shall be provided: • behind the flange of the receptacles with square flange; • on the flange of receptacles with jam nut attachment; • on the coupling ring of the plugs. The position of the blue colour bands shall be such that at least one of them is visible at all times on the coupling ring of the plug. 5.2 Inserts The insert carrying the male and female contacts shall be in hard material and have a cross section and radii such that no cracks, flaking or breaks can occur in normal operation. The insert for contacts shall be non-removable; it shall be mechanically held in the housing. Sealing shall be provided between the housing and insert. The front face of the insert shall be such that sealing is ensured when the connectors are coupled. The interfacial seal of the insert of the male contacts shall be bonded on the hard insert. The grommet shall permit sealing for all cable diameters indicated in EN 2997-002 and shall not be removable. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 9 The mechanical contacts retention system shall be integrated in the hard insert. The design of non-hermetic connectors shall permit individual installation of the contacts without removal of the insert or grommet. Insertion and removal of the contacts shall be from the rear with the tools specified in the product standards. 6 Definition drawings and masses 6.1 General The general dimensions and the masses of receptacles, plugs and protective covers are given in the product standards. 6.2 Receptacle mating dimensions The mating dimensions of receptacles are shown in Figures 1 and 2 including details A, B, C and D as well as in Tables 1 and 2.
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 10 Dimensions and tolerances are in millimetres.
Key 1 Thread 5 Hard insert 6 Interfacial seal 7 Optional shape 8 Flat ∅N 9 Blend radius a To rear of colour band b Depth of keyways 2 Blue coloured band minimum width 0,64 3 Seal diameter housing size 08 : 1,42 ±=0,08=ho×sing=sizes=10=to=28=Ω=1,78=±=0,08=4=Ho×sing=08Ω=12,37=12,12=Othe±=ho×singsΩ=12,57=12,32=Figure 1
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 11 Dimensions and tolerances are in millimetres.
Key 1 Thread 5 Hard insert 6 Interfacial seal 7 Optional shape a To rear of colour band b Depth of keyways 2 Blue coloured band minimum width 0,64 3 Seal diameter housing size 08 : 1,42 ±=0,08=ho×sing=sizes=10=to=12=Ω=1,78=±=0,08=4=Ho×sing=08Ω=12,37=12,12=Ho×sings=10=an≤=12Ω=12,57=12,32=Figure 2 — Only for housings 8, 10 and 12 for size 22 contact
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 12 Table 1 — Mating dimensions for receptacle Housing size Thread Class 2A a ØC ØD max. ØS T ØF max. 08 0.5625 - 24 UNEF 10,62 10,49 7,37 12,58 12,45 1,93 1,80 14,27 10 0.6875 - 24 UNEF 13,59 13,46 10,37 16,28 16,15 2,26 2,13 17,67 12 0.8750 - 20 UNEF 17,91 17,78 14,69 20,60 20,47 22,22 14 0.9375 - 20 UNEF 19,66 19,53 16,44 22,35 22,22 23,77 16 1.0625 - 18 UNEF 22,89 22,76 19,67 25,58 25,45 26,97 18 1.1875 - 18 UNEF 25,58 25,45 22,36 28,27 28,14 30,15 20 1.3125 - 18 UNEF 28,75 28,63 25,54 31,45 31,32 33,32 22 1.4375 - 18 UNEF 31,93 31,80 28,71 34,62 34,49 36,49 24 1.5625 - 18 UNEF 35,10 34,98 31,88 37,80 37,67 39,67 28 1.8125 - 16 UN 41,45 41,32 38,23 44,15 44,02 46,02 a ISO 263.
Table 2 — Mating dimensions for receptacle Contact size ØG a
ØM ØU b
ØV ØW ØX a max. ØZ ØN 22 1,70 1,60 0,97 0,89 0,94 0,84 1,35 1,27 1,88 1,75 – 0,79 0,76 – 20 3,00 2,90 1,50 1,24 1,17 1,07 2,28 2,14 2,38 2,28 3,00 1,04 0,99 0,51 0,13 16 3,81 3,71 2,06 1,80 1,75 1,65 2,88 2,73 2,98 2,88 3,81 1,61 1,56 0,81 0,43 12 5,33 5,22 2,84 2,54 2,57 2,46 3,85 3,68 3,95 3,85 5,33 2,41 2,36 1,57 1,19 a For contact arrangements 08-03 and 10-06, G = 2,342,44, X max. = 2,44. b Dimension U does not apply to hermetic receptacles.
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 13 6.3 Plug mating dimensions The mating dimensions of plugs are shown in Figures 3 and 4 including details A, B, C, and detail D of Figure 1 and in Tables 2 and 3. Dimensions and tolerances are in millimetres.
Key 1 Thread 2 Blue colour band minimum width 0,64 position optional 3 Optional shape 4 See detail D in Figure 1 5 Interfacial seal 6 Hard insert 7 Grounding spring system a Thread engagement b Front of the contact c Classes S, SE, SF, SV, RS and WS Figure 3
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 14 Dimensions and tolerances are in millimetres.
Key 1 Thread 2 Blue colour band minimum width 0,64 position optional 3 Optional shape 4 See detail D in Figure 2 5 Interfacial seal 6 Hard insert 7 Grounding spring system a Thread engagement b Front of the contact c Classes S, SE, SF, SV, RS and WS Figure 4 — Only for housings 8, 10 and 12 for size 22 contact SIST EN 2997-001:2017
EN 2997-001:2017 (E) 15 Table 3 — Mating dimensions for plugs Housing size Thread Class 2B a
ØB max. ØH min. ØJ ØK min. 08 0.5625 - 24 UNEF 7,37 7,47 10,29 10,16 14,61 10 0.6875 - 24 UNEF 10,37 10,87 13,36 13,23 17,96 12 0.8750 - 20 UNEF 14,69 15,19 17,68 17,55 22,73 14 0.9375 - 20 UNEF 16,44 16,94 19,43 19,30 24,31 16 1.0625 - 18 UNEF 19,67 20,17 22,66 22,53 27,53 18 1.1875 - 18 UNEF 22,36 22,86 25,35 25,22 30,71 20 1.3125 - 18 UNEF 25,54 26,04 28,52 28,40 33,88 22 1.4375 - 18 UNEF 28,71 29,21 31,70 31,57 37,06 24 1.5625 - 18 UNEF 31,88 32,38 34,87 34,75 40,23 28 1.8125 - 16 UN 38,23 38,73 41,22 41,09 46,58 a ISO 263.
6.4 Receptacle and plug polarization See Figure 5 and Tables 4 and 5. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 16 Dimensions and tolerances are in millimetres.
Key 1 Keyway for main key 2 Four secondary keyways 3 Main key 4 Four secondary keys a
Five keyways b
Five keys Figure 5 — Receptacle and plug SIST EN 2997-001:2017
EN 2997-001:2017 (E) 17 Table 4 — Position of the keys and keyways
Housing sizes - Values in degrees Position 08 10 12 to 28
A B C D A B C D A B C D N 105 140 215 265 105 140 215 265 105 140 215 265 6 102 132 248 320 102 132 248 320 18 149 192 259 7 80 118 230 312 80 118 230 312 92 152 222 342 8 35 140 205 275 35 140 205 275 84 152 204 334 9 64 155 234 304 64 155 234 304 24 135 199 240 Y – – – – 25 115 220 270 98 152 268 338
Table 5 — Dimensions of the keys and keyways Housing size G H J L M N 08 2,21 2,05 1,40 1,24 5,72 5,64 2,47 2,31 1,96 1,83 5,92 5,79 10 7,24 7,16 7,45 7,32 12 9,40 9,32 9,60 9,47 14 10,29 10,21 10,49 10,36 16 3,00 2,84 11,89 11,81 3,26 3,10 12,09 11,96 18 13,23 13,15 13,44 13,31 20 14,81 14,73 15,01 14,58 22 16,41 16,33 16,61 16,48 24 17,98 17,90 18,19 18,06 28 21,16 21,08 21,42 21,29
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 18 6.5 Dimensions of the rear interface 6.5.1 Dimensions of the rear accessory interface The rear dimensions of receptacles and plugs with threads for mounting cable outlet accessories are shown in Figure 6 and in Table 7. Accessory teeth shall be aligned with the centre line of the main key/keyway as shown in Figure 4 within the tolerances shown in Table 6. Table 6 — Tolerances of alignment Housing size Alignment tolerance of axis 8 to 12 ± 3° 14 to 18 r 2° 20 and greater r 1°
Dimensions are in millimetres.
Key 1 Grommet 2 Thread 3 Master key 4 Crest of tooth Figure 6 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 19 Table 7 — Dimensions of rear interface Housing size ØA max. ØB min. ØC max. Thread class 2A a ØE max. N Number of teeth 08 7,75 9,40 11,10 0.500 - 20 UNF 12,70 12 10 10,29 12,62 14,53 0.6250 - 24 UNEF 15,88 15 12 13,49 15,57 17,45 0.7500 - 20 UNEF 19,05 21 14 16,89 18,75 20,62 0.8750 - 20 UNEF 22,23 24 16 20,07 21,92 23,80 1.0000 - 20 UNEF 25,40 30 18 22,07 23,34 25,20 1.0625 -18 UNEF 26,97 33 20 25,25 26,52 28,37 1.1875 - 18 UNEF 30,18 36 22 28,42 29,69 31,55 1.3125 - 18 UNEF 33,32 39 24 31,60 32,87 34,72 1.4375 - 18 UNEF 36,53 42 28 37,90 39,22 42,67 1.7500 - 18 UN 44,45 54 a ISO 263.
6.5.2 Dimensions of the rear cable entry (Integrated cable outlet) Dimensions of rear cable entry for shield termination with band according to EN 3660-033, and accommodation for heat shrinkable accessory. See Figures 7 to 9 and Table 8. SIST EN 2997-001:2017
EN 2997-001:2017 (E) 20
Key 1 0,13 REF. min. step (ØZG) to coupling nut rear face 2 Diamond knurl male or female (see below), pitch of 0,1 mm, width 10,5 mm min. 3 Straight knurl (see below), pitch of 1 mm, width 3 mm min.
Straight Diamond Figure 7 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 21
Connector side Wiring side Key 1 Applicable to plug and receptacle. Except housing size 8: 1,5 max.
2 3 mm min. flat 3 Applicable to plug and receptacle 4 Applicable to receptacle Figure 8 — Detail A
Key 1 Both ends of ØG 2 No sharp edge Figure 9 — Detail B
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 22 Table 8 — Dimensions for models A, B, C and D Housing size
ØG ØH ØJ ØL ØM ØY ØZG ØZJ ± 0,10 min. ± 0,10 ± 0,10 ± 0,10 max. ± 0,25 max. 8 11,70 9,40 17,10 12,10 18,70 14,27 19,50 7,75 10 14,92 12,62 18,00 15,32 19,60 17,68 21,50 10,29 12 17,87 15,57 20,40 18,27 22,00 22,22 23,50 13,49 14 21,05 18,75 24,50 21,45 26,10 23,78 28,00 16,89 16 24,22 21,92 27,00 24,62 28,60 26,97 30,50 20,07 18 25,64 23,34 28,20 26,04 29,80 30,15 31,70 22,07 20 28,82 26,52 32,00 29,22 33,60 33,32 35,50 25,25 22 32,00 29,69 35,10 32,40 36,70 36,50 38,60 28,42 24 35,17 32,87 40,50 35,57 42,10 39,67 42,00 31,60 28 41,52 39,22 45,00 41,92 46,60 46,02 48,50 37,90
6.6 Contact arrangements The contact arrangements in the inserts are specified by Figures 10 to 44, which show the front face of the female inserts. The following tolerances apply to the inserts fitted in the housings (A and B reference Figure 5): • centre of each hole: ∅ 0,36 A B
• centre of each contact end: ∅ 0,61 A B
Identification of the contact position shall be permanently applied in contrasting colour on the front face of the insert or interfacial seal and on the rear face of the wire sealing grommet. Identification shall not be recessed or raised on the sealing surfaces. Symbols for contact sizes are given in EN 3155-001. Housing sizes and contact arrangements (see Figures 10 to 44).
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 23 08-03 3 contacts size 20
08-06 6 contacts size 22
08-98 3 contacts size 20
Contact X mm Y mm
Contact X mm Y mm
Contact X mm Y mm 1 0 + 1,91
1 0 0
1 − 1,65
0,94 2 − 1,65
0,97
2 − 2,40
0,78
2 0 − 1,91 3 + 1,65
0,97
3 − 1,48
2,04
3 + 1,65
0,94
4 + 1,48
2,04
5 + 2,40
0,78
6 0 + 2,53
Figure 10
Figure 11
Figure 12
10-02 2 contacts size 20
10-05 5 contacts size 20
10-06 6 contacts size 20
Contact X mm Y mm
Contact X mm Y mm
Contact X mm Y mm 1 0 + 2,11
1 − 2,72
1,04
1 0 0 2 0 − 2,11
2 − 1,88
2,16
2 − 3,05
1,27
3 + 1,88
2,16
3 − 1,65
2,87
4 + 2,72
1,04
4 + 1,65
2,87
5 0 + 2,90
5 + 3,05
1,27
6 0 + 3,30 Figure 13
Figure 14
Figure 15
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 24 10-12 12 contacts size 22
12-03 3 contacts size 16
Contact X mm Y mm Contact X mm Y mm
Contact X mm Y mm 1 0 + 1,46 7 − 3,34
1,93
1 0 + 3,05 2 − 1,26
0,73 8 − 3,8
0,67
2 − 2,64
1,52 3 + 1,26
0,73 9 − 2,48
2,95
3 + 2,64
1,52 4 + 3,34
1,93 10 0 − 3,86
5 + 1,32
3,62 11 + 2,48
2,95
6 − 1,32
3,62 12 + 3,8
0,67
Figure 16
Figure 17 12-12 12 contacts size 20
12-21 21 contacts size 22
Contact X mm Y mm
Contact X mm Y mm Contact X mm Y mm 1 0 + 1,88
1 0 0 12 − 5,44 − 0,66 2 − 1,65 − 0,99
2 − 2,31 + 1,84 13 − 4,51 − 3,11 3 + 1,65
0,99
3 − 2,88
0,66 14 − 2,54
4,85 4
4,24
2,67
4
1,28
2,66 15 0
5,48 5
1,65
4,75
5
1,28
2,66 16
2,54
4,85 6
1,65
4,75
6
2,88
0,66 17
4,51
3,11 7
4,24
2,67
7
2,31
1,84 18
5,44
0,66 8 − 4,95
0,84
8 0 + 2,95 19 + 5,12
1,94 9
3,15
3,91
9
1,31
5,32 20
3,63
4,10 10 0
5,00
10
3,63
4,10 21
1,31
5,32 11
3,15
3,91
11
5,12
1,94 — 12
4,95
0,84
Figure 18
Figure 19 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 25 14-04 4 contacts size 12
14-07 7 contacts size 16
Contact X mm Y mm
Contact X mm Y mm 1 − 4,29 0
1 0 0 2 0 − 4,29
2 − 2,41
4,17 3 + 4,29 0
3 − 4,83 0 4 0
4,29
4
2,41
4,17
5 + 2,41
4,17
6 + 4,83 0
7
2,41
4,17 Figure 20
Figure 21
14-12 9 contacts size 20 3 contacts size 16
Contact X mm Y mm Contact X mm Y mm 1 0 + 2,29 7 − 4,45
2,57 2
1,98
1,14 8
5,69
1,37 3 + 1,98
1,14 9 − 4,04
4,24 4 + 4,45
2,57 10 0 − 5,13 5
1,65
5,61 11
4,04
4,24 6 − 1,65
5,61 12 + 5,69
1,37 Figure 22 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 26 14-15 15 contacts size 20
16-10 10 contacts size 16
Contact X mm Y mm Contact X mm Y mm
Contact X mm Y mm 1 − 2,34 0 9 − 4,42
3,84
1 0 − 2,67 2 0 − 2,44 10 − 1,65
5,61
2 0 + 2,16 3 + 2,34 0 11 + 1,65
5,61
3 − 6,02
3,15 4 0 + 2,44 12 + 4,42
3,84
4 − 6,58
1,65 5 0 + 5,87 13 + 5,79
0,83
5 − 3,81
5,64 6 − 3,18
4,93 14 + 5,33
2,44
6 + 3,81
5,64 7 − 5,33
2,44 15 + 3,18
4,93
7 + 6,58
1,65 8 − 5,79
0,83
8 + 6,02
3,15
9 + 2,41
6,38
10 − 2,41
6,38 Figure 23
Figure 24 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 27 16-24 24 contacts size 20
Contact X mm Y mm Contact X mm Y mm Contact X mm Y mm 1 0 + 1,91 9 − 4,50
2,59 17 − 2,84
6,83 2 − 1,65
0,94 10 − 1,65
4,24 18 − 5,69
5,18 3 + 1,65
0,94 11 + 1,65
4,24 19 − 7,34
2,36 4 + 4,50
0,71 12 + 4,50
2,59 20 − 7,34
0,94 5 + 2,84
3,56 13 + 7,34
0,94 21 − 4,50
5,89 6 0 + 5,18 14 + 7,34
2,36 22 − 1,65
7,54 7 − 2,84
3,56 15 + 5,69
5,18 23 + 1,65
7,54 8 − 4,50
0,71 16 + 2,84
6,83 24 + 4,50
5,89 Figure 25
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 28 18-08 8 contacts size 12
Contact X mm Y mm 1 0 0 2 − 5,56
4,45 3 − 6,93
1,57 4 − 3,07
6,40 5 + 3,07
6,40 6 + 6,93
1,57 7 + 5,56
4,45 8 0 + 7,11 Figure 26 SIST EN 2997-001:2017
EN 2997-001:2017 (E) 29 18-14 14 contacts size 16
Contact X mm Y mm Contact X mm Y mm 1 − 3,30 0 8 − 6,71
4,62 2 0 − 3,58 9 − 2,87
7,62 3 + 3,30 0 10 + 2,87
7,62 4 0 + 3,58 11 + 6,71
4,62 5 − 2,87
7,62 12 + 8,15 0 6 − 6,71
4,62 13 + 6,71
4,62 7 − 8,15 0 14 + 2,87
7,62 Figure 27
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 30 18-31 31 contacts size 20
20-16 16 contacts size 16
Contact X mm Y mm Contact X mm Y mm
Contact X mm Y mm 1 0 0 17 + 6,60 0
1 − 3,91
1,57 2 − 1,65
2,87 18 + 4,95
2,87
2 − 2,39
3,10 3 − 3,30 0 19 + 3,30
5,74
3 + 2,39
3,10 4 − 1,65
2,87 20 + 1,65
8,61
4 + 3,91
1,57 5 + 1,65
2,87 21 − 1,65
8,61
5 0 + 4,45 6 + 3,30 0 22 − 6,60
5,74
6 − 3,00
8,18 7 + 1,65
2,87 23 − 8,26
2,87
7 − 6,88
5,36 8 0 + 5,74 24 − 8,26
2,87
8 − 8,66
0,91 9 − 3,30
5,74 25 − 6,60
5,74
9 − 7,82
3,81 10 − 4,95
2,87 26 − 1,65
8,61
10 − 4,62
7,37 11 − 6,60 0 27 + 1,65
8,61
11 0 − 8,71 12 − 4,95
2,87 28 + 6,60
5,74
12 + 4,62
7,37 13 − 3,30
5,74 29 + 8,26
2,87
13 + 7,82
3,81 14 0 − 5,74 30 + 8,26
2,87
14 + 8,66
0,91 15 + 3,30
5,74 31 + 6,60
5,74
15 + 6,88
5,36 16 + 4,95
2,87
16 + 3,00
8,18 Figure 28
Figure 29
SIST EN 2997-001:2017
EN 2997-001:2017 (E) 31 20-25 19 contacts size 20 6 conta
...