SIST EN 61558-2-9:2011
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-9: Particular requirements and tests for transformers and power supply units for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2010)
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-9: Particular requirements and tests for transformers and power supply units for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2010)
Replacement:
This part of IEC 61558 deals with the safety of transformers for class III handlamps for tungsten filament lamps and power supply units incorporating transformers for class III handlamps for tungsten filament lamps. Transformers incorporating electronic circuits are also covered by this standard.
NOTE 1 Safety includes electrical, thermal, mechanical and chemical aspects.
Unless otherwise specified, from here onward, the term transformer covers transformers for
class III handlamps for tungsten filament lamps and power supply units incorporating transformers for class III handlamps for tungsten filament lamps. This part is applicable to stationary or portable single-phase air-cooled (natural or forced) independent or associated dry-type transformers. The windings may be encapsulated or non-encapsulated. This standard is applicable to transformers and power supply (linear) with internal operational frequencies not exceeding 500 Hz. This standard used in combination with Part 2-16 for switch mode power supply (SMPS) units is also applicable to power supplies with internal operational frequencies higher than 500 Hz. Where the two requirements are in conflict, the most severe take precedence. The rated supply voltage does not exceed 1 000 V a.c., and the rated supply frequency and the internal operational frequencies do not exceed 500 Hz. Transformers for class III handlamps for tungsten filament lamps have the following additional characteristics:
– the no-load output voltage and the rated output voltage do not exceed 50 V a.c. or 120 V ripple-free d.c.;
– there is only a small difference between the no-load voltage and the rated output voltage.
The rated output does not exceed:
– 10 kVA.
This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard.
NOTE 2 Attention is drawn to the following:
- for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary;
- measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered;
- the different conditions for transportation, storage, and operation of the transformers should also be considered;
- additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments.
NOTE 3 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies, until then this part may be used as a guidance document.
Sicherheit von Transformatoren, Drosseln, Netzgeräten und entsprechende Kombinationen - Teil 2-9: Besondere Anforderungen und Prüfungen an Transformatoren und Netzgeräten für Handleuchten der Schutzklasse III mit Wolframdrahtlampen (IEC 61558-2-9:2010)
Sécurité des transformateurs, bobines d’inductance, blocs d'alimentation et des combinaisons de ces éléments - Partie 2-9: Règles particulières et essais pour les transformateurs et blocs d'alimentation pour lampes baladeuses de classe III à filament de tungstène (CEI 61558-2-9:2010)
La CEI 61558-2-9:2010 traite de la sécurité des transformateurs pour lampes baladeuses de classe III pour lampes à filament de tungstène et blocs d'alimentation incorporant des transformateurs pour lampes baladeuses de classe III pour lampes à filament de tungstène. Les transformateurs incorporant des circuits électroniques sont également couverts par la présente norme. Cette deuxième édition annule et remplace la première édition publiée en 2002. Elle constitue une révision technique. Les principales modifications comprennent la mise à jour de la présente partie conformément à la CEI 61558-1:2005, et l'ajout des blocs d'alimentation au domaine d'application. La présente partie a le statut de publication groupée de sécurité conformément au Guide CEI 104. L'attention des Comités Nationaux est attirée sur le fait que les fabricants d'appareils et les organismes d'essai peuvent avoir besoin d'une période transitoire après la publication d'une nouvelle publication CEI, ou d'une publication amendée ou révisée, pour fabriquer des produits conformes aux nouvelles exigences et pour adapter leurs équipements aux nouveaux essais ou aux essais révisés. Le comité recommande que le contenu de cette publication soit entériné au niveau national au plus tôt 12 mois après la date de publication.
Varnost transformatorjev, dušilk, napajalnikov in podobnih proizvodov - 2-9. del: Posebne zahteve in preskusi za transformatorje in napajalnike za ročne svetilke razreda III z volframovo nitko (IEC 61558-2-9:2010)
Nadomestilo:
Ta del IEC 61558 obravnava varnost transformatorjev za ročne svetilke razreda III z volframovo nitko in napajalnike, ki vsebujejo transformatorje za svetilke razreda III z volframovo nitko. Transformatorji, ki vsebujejo elektronska vezja, so prav tako zajeti v tem standardu.
OPOMBA 1: Varnost vključuje električne, toplotne, mehanske in kemične vidike.
Razen če je drugače določeno, od tu naprej pojem transformator zajema transformatorje za:
ročne svetilke razreda III z volframovo nitko in napajalnike, ki vsebujejo transformatorje za ročne svetilke razreda III z volframovo nitko. Ta del se uporablja za nepremične ali prenosne, enofazne, zračno hlajene (naravno ali vsiljeno), samostojne ali povezane transformatorje suhega tipa. Navitje je lahko inkapsulirano ali nekapsulirano. Ta standard se uporablja za transformatorje in napajalnike (linearne) z notranjimi obratovalnimi frekvencami, ki ne presegajo 500 Hz. Ta standard, v kombinaciji z delom 2–16 za stikalne napajalnike (SMPS), se uporablja tudi za napajalnike z notranjimi obratovalnimi frekvencami, višjimi od 500 Hz. Kjer sta zahtevi v nasprotju, ima prednost najstrožja. Ocenjena napetost napajanja ne presega 1.000 V izmeničnega toka, nazivna frekvenca napajanja in notranja obratovalna frekvenca pa ne presegata 500 Hz. Transformatorji za ročne svetilke razreda III z volframovo nitko imajo naslednje dodatne značilnosti:
– neobremenjena izhodna napetost in ocenjena izhodna napetost ne presegate 50 V izmeničnega toka ali 120 V enosmernega toka brez nihanja,
– razlika med neobremenjeno napetostjo in ocenjeno izhodno napetostjo je majhna.
Ocenjena izhodna moč ne presega:
– 10 kVA.
Ta del ne velja za zunanje tokokroge in njihove komponente, ki so namenjene povezavi z vhodnimi terminali in izhodnimi terminali transformatorjev. Transformatorji, ki jih zajema ta del, se uporabljajo v napravah, kjer dvojno ali okrepljeno izolacijo med krogotoki zahtevajo pravila inštalacije ali standard za končni proizvod.
OPOMBA 2: Upoštevati je treba naslednje:
– za transformatorje, namenjene uporabi v vozilih, na krovih ladij in zračnih plovil, so lahko potrebne dodatne zahteve (iz drugih standardov, ki veljajo, državna pravila itd.),
– meritve za zaščito ohišij in komponent v ohišjih pred zunanjimi vplivi, kot so plesen, mrčes, termiti, sončevo sevanje in led, je prav tako treba upoštevati,
– različne pogoje za transport, hranjenje in delovanje transformatorjev je prav tako treba upoštevati,
– dodatne zahteve v skladu z drugimi primernimi standardi in državnimi pravili, lahko veljajo za transformatorje, namenjene uporabi v posebnih okoljih.
OPOMBA 3: Prihodnji tehnološki razvoj transformatorjev lahko zahteva potrebo po dvigu zgornje meje frekvenc, do takrat se lahko ta del uporablja kot dokument s smernicami.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61558-2-9:2011
01-april-2011
1DGRPHãþD
SIST EN 61558-2-9:2003
9DUQRVWWUDQVIRUPDWRUMHYGXãLONQDSDMDOQLNRYLQSRGREQLKSURL]YRGRYGHO
3RVHEQH]DKWHYHLQSUHVNXVL]DWUDQVIRUPDWRUMHLQQDSDMDOQLNH]DURþQHVYHWLONH
UD]UHGD,,,]YROIUDPRYRQLWNR,(&
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-9:
Particular requirements and tests for transformers and power supply units for class III
handlamps for tungsten filament lamps (IEC 61558-2-9:2010)
Sicherheit von Transformatoren, Drosseln, Netzgeräten und entsprechende
Kombinationen - Teil 2-9: Besondere Anforderungen und Prüfungen an Transformatoren
und Netzgeräten für Handleuchten der Schutzklasse III mit Wolframdrahtlampen (IEC
61558-2-9:2010)
Sécurité des transformateurs, bobines d’inductance, blocs d'alimentation et des
combinaisons de ces éléments - Partie 2-9: Règles particulières et essais pour les
transformateurs et blocs d'alimentation pour lampes baladeuses de classe III à filament
de tungstène (CEI 61558-2-9:2010)
Ta slovenski standard je istoveten z: EN 61558-2-9:2011
ICS:
29.180 Transformatorji. Dušilke Transformers. Reactors
SIST EN 61558-2-9:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61558-2-9:2011
---------------------- Page: 2 ----------------------
SIST EN 61558-2-9:2011
EUROPEAN STANDARD
EN 61558-2-9
NORME EUROPÉENNE
February 2011
EUROPÄISCHE NORM
ICS 29.180 Supersedes EN 61558-2-9:2003
English version
Safety of transformers, reactors, power supply units and combinations
thereof -
Part 2-9: Particular requirements and tests for transformers and power
supply units for class III handlamps for tungsten filament lamps
(IEC 61558-2-9:2010)
Sécurité des transformateurs, bobines Sicherheit von Transformatoren, Drosseln,
d’inductance, blocs d'alimentation et des Netzgeräten und entsprechende
combinaisons de ces éléments - Kombinationen -
Partie 2-9: Règles particulières et essais Teil 2-9: Besondere Anforderungen und
pour les transformateurs et blocs Prüfungen an Transformatoren und
d'alimentation pour lampes baladeuses de Netzgeräten für Handleuchten der
classe III à filament de tungstène Schutzklasse III mit Wolframdrahtlampen
(CEI 61558-2-9:2010) (IEC 61558-2-9:2010)
This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61558-2-9:2011 E
---------------------- Page: 3 ----------------------
SIST EN 61558-2-9:2011
EN 61558-2-9:2011 - 2 -
Foreword
The text of document 96/355/FDIS, future edition 2 of IEC 61558-2-9, prepared by IEC TC 96,
Transformers, reactors, power supply units, and combinations thereof, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61558-2-9 on 2011-01-02.
This European Standard supersedes EN 61558-2-9:2003.
The main changes consist of updating this part in accordance with EN 61558-1:2005, and adding power
supply units to the scope.
This part has the status of a group safety publication in accordance with IEC Guide 104:1997, The
preparation of safety publications and the use of basic safety publications and group safety publications.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-10-02
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-02
This part is intended to be used in conjunction with the latest edition of EN 61558-1 and its amendments.
It is based on EN 61558-1:2005.
This part supplements or modifies the corresponding clauses in EN 61558-1, so as to convert that
publication into the European standard: Particular requirements and tests for transformers and power
supply units for class III handlamps for tungsten filament lamps.
Where a particular subclause of Part 1 is not mentioned in this part, that subclause applies as far as is
reasonable. Where this part states "addition", "modification" or "replacement", the relevant text of Part 1 is
to be adopted accordingly.
In this part, the following print types are used:
– requirements proper: in roman type;
– test specifications: in italic type;
– explanatory matters: in smaller roman type.
In the text of this part, the words in bold are defined in Clause 3.
Subclauses additional to those in Part 1 are numbered starting from 101; supplementary annexes are
entitled AA, BB, etc.
Annex ZA has been added by CENELEC.
__________
---------------------- Page: 4 ----------------------
SIST EN 61558-2-9:2011
- 3 - EN 61558-2-9:2011
Endorsement notice
The text of the International Standard IEC 61558-2-9:2010 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61558-2-16:2009 NOTE Harmonized as EN 61558-2-16:2009 (not modified).
__________
---------------------- Page: 5 ----------------------
SIST EN 61558-2-9:2011
EN 61558-2-9:2011 - 4 -
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Annex ZA of Part 1 is applicable except as follows:
Addition:
Publication Year Title EN/HD Year
IEC 61558-1 2005 Safety of power transformers, power supplies, EN 61558-1 2005
reactors and similar products - + corr. August 2006
Part 1: General requirements and tests
---------------------- Page: 6 ----------------------
SIST EN 61558-2-9:2011
IEC 61558-2-9
®
Edition 2.0 2010-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
GROUP SAFETY PUBLICATION
PUBLICATION GROUPÉE DE SÉCURITÉ
Safety of transformers, reactors, power supply units and combinations thereof –
Part 2-9: Particular requirements and tests for transformers and power supply
units for class III handlamps for tungsten filament lamps
Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et des
combinaisons de ces éléments –
Partie 2-9: Règles particulières et essais pour les transformateurs et blocs
d’alimentation pour lampes baladeuses de classe III à filament de tungstène
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
M
CODE PRIX
ICS 29.180 ISBN 978-2-88912-037-6
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 61558-2-9:2011
– 2 – 61558-2-9 © IEC:2010
CONTENTS
FOREWORD.3
1 Scope.5
2 Normative references .6
3 Terms and definitions .6
4 General requirements .6
5 General notes on tests .6
6 Ratings.6
7 Classification.7
8 Marking and other information .7
9 Protection against electric shock .7
10 Change of input voltage setting .8
11 Output voltage and output current under load .8
12 No-load output voltage .8
13 Short-circuit voltage .9
14 Heating .9
15 Short-circuit and overload protection .9
16 Mechanical strength .9
17 Protection against harmful ingress of dust, solid objects and moisture.9
18 Insulation resistance, dielectric strength and leakage current .9
19 Construction .9
20 Components .11
21 Internal wiring.11
22 Supply connection and other external flexible cable or cords .11
23 Terminals for external conductors.11
24 Provisions for protective earthing .12
25 Screws and connections .12
26 Creepage distances, clearances and distances through insulation.12
27 Resistance to heat, fire and tracking.12
28 Resistance to rusting.12
Annexes .13
Bibliography.13
Table 101 – Ratio of output voltages for transformers for class III tungsten filament
handlamps .8
---------------------- Page: 8 ----------------------
SIST EN 61558-2-9:2011
61558-2-9 © IEC:2010 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SAFETY OF TRANSFORMERS, REACTORS,
POWER SUPPLY UNITS AND COMBINATIONS THEREOF –
Part 2-9: Particular requirements and tests for transformers and
power supply units for class III handlamps for tungsten filament lamps
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International standard IEC 61558-2-9 has been prepared by IEC technical committee 96:
Transformers, reactors, power supply units and combinations thereof.
This second edition cancels and replaces the first edition published in 2002. It constitutes a
technical revision. The main changes consist of updating this part in accordance with
IEC 61558-1:2005, and adding power supply units to the scope.
This part has the status of a group safety publication in accordance with IEC Guide 104:
1997, The preparation of safety publications and the use of basic safety publications and
group safety publications.
---------------------- Page: 9 ----------------------
SIST EN 61558-2-9:2011
– 4 – 61558-2-9 © IEC:2010
The text of this standard is based on the following documents:
FDIS Report on voting
96/355/FDIS 96/362/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This part is intended to be used in conjunction with the latest edition of IEC 61558-1 and its
amendments. It is based on the second edition (2005) of that standard.
This part supplements or modifies the corresponding clauses in IEC 61558-1, so as to convert
that publication into the IEC standard: Particular requirements and tests for transformers and
power supply units for class III handlamps for tungsten filament lamps.
A list of all parts of the IEC 61558 series, under the general title: Safety of transformers,
reactors, power supply units and combinations thereof, can be found on the IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
Where a particular subclause of Part 1 is not mentioned in this part, that subclause applies as
far as is reasonable. Where this part states "addition", "modification" or "replacement", the
relevant text of Part 1 is to be adopted accordingly.
In this part, the following print types are used:
– requirements proper: in roman type;
– test specifications: in italic type;
– explanatory
...