Primary batteries -- Part 2: Physical and electrical specifications

Superseded by EN 60086-2:2007

Primärbatterien -- Teil 2: Physikalische und elektrische Spezifikationen

Piles électriques -- Partie 2: Spécifications physiques et électriques

Primarne baterije - 2. del: Fizične in električne specifikacije (standardizacija CR15H270; brisanje BR17345 in PR43; preskusi za uporabo LR6, R6, LR03, R03, LR14, R14, LR20, R20, baterije 6LR61 in 6F22; vrednosti MAD za R1)

General Information

Status
Withdrawn
Publication Date
31-Aug-2004
Withdrawal Date
12-May-2014
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-May-2014
Due Date
05-Jun-2014
Completion Date
13-May-2014

Relations

Buy Standard

Amendment
EN 60086-2:2002/A2:2004
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 60086-2:2002/A2:2004

STANDARD
september 2004
Primarne baterije - 2. del: Fizične in električne specifikacije (standardizacija
CR15H270; brisanje BR17345 in PR43; preskusi za uporabo LR6, R6, LR03,
R03, LR14, R14, LR20, R20, baterije 6LR61 in 6F22; vrednosti MAD za R1)
Primary batteries - Part 2: Physical and electrical specifications (Standardisation of
CR15H270; Deletion of BR17345 and PR43; Applications tests for LR6, R6, LR03,
R03, LR14, R14, LR20, R20, 6LR61 and 6F22 batteries; MAD value for R1)
ICS 29.220.10 Referenčna številka
SIST EN 60086-2:2002/A2:2004(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 60086-2/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM April 2004

ICS 29.220.10


English version


Primary batteries
Part 2: Physical and electrical specifications
(IEC 60086-2:2000/A2:2004)


Piles électriques Primärbatterien
Partie 2: Spécifications physiques Teil 2: Physikalische und elektrische
et électriques Spezifikationen
(CEI 60086-2:2000/A2:2004) (IEC 60086-2:2000/A2:2004)






This amendment A2 modifies the European Standard EN 60086-2:2001; it was approved by CENELEC
on 2004-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this amendment the status of a national standard without any
alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60086-2:2001/A2:2004 E

---------------------- Page: 2 ----------------------

EN 60086-2:2001/A2:2004 - 2 -
Foreword
The text of document 35/1199/FDIS, future amendment 2 to IEC 60086-2:2000, prepared by
IEC TC 35, Primary cells and batteries, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as amendment A2 to EN 60086-2:2001 on 2004-04-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-01-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2007-04-01
__________
Endorsement notice
The text of amendment 2:2004 to the International Standard IEC 60086-2:2000 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________

---------------------- Page: 3 ----------------------

INTERNATIONAL IEC


STANDARD 60086-2


2000



AMENDMENT 2

2004-02

Amendment 2
Primary batteries –
Part 2:
Physical and electrical specifications
 IEC 2004 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale R

International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 4 ----------------------

60086-2 Amend.2  IEC:2004(E)
 – 2 –
FOREWORD
This amendment has been prepared by IEC technical committee 35: Primary cells and
batteries.
The text of this amendment is based on the following documents:
FDIS Report on voting
35/1199/FDIS 35/1203/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2005. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________

This amendment replaces the data corresponding to addition of CR15H270, Figure 5 –
Gauge, and deletion of BR17345 and PR43, and also the data corresponding to R1, LR6,
LR14 and LR20.
Replace pages 9, 11, 12, 13, 14, 15, 16, 17, 20, 21, 24 and 28 by the following new pages
carrying the same numbers.
Insert after page 21, the new page 21bis.
Replace pages 45, 47, 48 and 50 by the following new pages carrying the same numbers.

Global replacement
Replace all footnote “a” references in the remaining unchanged tables from
a

“ Standard conditions.”
with
a

“ Standard conditions (see IEC 60086-1, 6.1, Table 4, Initial discharge test).”

---------------------- Page: 5 ----------------------

– 9 –
60086-2 Amend.2  IEC:2004(E)
b) Category 2: Round batteries
CR14250, CR15H270, CR17345, CR17450
BR17335
c) Category 3: Round batteries according to figure 2 and figure 3
LR9, LR53
CR11108
d) Category 4: Round batteries according to figure 4
PR70, PR41, PR48, PR44
LR41, LR55, LR54, LR43, LR44
SR62, SR63, SR65, SR64, SR60, SR67, SR66, SR58, SR68, SR59, SR69, SR41, SR57,
SR55, SR48, SR56, SR54, SR42, SR43, SR44
CR1025, CR1216, CR1220, CR1616, CR2012, CR1620, CR2016, CR2025, CR2320,
CR2032,CR2330, CR2430, CR2354, CR3032, CR2450
BR1225, BR2016, BR2020, BR2320, BR2325, BR3032
e) Category 5: Other round batteries – Miscellaneous
R40
4LR44
2CR13252
4SR44
5AR40
f) Category 6: Non-round batteries – Miscellaneous
S4
3R12C, 3R12P, 3R12S, 3LR12
4LR61
BR-P2, CR-P2
2CR5
2EP3863
4R25X, 4LR25X
4R25Y
4R25-2, 4LR25-2
6AS4
6AS6
6F22, 6LR61
6F100
6.8 Drawings of round batteries which correspond to figures 1a and 1b, figure 2, figure 3 and
figure 4 are prepared by reduction or enlargement of the relevant original drawings. The other
drawings are prepared by reduction or enlargement of conventional specification drawings.
In each case the drawings show the shape of the relevant batteries. Dimensions for each
battery are shown in the tables.
7 Specification tables and sheets
NOTE See annex C for ease of locating battery sizes.

---------------------- Page: 6 ----------------------

60086-2 Amend.2  IEC:2004(E)
– 11 –

PHYSICAL AND ELECTRICAL SPECIFICATIONS CATEGORY 1 BATTERIES
Dimensions
Discharge conditions
a

Electro-
mm
MAD
Vn
chemical Designation Applications

A B C E F G R
∅ ∅P
V (initial)
system
Daily period
Max. Min. Min. Max. Max. Min. Max. Min. Max. Ω
300 12 h 0,9 76 h Hearing aids
R1
1,5 30,2 29,1 5,0 0,2 4,0 0,5 12,0 10,9 0,5
5,1 5 min 0,9 30 min Portable lighting
b
5,1 0,9 45 min Portable lighting
Personal cassette player
10 1 h 0,9 1,4 h
and tape recorder
R03 1,5 44,5 43,3 4,3 0,5 3,8 0,8 10,5 9,5 0,4 75 4 h 0,9 20 h Radio
15 s per min
24 1,0 4 h Remote control
8 h per day
3,6 c 0,9 120 pulses Pulse test
43 4 h 0,9 25 h Radio
3,9 1 h 0,8 47 min Motor/toy
Personal cassette player
R6C 10 1 h 0,9 3,5 h
(see note)
1,5 50,5 49,2 7,0 0,5 5,5 1,0 14,5 13,5 0,5 and tape recorder
(high capacity)
15 s per min
24 1,0 10,9 h Remote control
8 h per day
c
1,8 0,9 46 pulses Pulse test
43 4 h 0,9 27 h Radio
3,9 1 h 0,8 60 min Motor/toy
Personal cassette player
R6P
10 1 h 0,9 4,1 h
1,5 50,5 49,2 7,0 0,5 5,5 1,0 14,5 13,5 0,5 and tape recorder
(high power)
15 s per min
24 1,0 11 h Remote control
8 h per day
1,8 c 0,9 75 pulses Pulse test
R6S
1,5 50,5 49,2 7,0 0,5 5,5 1,0 14,5 13,5 0,5 43 4 h 0,9 22 h Radio
(standard)
NOTE Delayed discharge performance after 12 months is 80 % of MAD.
a
Standard conditions (see IEC 60086-1, 6.1, Table 4, Initial discharge test).
b
4 min beginning at hourly intervals for 8 h per day.
c
15 s on, 45 s off for 24 h per day.

---------------------- Page: 7 ----------------------

– 12 –
60086-2 Amend.2  IEC:2004(E)


PHYSICAL AND ELECTRICAL SPECIFICATIONS CATEGORY 1 BATTERIES
Dimensions
Discharge conditions
a
Electro- mm
Vn MAD
chemical Designation Applications

A B C E F G R EV
∅ ∅P
V (initial)
system
Daily period
V
Max. Min. Min. Max. Max. Min. Max. Min. Max. Ω
3,9 0,9 250 min Portable lighting
b
6,8 0,9 7 h Tape recorders
1 h
R14C 1,5 50,0 48,6 13,0 0,9 7,5 1,5 26,2 24,9 1,0
(high capacity) 20 0,9 25 h Radio
4 h
3,9 0,8 2,5 h Toy
1 h
3,9 0,9 300 min Portable lighting
b
6,8 0,9 9 h Tape recorders
1 h
R14P 1,5 50,0 48,6 13,0 0,9 7,5 1,5 26,2 24,9 1,0
(high power)
20 0,9 30 h Radio
4 h
3,9 0,8 4,8 h Toy
1 h
3,9 0,9 120 min Portable lighting
b
(see note)
6,8 0,9 3,0 h Tape recorders
1 h
R14S 1,5 50,0 48,6 13,0 0,9 7,5 1,5 26,2 24,9 1,0
(standard)
20 0,9 15 h Radio
4 h
3,9 0,8 1,5 h Toy
1 h
2,2 0,9 300 min Portable lighting (1)
b
3,9 0,9 9 h Tape recorders
1 h
10 0,9 30 h Radio
R20C 1,5 61,5 59,5 18,0 1,0 9,5 1,5 34,2 32,3 1,0 4 h
(high capacity)
2,2 0,8 4 h Toy
1 h
1,5 0,9 130 min Portable lighting (2)
4 min/15 min
8 h per day
NOTE Delayed discharge performance after 12 months is 80 % of MAD.
a
Standard conditions (see IEC 60086-1, 6.1 Table 4, Initial discharge test).
b
4 min beginning at hourly intervals for 8 h per day.

---------------------- Page: 8 ----------------------

– 13 –
60086-2 Amend.2  IEC:2004(E)


PHYSICAL AND ELECTRICAL SPECIFICATIONS CATEGORY 1 BATTERIES
Dimensions
Discharge conditions
a

Electro- mm
MAD
Vn
chemical Designation Applications
A B C E F G
∅ ∅P
R EV
V
(initial)
system Daily period
Max. Min. Min. Max. Max. Min. Max. Min. Max.
V
Ω
b
2,2 0,9 320 min Portable lighting (1)
1 h
3,9 0,9 13 h Tape recorders
R20P
4 h
10 0,9 35 h Transistor radios
1,5 61,5 59,5 18,0 1,0 9,5 1,5 34,2 32,3 1,0
(high power)
1 h
2,2 0,8 6 h Toys
4 min per 15 min
1,5 0,9 137 min Portable lighting (2)
8 h per day
b
(see note 1)
2,2 0,9 100 min Portable lighting (1)
1 h
3,9 0,9 4 h Tape recorders
R20S
4 h
10 0,9 18 h Transistor radios
1,5 61,5 59,5 18,0 1,0 9,5 1,5 34,2 32,3 1,0
(standard)
1 h
2,2 0,8 2 h Toys
4 min per 15 min
1,5 0,9 32 min Portable lighting (2)
8 h per day
5 min
2R10
3,0 74,6 71,5 9,0 0,8 6,8 1,0 21,8 20,0 6,8 1,8 85 min Portable lighting
5 min
5,1 0,9 90 min Lighting

c 1 h
LR8D425 1,5 42,5 41,5 0,1 3,8 0,7 8,3 7,7 0,1 75 1,1 22 h Laser pointer
2,3
1 h
L 75 0,9 27 h Service output test
12 h
(see note 2) 300 0,9 130 h Hearing aids
5 min
LR1 1,5 30,2 29,1 5,0 0,2 4,0 0,5 12,0 10,9 0,5 5,1 0,9 94 min Portable lighting
d
3 000 0,9 888 h Paging test
NOTE 1 Delayed discharge performance after 12 months is 80 % of MAD.
NOTE 2 Delayed discharge performance after 12 months is 90 % of MAD.
a
Standard conditions (see IEC 60086-1, 6.1, Table 4, Initial discharge test).                                    Example
b
4 min beginning at hourly intervals for 8 h per day.
c
Background load Pulse load Off load
This battery does not fulfill the requirement
  C > F due to constructional constraints.
d
24 h per day, plus 10 Ω for 5 s at hourly
  intervals for 24 h per day. See example.

---------------------- Page: 9 ----------------------

– 14 –
60086-2 Amend.2  IEC:2004(E)


PHYSICAL AND ELECTRICAL SPECIFICATIONS CATEGORY 1 BATTERIES
Dimensions
Discharge conditions
a

Electro- mm
Vn MAD
chemical Designation Applications

A B C E F G ∅ ∅P R EV
V (initial)
system
Daily period
V
Max. Min. Min. Max. Max. Min. Max. Min. Max. Ω
5,1 b 0,9 130 min Portable lighting
15 s per min
24 1,0 14,5 h Remote control
8 h per day
Personal cassette
LR03 1,5 44,5 43,3 4,3 0,5 3,8 0,8 10,5 9,5 0,4
10 1 h 0,9 5 h
player and tape recorder
75 4 h 0,9 44 h Radio
(current drain)
c
0,9 140 pulses Photo flash
600 mA
43 4 h 0,9 60 h Radio
3,9 1 h 0,8 4 h Motor/toy
Personal cassette player and
10 1 h 0,9 11,5 h
tape recorder
(current drain)
LR6 1,5 50,5 49,2 7,0 0,5 5,5 1,0 14,5 13,5 0,5
1 h 0,9 4,5 h CD/MD/ Electronic game
250 mA
(current drain)
L
c 0,9 200 pulses Photo flash
1 000 mA
(see note)
15 s per min
24 1,0 31 h Remote control
8 h per day
3,9 b 0,9 770 min Portable lighting
(current drain)
2 h 0,9 8 h Portable stereo
400 mA
LR14 1,5 50,0 48,6 13,0 0,9 7,5 1,5 26,2 24,9 1,0
20 4 h 0,9 77 h Radio
3,9 1 h 0,8 12 h Toy
2,2 b 0,9
810 min Portable lighting (1)
(current drain) 2 h 0 , 9 11 h Portable stereo
600 mA
LR20 1,5 61,5 59,518,01,0 9,5 1,5 34,232,31,0 10 4 h 0,981 h Radio
2,2 1 h 15 h Toy
0,8
4 min per 15 min
1,5 0 , 9 450 min Portable lighting (2)
8 h per day
NOTE Delayed discharge performance after 12 months is 90 % of MAD.
a
Standard conditions (see IEC 60086-1, 6.1, Table 4, Initial disc
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.