Integrated Services Digital Network (ISDN); Basic user-network interface; Layer 1 specification and test principles

System conformance statements (SCS), PICS & PIXIT complementary to ETS 300 012. Both interface sides (ie interface points 1a & 1b) are covered.

Digitalno omrežje z integriranimi storitvami (ISDN) – Osnovni vmesnik uporabnik-omrežje – Specifikacija prve plasti in načela preskušanja

General Information

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Standard

Amendment
ETS 300 012/A2 E1:2003
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ETS 300 012/A2 E1:2003
01-december-2003
'LJLWDOQRRPUHåMH]LQWHJULUDQLPLVWRULWYDPL ,6'1 ±2VQRYQLYPHVQLNXSRUDEQLN
RPUHåMH±6SHFLILNDFLMDSUYHSODVWLLQQDþHODSUHVNXãDQMD
Integrated Services Digital Network (ISDN); Basic user-network interface; Layer 1
specification and test principles
Ta slovenski standard je istoveten z: ETS 300 012/A2 Edition 1
ICS:
33.080 Digitalno omrežje z Integrated Services Digital
integriranimi storitvami Network (ISDN)
(ISDN)
SIST ETS 300 012/A2 E1:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ETS 300 012/A2 E1:2003

---------------------- Page: 2 ----------------------

SIST ETS 300 012/A2 E1:2003
ETS 300 012
AMENDMENT A2
March 1996
Source: ETSI TC-TM Reference: RE/TM-03016
ICS: 33.080
ISDN, user-network interface, testing
Key words:
This amendment A2 modifies
the European Telecommunication Standard ETS 300 012 (1992)
Integrated Services Digital Network (ISDN);
Basic user-network interface;
Layer 1 specification and test principles
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
*
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1996. All rights reserved.

---------------------- Page: 3 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 2
ETS 300 012: April 1992/A2: March 1996
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 3
ETS 300 012: April 1992/A2: March 1996
Foreword
This amendment to ETS 300 012 (1992) has been produced by the Transmission and Multiplexing (TM)
Technical Committee of the European Telecommunications Standards Institute (ETSI).
This second amendment incorporates the changes introduced by Amendment 1 (1994) to ETS 300 012.
Newly introduced modifications are indicated by a revision bar located at the left margin.
This second amendment adds a new annex F and related references, definitions and abbreviations to
ETS 300 012.
Transposition dates
Date of adoption of this ETS: 22 September 1995
Date of latest announcement of this ETS (doa): 30 June 1996
Date of latest publication or endorsement of this amendment (dop/e): 31 December 1996
Date of withdrawal of any conflicting National Standard (dow): 31 December 1996
Amendments
Page 12, clause 2
Add the following references to the Normative references clause (clause 2):
[17] CCITT Recommendation I.112 (1988): "Vocabulary of terms for ISDNs".
[18] CCITT Recommendation Q.9 (1988): "Vocabulary of switching and signalling
terms".
[19] ISO/IEC 9646-1 (1991): "OSI Conformance Testing Methodology and
Framework Part 1: General Concepts".
[20] ISO/IEC 9646-5 (1991): "OSI Conformance Testing Methodology and
Framework Part 5: Requirements on test laboratories and clients for the
conformance assessment process".
Page 13, clause 3
Add the following definitions to the definitions clause (clause 3):
I
ntegrated Services Digital Network (ISDN): See CCITT Recommendation I.112 [17], § 2.3,
definition 308.
basic access: See CCITT Recommendation Q.9 [18], § 1, definition 1551.
Protocol Implementation Conformance Statement (PICS): See ISO/IEC 9646-1 [19], § 3.4.6.

---------------------- Page: 5 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 4
ETS 300 012: April 1992/A2: March 1996
Page 14, clause 4
Add the following abbreviations to the abbreviations clause (clause 4):
APS Auxiliary Power Source
HDLC High level Data Link Control
IUT Implementation Under Test
PCTR Protocol Conformance Test Report
PICS Protocol Implementation Conformance Statement
PIXIT Protocol Implementation Extra Information for Testing
RSE Remote Single layer Embedded
SCS System Conformance Statement
SCTR System Conformance Test Report
Page 18, figure 3
Replace figure 3 with the following figure:
CL
TE
+
U = 40 V
U
= 24 V
Z
C1
S
C2
IU T
-
CS
U : Zener voltage
Z
Figure 3: Power start up test for TE

---------------------- Page: 6 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 5
ETS 300 012: April 1992/A2: March 1996
Page 22, figure 7
Replace figure 7 with the following figure:
R R
±
c/e
S
S
R ± R
L
L
R
L
R d/f
S
TE
U = 40 V
i =
30 m A
=
R =
6 R 360 m
S
S
R R
S L
=
X =
2
R 2
R
S L
R =
5 R =
L 300 m
L
Figure 7: Test circuit for applied current unbalance
Page 26, table A.1, table entry A.5.3.2
Replace the table entry A.5.3.2 with the following:
A.5.3.2 TEs not powered across the interface
A TE using the automatic assignment
procedure shall implement the
disconnect detector for detection of
power source 1 or 2 to establish the
connection status.>
Page 29, table A.1, table entry A.6.2.6.1
Replace the final paragraph for table entry A.6.2.6.1 with the following:
shall be replaced (four times) by:
"INFO2 or INFO4">

---------------------- Page: 7 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 6
ETS 300 012: April 1992/A2: March 1996
Page 31, table A.1, table entry A.8.5.4
The statement ("St.-ment") for table entry A.8.5.4 shall be changed to "I" (Informative), as follows:
Clause/ Title St.-
subclause ment
A.8.5.4 Pulse unbalance I
replaced by:
Page 46, subclause D.1.4.4
Replace the fourth instance of "N/R" with "D.3.2.2.1.1", producing a table as follows:
Modes Clause/ Test defined in
subclause Clause/subclause
Types of wiring configuration A.4 N/R
Point-to-point configuration A.4.1 N/R
Point-to-multipoint configuration A.4.2 N/R
Polarity Integrity A.4.3 D.3.2.2.1.1
(figure 2/I.430 [2])
Interface Ia A.4.4 N/R
TE associated wiring A.4.5 N/R
Page 50, subclause D.1.4.11
Replace the final instance of "N/R" with "D.5.1.4.1" and add test for annex B, clause B.6, producing a table
as follows:
    Requirements Clause/ Test defined in
subclause Clause/subclause
Test loopbacks defined for the Annex A
basic user-network interface App. I N/R
Additional requirements applicable B.1 to B.5 N/R
to the explicit S reference point B.6 D.5.1.4.2
TE design to minimise power Annex C D.5.1.4.1
disturbance
Page 57, subclause D.3.2.1
Replace the table in subclause D.3.2.1 with the following table (modifying states 9, 16, 22, 40 and 46 and
adding NOTE 9):

---------------------- Page: 8 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 7
ETS 300 012: April 1992/A2: March 1996
Table to subclause D.3.2.1
STATE CURRENT STIMULUS NOTE NEXT INFO COMMENT
NO STATE STATE SENT
1 F1 Power 1 F2 I0 Detection of power
2 F1 T3 expires 2/6 F1 I0 No action
3 F2 Loss of Power F1 I0 Return to inactive state
4 F2 Rx INFO 0 4 F3 I0 Assume deactivated state
5 F2 Rx INFO 2 F6 I3 Synchronised state
6 F2 Rx INFO 4 F7 I3 Activated
7 F2 Rx any signal 3 F2 I0 No action
8 F2 T3 expires 6 F2 I0 No action
9 F3 Loss of Power 9 F1 I0 Return to inactive
10 F3 PH-AR F4 I1 Initiate activation & T3
11 F3 Rx INFO 0 4 F3 I0 No action
12 F3 Rx INFO 2 F6 I3 Synchronised state
13 F3 Rx INFO 4 F7 I3 Activated
14 F3 Rx any signal 3 F3 I0 No action
15 F3 T3 expires 2 F3 I0 No action
16 F4 Loss of Power 9 F1 I0 Return to inactive state
17 F4 Rx INFO 0 4 F4 I1 No action
18 F4 Rx INFO 2 7 F6 I3 Synchronised
19 F4 Rx INFO 4 7 F7 I3 Active
20 F4 Rx any signal 3 F5 I0 Detection of signal
21 F4 T3 Expires 2 F3 I0 Deactivated
22 F5 Loss of Power 9 F1 I0 Return to inactive
23 F5 Rx INFO 0 4 F5 I0 No action
24 F5 Rx INFO 2 F6 I3 Synchronised
25 F5 Rx INFO 4 F7 I3 Activated
26 F5 Rx any signal 3 F5 I0 No action
27 F5 T3 Expires 2 F3 I0 Deactivated
28 F6 Loss of Power 8 F1 I0 Return to inactive
29 F6 Lost Framing F8 I0 Loss of framing signals
30 F6 PH-AR F6 I3 No action
31 F6 Rx INFO 0 4 F3 I0 Deactivated
32 F6 Rx INFO 2 F6 I3 No action
33 F6 Rx INFO 4 F7 I3 Activated
34 F6 T3 Expires 2 F6 I3 Synchronised
35 F7 Loss of Power 8 F1 I0 Return to inactive
36 F7 Lost Framing F8 I0 Loss of framing
37 F7 Rx INFO 0 4/5 F3 I0 Deactivated
38 F7 Rx INFO 2 F6 I3 Synchronised
39 F7 Rx INFO 4 F7 I3 No action
40 F8 Loss of Power 9 F1 I0 Return to inactive
41 F8 PH-AR F8 I0 No action
42 F8 Rx INFO 0 4/5 F3 I0 Deactivation
43 F8 Rx INFO 2 F6 I3 Synchronised
44 F8 Rx INFO 4 F7 I3 Activated
45 F8 Rx any signal 3 F8 I0 No action
46 F8 T3 expires 2 F3 I0 Assume deactivated state
NOTE 1: Because the IUT can be powered in different ways, it is
     useful to test this IUT with the possible power it is able to
     detect (PS1, PS2, local power).
NOTE 2: T3 = Implementation dependent, not to exceed 30 sec.
NOTE 3: "Any signal" is simulated by any bit pattern on which the IUT
     conforming to subclause A.6.3.1.2, ETS 300 012 is not able to
     synchronise.
NOTE 4: For testing purposes INFO 0 is simulated by a sinusoidal
     signal having a voltage of 100 mV peak to peak (with a
     frequency in the range of 2 kHz to 1000 kHz). The TE shall
     react by transmitting INFO 0 within a period time 250 μs to
     25 ms.
NOTE 5: The PH-DI corresponding to the reception of INFO 0 shall be
     delivered to Layer 2 only if Layer 1 does not re-enter an
     active state before the expiration of a timer of which the
     value is in the range of 500 ms to 1 s.
NOTE 6: Applicable only for TEs which are locally powered and able to
     detect PS1 or PS2.
NOTE 7: If INFO 2 of INFO 4 is not recognised within 5 ms after the
     appearance of a signal, TE shall go to F5. The result is to
     be tested 5 ms after generation of the stimulus.
NOTE 8: For TEs which are locally powered and able to detect PS1 or
     PS2, at the event "disappearance of power" in states F6 or
     F7, no state change shall be observed.
NOTE 9: Locally powered TEs with disconnected detector shall not
     assume disconnection and shall not take any action until the
     voltage of the interface has remained below 24 V for at least
     500 ms (refer to subclause 7.1.1).

---------------------- Page: 9 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 8
ETS 300 012: April 1992/A2: March 1996
Page 58, subclause D.3.2.2.1.1
Replace the title of subclause D.3.2.2.1.1 with the following title:
D.3.2.2.1.1 Test A, in state F3 (subclauses A.4.3 and A.6.2.6.1, ETS 300 012)
Page 58, subclause D.3.2.2.1.1
Replace the paragraph "Stimulus:" with the following text:
Stimulus: INFO 2 type frames from the network. This test shall be performed with both
normal and reversed polarity of the interchange circuit (NT to TE direction).
Page 68, subclause D.3.3
Replace the results and notes 3 and 4 with the following:
Results:
STIMULUS RESULTS COMMENTS
a) 1 bad frame INFO 3 No loss of framing
b) 5 bad frames INFO 0 Framing lost
c) 2 good frames INFO 0 Framing not regained
d) 6 good frames (note 3) INFO 3 Framing regained within 5 frames
NOTE 3: Before the test, the TE shall be in state F8. The input shall be applied with "Any
signal". Multiframing is not covered by this test.
Page 73, subclause D.4.2
Replace the first paragraph of subclause D.4.2, with a subclause heading as follows:
D.4.2.1 TE jitter measurement characteristics (test A) (subclause A.8.2.2, ETS 300 012)
Page 84, subclause D.4.5.2, "System state:"
Replace the "System state:" text with the following:
System state: a) Deactivated (state F3), then
b) Synchronised (state F6).
IUT transmitting INFO 3 containing all binary ONEs in both B-channels (idle
channel code)
Page 95, subclause D.5.1.1
Replace the title of subclause D.5.1.1 with the following title:
D.5.1.1 Normal power conditions (subclauses A.9.3.1.1 and A.9.5.1, ETS 300 012)

---------------------- Page: 10 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 9
ETS 300 012: April 1992/A2: March 1996
Page 100, subclause D.5.1.2
Replace the title of subclause D.5.1.2 with the following title:
D.5.1.2 Restricted power conditions (subclauses A.9.3.1.2 and A.9.5.2, ETS 300 012)
Page 109, subclause D.5.1.4.2
Replace the title of subclause D.5.1.4.2 with the following title:
D.5.1.4.2 Current/time limitation for TE when connecting (subclause 7.1.1, clause B.6,
ETS 300 012)
Page 109, subclause D.5.1.4.2, "Stimulus:"
Replace the "Stimulus:" paragraph with the following:
Stimulus: Phantom supply voltage. Restricted mode
U = - 40 V R = 15 Ω
The test setup shall be capable of providing a connection to ground. The
measurement shall be done in both wires connecting the power supply to the
IUT.
Page 124, subclause E.1.4.4
Replace the fourth instance of "N/R" with "E.3.3.2.1", producing a table as follows:
Modes Clause/ Test defined in
subclause Clause/subclause
Types of wiring configuration A.4 N/R
Point-to-point configuration A.4.1 N/R
Point-to-multipoint configuration A.4.2 N/R
Polarity Integrity A.4.3 E.3.3.2.1
(figure 2/I.430 [2])
Interface Ib A.4.4 N/R
NT associated wiring A.4.5 N/R
Page 137, subclause E.3.3.2.1, Test B
Replace the test name "• Test B" with the following:
• Test B (subclause A.4.3)
Page 137, subclause E.3.3.2.1, Test B, "Stimulus:"
Replace the "Stimulus:" paragraph with the following:
Stimulus: INFO 3 from the TE simulator.
This test shall be performed with both normal and reversed polarity of the
interchange circuit (TE to NT direction).

---------------------- Page: 11 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 10
ETS 300 012: April 1992/A2: March 1996
Page 140, subclause E.3.4, "Results:"
Replace the results and remainder of page 140 (bullet points 1 to 5) with the following:
Results:
STIMULUS RESULTS COMMENTS
a) 1 bad frame (see note 3) INFO 4 No loss of framing
b) 5 bad frames (see note 3) INFO 2 Framing lost
c) 2 good frames (see note 4) INFO 2 Framing not regained
d) 6 good frames (see notes 4 and 5) INFO 4 Framing regained within 5 frames
NOTE 3: Before the commencement of the test, the NT shall be in system state G3.
NOTE 4: Before the test, the NT shall not be in system state G3.
NOTE 5: Multiframing procedure is not covered by this test.
Page 160, subclause E.5.1.4.3
Replace the figure for the test configuration with the following figure:
m ains supply
Rx
A
ITEM
TE
V UNDER
U
R
L
SIMULATOR
TEST
Tx

---------------------- Page: 12 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 11
ETS 300 012: April 1992/A2: March 1996
Page 164, subclause E.5.1.7
Replace the figure for the test configuration with the following figure (modifying the value of the initial
load):
m ains supply
Rx
ITEM
TE
UNDER
SIMULATOR
TEST
Tx
50 m A 30 mA
S
2
(n - 1)
x
30 m A
V
S
1
T = 100 ms

---------------------- Page: 13 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 12
ETS 300 012: April 1992/A2: March 1996
Page 173, subclause E.6.1.5
Replace the figure for the test configuration with the following figure (modifying the value of the initial
load):
m ains supply
Rx
ITEM
TE
UNDER
SIMULATOR
TEST
Tx
50 m A 30 mA
S
2
(n - 1)
x
30 m A
V
S
1
T = 100 ms
Page 178, addition of new annex F
Add the following annex F to the end of the document:

---------------------- Page: 14 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 13
ETS 300 012: April 1992/A2: March 1996
Annex F (normative): System Conformance Statement (SCS), Protocol
Implementation Conformance Statement (PICS) and
Protocol Implementation Extra Information for Testing
(PIXIT) for interface points I and I
a b
Notwithstanding the provisions of the copyright clause related to the text of this ETS, ETSI grants that
users of this ETS may freely reproduce the SCS, PICS and PIXIT proforma in this annex so that they can
be used for their intended purposes and may further publish the completed SCS, PICS and PIXIT
proforma.
F.1 SCS proforma for interface point I (TE)
a
F.1.1 Introduction
A client who requests a conformance test shall provide to the test laboratory a System Conformance
Statement (SCS) and a client checklist. The proforma in this clause may be used to present this SCS.
The main purpose of the SCS is to identify the client organization and the test candidate.
The purpose of the client checklist is to provide a record of test-related information.
F.1.2 Proforma structure and content
The proforma consist of the following tables containing pre-printed guide text:
- client organization: for identification of the client organization;
- test candidate: for identification and itemizing of the test candidate;
- test status of the test candidate and testing claims: for indication of the test status of the test
candidate, summarizing of the testing claims, provision of references to associated System
Conformance Test Report (SCTR) and Protocol Conformance Test Report (PCTR), and
specification of the protocols implemented in the test candidate;
- client checklist: for provision of a record of test-related information.

---------------------- Page: 15 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 14
ETS 300 012: April 1992/A2: March 1996
F.1.3 Filling in guidance
The pre-printed guide text in the proforma indicates the kind of information to be filled in by the client.
Table F.1
Client organization
Client name
Street/No.:
Postal code/City:
Country:
Telephone:
Telefax:
Telex:
Teletex:
Client manager
Name:
Location:
Telephone:
Contact person
Name:
Location:
Telephone:
Additional information

---------------------- Page: 16 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 15
ETS 300 012: April 1992/A2: March 1996
Table F.2
Test candidate
Test candidate identification:
Name Model Version Serial number
Configuration (identify/describe separate units (e.g. scanner, keyboard, printer, etc.).

---------------------- Page: 17 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 16
ETS 300 012: April 1992/A2: March 1996
Table F.3
Test status of the test candidate and testing claims
Layer 1 test status and testing claims
Answer by Yes(=Y) or No(=N) according to the claims:
Tested before? (note) Test wanted? PCTR wanted? Log wanted?
NOTE: If "Yes" in the left column "Tested before?", indicate references to existing test documents (if tested at another test
laboratory the existing test documents should be made available to the current test laboratory).
SCTR PCTR
Test candidate reference (short identification):
Layer 1 implementation
Identify layer 1 component
Name Version
Other information (indicate any other information that may itemize the test candidate or the testing claims):

---------------------- Page: 18 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 17
ETS 300 012: April 1992/A2: March 1996
Table F.4
Client checklist
Reference: subclauses/notes of subclause 6.3.1.3 of ISO/IEC 9646-5 [20].
Details may be specified in the appropriate PIXIT(s) and reference(s) to the relevant PIXIT(s) indicated in this checklist.
Ref. a) COMPLIANCE WITH ISO/IEC 9646-5 [20] (list exceptions, if any):
Ref. b) The information (specification of the test candidate, protocols to be tested) is given in tables F.2
and F.3.
Ref. c) The Remote Single layer Embedded (RSE) test method is used implying that the degree of
terminal equipment testability is sufficient.
Ref. d) Test co-ordination procedures (explain the procedures suitable for use with the test candidate, and
which correspond to the RSE test method or indicate references to clauses of manuals etc. giving
such explanations):
Ref. NOTE 1: Physical requirements and other practical information (indicate any physical test requirements
(space, air conditioning etc.) as well as any other information that may be needed/useful):
Ref. NOTE 2: The information on whom to contact during the conformance assessment process is given in
table F.1.

---------------------- Page: 19 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 18
ETS 300 012: April 1992/A2: March 1996
F.2 PICS proforma for interface point I (TE)
a
F.2.1 Introduction
To evaluate conformance of a particular implementation, it is necessary to have a statement of which
capabilities and options have been implemented for a given protocol. Such a statement is called a PICS. A
client who requests a conformance test shall provide to the test laboratory a completed PICS proforma for
each OSI layer to be tested.
This clause defines the PICS proforma applying to the OSI layer 1 (physical layer) of equipment having
interface Ia (see § 4.4 of CCITT Recommendation I.430 [2]) for the connection to the ISDN basic access
at reference points S or S/T (coincident S and T) (see CCITT Recommendation I.411 [1]) and intended to
be installed on customers premises.
NOTE: In addition to the information provided by a PICS, information relating to the
implementation and its testing environment is essential. Such extra information is
called a PIXIT. Generally PIXIT proforma are produced and provided by the test
laboratory.
The PIXIT proforma provided in clause F.3 should be used.
F.2.2 PICS proforma structure and contents
The PICS proforma consist of tables structured as indicated in references ISO/IEC 9646-1 [19] and
ISO/IEC 9646-5 [20].
F.2.3 Pre-printed table contents
The pre-printed contents of the PICS tables provide the following:
- table/item identification, see subclause F.2.4;
- item names or short descriptions;
- references to the standards;
NOTE: For this ETS, references refer to rows of table A.1 of ETS 300 012, unless otherwise
indicated.
- status attributes specifying the status of the items;
- predicates, see "c" below;
- column to be filled in by the client, see subclause F.2.5.
The status attribute in the "Status" column reflects the conformance requirements defined in the
referenced standard as follows:
m (mandatory): the capability is required to be implemented, in conformance with the protocol
specification. When a mandatory capability is not supported, it is a case of non-
conformance, and the client shall give a justification (see subclause F.2.5).
o (optional): the capability may be implemented, and if it is implemented it is required to
conform to the protocol specification.
c (conditional): the requirement on the capability depends on the selection of other optional or
conditional items; the PICS proforma cannot define in advance a definite status
for the capability, it can only indicate that the status depends on the evaluation
of a predicate. The predicates are indicated in the table column "Predicate" or in
the last table row as item notes.
- (dash): not applicable item, i.e. no requirement can be expressed in a given context.

---------------------- Page: 20 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 19
ETS 300 012: April 1992/A2: March 1996
F.2.4 Table/item identification
The PICS table is provided with a table/item identification label pre-printed to the left in the table headers.
The labels are composed as follows:
- one capital letter, being the first letter of the layer name;
- a serial number.
Each item in a PICS table is provided with a serial number in the left-hand table column, called "Item No."
To identify an item unambiguously, the table label and the item number are combined by use of a slash
character, "/", e.g. in the 2nd table of the Physical layer PICS, the 3rd item is identified by "P2/3".
F.2.5 Filling in guidance
The filling in is done in the rows of right table column named "Support" as follows:
- for implemented items one of: Y, y, Yes, yes or YES is entered;
- for not implemented items one of: N, n, No, no or NO is entered.
For each not implemented mandatory item, the client shall give a justification, e.g. as an added note
associated with the item.

---------------------- Page: 21 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 20
ETS 300 012: April 1992/A2: March 1996
Table F.5
P1 Optional capabilities
Item Item Reference Status Predicate Support
No. ETS 300 012
TE can be connected at reference point S or S/T by means of: A.4.3, A.4.5,
subclause D.1.1
1 o.1 -
- a hard wired cord ≤ 10 m with a plug;
2 - a jack with a cord ≤ 10 m with a plug at each end; o.1.2 -
3 - a "standard ISDN basic access TE cord" ≤ 7 m; A.8.9 o.1.3 -
4 - a "standard ISDN basic access TE o.3 -
cord" > 7 ≤ 10 m;
5 - direct wiring (without a detachable cord). o.1.3 -
TE is powered across the interface and able to use: A.9.1, A.9.1.2,
6 - power source 1 (PS1), normal power conditions; A.9.2.1 o -
7 - power source 1 (PS1), restricted power conditions; o -
8 - power source 2 (PS2), normal power conditions; A.9.3.2 o -
9 - power source 2 (PS2), restricted power conditions. o -
TE is locally powered and: A.5.3.2, A.9.1.2
10 - able to detect PS1 or PS2; o -
11 - unable to detect PS1 or PS2. o -
TE activation/deactivation and connection status are based on: A.5.1.8 & 9,
A.5.3.1 & 2,
A.6.2.3.1 & 2
12 - detection of PS1 or PS2; c P1/6 or P1/8
or P1/10
13 - presence/absence of local power. c P1/10
TE priority class is: A.6.1.4
14 - fixed; c not P1/15
15 - under control of layer 2. c not P1/14
16 TE cannot initiate activation ("answering only terminal"). A.6.2.2 o -
17 TE supports multiframing A.6.3.3 o -
TE minimises power disturbance according to: subclause 7.1.1,
st
18 -1 alternative of annex C of ETS 300 012; annex C, o -
figures C.1, C.2
nd
19 -2 alternative of annex C of ETS 300 012. figure C.4 o -
20 TE is able to switch over from normal to restricted power mode. subclause 7.1.3.3 c P1/6 and
P1/7
o.1 The TE shall meet the requirements with a cord having a minimum length of 5 metres.
o.2 Testing is performed by use of the cord being a part of the TE as well as by use of the reference cord specified in
subclause D.1.1 of annex D.
o.3 Testing is performed by use of the reference cord specified in subclause D.1.1 of annex D.
Table F.6
P2 Major functional characteristics
Item Item Reference Status Support
No. ETS 300 012
1 Two bi-directional 64 kbit/s B-channels are provided. A.5.1.1 m
2 Bit timing takes place at 192 kbit/s. A.5.1.2 m
3 Octet timing takes place at 8 kHz. A.5.1.3 m
4 Frame alignment. A.5.1.4 see table P3
5 One D-channel for each direction is provided at 16 kbit/s. A.5.1.5 m
6 D-channel access. A.5.1.6 see table P4
7 Power transfer across the interface is possible. A.5.1.7 m
8 Deactivation/activation. A.5.1.8, A.5.1.9 see table P5
9 Two interchange circuits, one for each direction, are provided. A.5.2 m
11 Each transmitted frame contains 48 bits for all configurations. A.5.4 m
12 Nominal transmitted bit rate is 192 kbit/s. A.5.4.1 m
13 Binary organisation of the transmitted frame meets the requirements. A.5.4.2 m
14 Contents and grouping of the transmitted frame meet the requirements. A.5.4.2.1 m
15 Relative bit positions meet the requirements. A.5.4.2.3 m
16 Pseudo-ternary line code is used. A.5.5 m
17 TE timing is derived from the NT signals. A.5.6 m

---------------------- Page: 22 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 21
ETS 300 012: April 1992/A2: March 1996
Table F.7
P3 Frame alignment
Item Item Reference Status Support
No. ETS 300 012
1 Frame alignment procedure, based on line code violation, is used. A.6.3 m
2 Frame alignment, on initial activation of TE, meets the requirements. A.6.3.1 m
3 Loss of frame alignment is assumed on the required criterion. A.6.3.1.1 m
4 Frame alignment is assumed to occur on the required criterion. A.6.3.1.2 m
5 Multiframing is handled as required (extra bits are identified, F bits are A.6.3.3 m
A
echoed).
6 Idle code (binary ONE's) is sent in any not-assigned B-channel. A.6.4 m
Table F.8
P4 D-channel access
Item Item Reference Status Predicate Support
No. ETS 300 012
1 Interframe (layer 2) time fill is provided using ONEs. A.6.1.1 m
2 D-echo monitoring is provided. A.6.1.3 m -
3 Collision detection is provided. A.6.1.5 m -
Table F.9
P5 Activation/deactivation
Item Item Reference Status Support
No. ETS 300 012
TE uses the following states as required:
1 - F1 (inactive); A.6.2.1.1.1 m
2 - F2 (sensing); A.6.2.1.1.2 m
3 - F3 (deactivated); A.6.2.1.1.3 m
4 - F4 (awaiting signal); A.6.2.1.1.4 m
5 - F5 (identifying input); A.6.2.1.1.5 m
6 - F6 (synchronized); A.6.2.1.1.6 m
7 - F7 (activated); A.6.2.1.1.7 m
8 - F8 (lost framing). A.6.2.1.1.8 m
9 Activate primitives correspond to the specification. A.6.2.1.3 m
10 Deactivate primitives correspond to the specification. A.6.2.1.4 m
11 Management primitives correspond to the specification. A.6.2.1.5 m
12 Signals INFO 0 and INFO 3 can be sent. A.6.2.2 m
13 Signal INFO 1 can be sent. c.1
14 Signals INFO 0, INFO 2, INFO 4 can be received. m
15 Activation/deactivation procedures meet the requirements. A.6.2.3.1&2 m
16 Timer T3 is < 30 s. A.6.2.5 c.1
17 Activation time in state F3 meets the requirements A.6.2.6.1
(respond to INFO 2/INFO 4 by sending of INFO 3 within 100 ms). m
18 Activation time in state F4 meets the requirements
(cease INFO 1 sending and initiate sending of INFO 0 within 5 ms
and then respond to INFO 2/INFO 4 by sending of INFO 3 within 100 ms). c.1
19 Deactivation time meets the requirements A.6.2.7
(respond to INFO 0 by sending of INFO 0 within 25 ms). m
c.1 Predicate: not P1/16.
Table F.10
P6 Maintenance
Item Item Reference Status Support
No. ETS 300 012
1 Loopback 4 functions are provided. A. Appendix I o

---------------------- Page: 23 ----------------------

SIST ETS 300 012/A2 E1:2003
Page 22
ETS 300 012: April 1992/A2: March 1996
Table F.11
P7 Electrical
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.