IEC 60086-3:2021 is available as IEC 60086-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60086-3-5:2021 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.

  • Standard
    24 pages
    English language
    sale 15% off

IEC 60086-2:2021 is applicable to primary batteries which are based on standardised electrochemical systems.
It specifies
– the physical dimensions,
– the discharge test conditions and discharge performance requirements.

  • Standard
    58 pages
    English language
    sale 15% off

IEC 60086-1:2021 is available as IEC 60086-1:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60086-1:2021 is intended to standardize primary batteries with respect to dimensions, nomenclature, terminal configurations, markings, test methods, typical performance, safety and environmental aspects. This document on one side specifies requirements for primary cells and batteries. On the other side, this document also specifies procedures of how requirements for these batteries are to be standardised. As a classification tool for primary batteries, this document specifies system letters, electrodes, electrolytes, and nominal as well as maximum open circuit voltage of electrochemical systems. The object of this part of IEC 60086 is to benefit primary battery users, device designers and battery manufacturers by ensuring that batteries from different manufacturers are interchangeable according to standard form, fit and function. Furthermore, to ensure compliance with the above, this part specifies standard test methods for testing primary cells and batteries.

  • Standard
    97 pages
    English and French language
    sale 15% off

TAN - // IEC Corrigendum

  • Corrigendum
    3 pages
    French language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60086-6 applies to all chemistries of portable primary cells and batteriesstandardized in the 60086 series.The purpose of this document is to provide guidance on the proper scientific protocols fortesting the environmental performance of batteries; the symbols used to convey messages forcollection, recycling, or other ideas; and the aspects and functional unit(s) to be included inassessing the environmental impact of batteries with modern life-cycle analysis techniques.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-6:2020 applies to all chemistries of portable primary cells and batteries standardized in the 60086 series. The purpose of this document is to provide guidance on the proper scientific protocols for testing the environmental performance of batteries; the symbols used to convey messages for collection, recycling, or other ideas; and the aspects and functional unit(s) to be included in assessing the environmental impact of batteries with modern life-cycle analysis techniques

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-6:2020 applies to all chemistries of portable primary cells and batteries standardized in the 60086 series.
The purpose of this document is to provide guidance on the proper scientific protocols for testing the environmental performance of batteries; the symbols used to convey messages for collection, recycling, or other ideas; and the aspects and functional unit(s) to be included in assessing the environmental impact of batteries with modern life-cycle analysis techniques

  • Standard
    67 pages
    English and French language
    sale 15% off

This part of IEC 60086 specifies tests and requirements for primary lithium batteries to ensure
their safe operation under intended use and reasonably foreseeable misuse.
NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable
requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring
and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is
made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular
purposes or needs.

  • Corrigendum
    3 pages
    French language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60086 specifies tests and requirements for primary lithium batteries to ensure
their safe operation under intended use and reasonably foreseeable misuse.
NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable
requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring
and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is
made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular
purposes or needs.

  • Corrigendum
    3 pages
    French language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60086 specifies tests and requirements for primary lithium batteries to ensure
their safe operation under intended use and reasonably foreseeable misuse.
NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable
requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring
and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is
made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular
purposes or needs.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-4:2019 is available as IEC 60086-4:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60086-4:2019 specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse. NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular purposes or needs. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Revised criteria for an explosion; b) Addition of test parameters for the overdischarge test of battery types FR14505 and FR10G445; c) Addition of a new subclause 5.1 Validity of Testing; d) revised pictogram E in Table D.1; e) Addition of Annex E with requirements for child resistant packaging of coin cells; f) Addition of Annex F with recommendations on the use of the KEEP OUT OF REACH OF CHILDREN safety sign. Keywords: lithium batteries The contents of the corrigendum of October 2019 have been included in this copy.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies test methods and requirements for primary and
secondary (rechargeable) lithium cells and batteries to ensure their safety during transport
other than for recycling or disposal. Requirements specified in this document do not apply in
those cases where special provisions given in the relevant regulations, listed in 7.3, provide
exemptions.
NOTE Different standards may apply for lithium-ion traction battery systems used for electrically propelled road
vehicles.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies test methods and requirements for primary and secondary (rechargeable) lithium cells and batteries to ensure their safety during transport other than for recycling or disposal. Requirements specified in this document do not apply in those cases where special provisions given in the relevant regulations, listed in 7.3, provide exemptions. NOTE Different standards may apply for lithium-ion traction battery systems used for electrically propelled road vehicles.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-4:2019 is available as IEC 60086-4:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-4:2019 specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse. NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular purposes or needs. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Revised criteria for an explosion;
b) Addition of test parameters for the overdischarge test of battery types FR14505 and FR10G445;
c) Addition of a new subclause 5.1 Validity of Testing;
d) revised pictogram E in Table D.1;
e) Addition of Annex E with requirements for child resistant packaging of coin cells;
f) Addition of Annex F with recommendations on the use of the KEEP OUT OF REACH OF CHILDREN safety sign.
Keywords: lithium batteries
The contents of the corrigendum of October 2019 and April 2020 and the Interpretation sheet of May 2020 have been included in this copy.

  • Standard
    90 pages
    English and French language
    sale 15% off

IEC 62281:2019 is available as IEC 62281:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62281:2019 specifies test methods and requirements for primary and secondary (rechargeable) lithium cells and batteries to ensure their safety during transport other than for recycling or disposal. Requirements specified in this document do not apply in those cases where special provisions given in the relevant regulations, listed in 7.3, provide exemptions. NOTE Different standards may apply for lithium-ion traction battery systems used for electrically propelled road vehicles. This fourth edition cancels and replaces the third edition published in 2016. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:
a) button cell definition revised, moved to coin (cell or battery);
b) addition of provisions for batteries forming an integral part of equipment (5.4);
c) all tests for secondary cells and batteries now also contain a requirement for 25 charge and recharge cycles prior to the test;
d) addition of alternative tables for Table 1 and Table 2 in Annex B;
e) addition of "forcible" to the rupture criteria;
f) test report 6.8 merged with test certificate 6.9 and replaced with the items listed in [13];
g) addition of an informative Annex B with important deviations from the UN Manual of Tests and Criteria, Chapter 38.3.
Keywords: transport of primary lithium cells and batteries

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 62899-501-1:2019(E) specifies failure modes and mechanical stress test methods for the determination of reliability characteristics of bendable or flexible printed primary cells and secondary cells and batteries as defined in IEC 60050-482:2004, 482-01-01, IEC 60050‑482:2004, 482-01-02, IEC 60050-482:2004, 482-01-03, IEC 60050-482:2004, 482‑01-04 and IEC 60050-482:2004, 482-01-05, respectively.
Important parameters and specifications for primary cells are mentioned in IEC 60086-1 and IEC 60086-2. IEC 61960-3, as well as IEC 61951-1 and IEC 61951-2 define performance tests, designations, markings, dimensions and other requirements for secondary single cells and batteries. IEC 62133-1 and IEC 62133-2 address general safety requirements of secondary cells and batteries.

  • Standard
    15 pages
    English language
    sale 15% off

This part of IEC 62952 specifies requirements and a profile for a power source containing a
generic energy harvesting adapter module (GEHAM) used as power source for wireless
communication devices (WCD).

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-3:2017 specifies requirements and a profile for a power source containing a generic energy harvesting adapter module (GEHAM) used as power source for wireless communication devices (WCD).

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-2:2016 specifies a profile for a power module containing batteries used as power
source for wireless communication devices.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62952 specifies the general requirements of power modules for wireless
communication devices (WCD). This document includes additional optional specifications to
permit use in explosive atmospheres and harsh environments.
This document specifies the usability over the life-cycle of a power module including replacing
in explosive atmosphere.Unreplaceable batteries such as memory backup are out of the
scope of this standard.
Secondary batteries or power modules are covered by this document, but method of its power
charging is out of scope.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-3:2017 specifies requirements and a profile for a power source containing a generic energy harvesting adapter module (GEHAM) used as power source for wireless communication devices (WCD).

  • Standard
    38 pages
    English and French language
    sale 15% off

This International Standard specifies test methods and requirements for primary and
secondary (rechargeable) lithium cells and batteries to ensure their safety during transport
other than for recycling or disposal. Requirements specified in this standard do not apply in
those cases where special provisions given in the relevant regulations, listed in 7.3, provide
exemptions.
NOTE Different standards may apply for lithium-ion traction battery systems used for electrically propelled road
vehicles.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 62281:2016 is available as IEC 62281:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62281:2016 specifies test methods and requirements for primary and secondary (rechargeable) lithium cells and batteries to ensure their safety during transport other than for recycling or disposal. Requirements specified in this standard do not apply in those cases where special provisions given in the relevant regulations, listed in 7.3, provide exemptions. NOTE - Different standards may apply for lithium-ion traction battery systems used for electrically propelled road vehicles. This third edition cancels and replaces the second edition, published in 2012, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Deletion of the wire mesh screen from the evaluation of test criteria for an explosion; - Extension / modification of the shock test parameters so as to achieve constant energy behaviour for large batteries as well as explanations in a new Annex A; - Modification of the external short-circuit method so as to allow the short-circuit to be applied to large batteries after they have been removed from the temperature chamber; - Change of the cell diameter distinguishing between impact and crush test from 20 mm to 18 mm; - Addition of possible content for a transport certificate. Keywords: test methods and requirements for primary and secondary (rechargeable) lithium cells and batteries, transport certificate

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-1:2016 specifies the general requirements of power modules for wireless communication devices (WCD). This document includes additional optional specifications to permit use in explosive atmospheres and harsh environments. This International Standard is based on VDI/VDE 2185 Blatt 3.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-2:2016 specifies a profile for a power module containing batteries used as power source for wireless communication devices.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-5:2011 specifies tests and requirements for primary batteries with aqueous electrolyte to ensure their safe operation under intended use and reasonably foreseeable misuse. The major technical changes with respect to the previous edition are the test requirements and the harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of safety pictograms was added as Annex C

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-5:2011 specifies tests and requirements for primary batteries with aqueous electrolyte to ensure their safe operation under intended use and reasonably foreseeable misuse. The major technical changes with respect to the previous edition are the test requirements and the harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of safety pictograms was added as Annex C

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-3:2011(E) specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62952-1:2016 specifies the general requirements of power modules for wireless communication devices (WCD). This document includes additional optional specifications to permit use in explosive atmospheres and harsh environments. This International Standard is based on VDI/VDE 2185 Blatt 3.

  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 62952-2:2016 specifies a profile for a power module containing batteries used as power source for wireless communication devices.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 60086-3:2011(E) specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-5:2016 is available as IEC 60086-5:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-5:2016 specifies tests and requirements for primary batteries with aqueous electrolyte to ensure their safe operation under intended use and reasonably foreseeable misuse. This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The definition of explosion was changed to suitable sentence in order to harmonize in IEC 60086 series;
- To prevent removal of hydrogen gas, we revised it to the suitable sentence;
- To prevent misuse, the battery compartments with parallel connections were revised to the suitable sentence;
- To clarify the method to determine the insulation resistance. Keywords: tests and requirements for primary batteries

  • Standard
    76 pages
    English and French language
    sale 15% off

IEC 60086-3:2016 is available as IEC 60086-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3:2016 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- A harmonization of the cell sizes and service output tests with IEC 60086-2;
- Clarifications of Clauses 6: Sampling and Quality Assurance, 7: Test methods, and 8: Visual examination and acceptance condition;
- Harmonization of temperature and humidity conditions with IEC 60086-1. This publication is published as a double logo standard. Keywords: primary batteries for watches

  • Standard
    50 pages
    English and French language
    sale 15% off

This part of IEC 60086 is applicable to primary batteries based on standardized electrochemical
systems.
It specifies
– the physical dimensions,
– the discharge test conditions and discharge performance requirements.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-2:2015 is applicable to primary batteries based on standardized electrochemical systems. It specifies the physical dimensions, the discharge test conditions and discharge performance requirements. This thirteenth edition cancels and replaces the twelfth edition (2011) and constitutes a technical revision. Significant changes from the previous edition are test changes to battery types R03, LR03, R6, LR6, PR70, PR41, PR48, 6F22, 6LR61, 6LP3146 4LR25-2, R14, LR14, R20, LR20, CR2025, and CR2032, adding the 5AR40 back into the standard, addition of common designations, addition of two new battery types FR14505 and FR10G445, deletion of battery types LR53, R40, 2EP3863, 6F100, and general editorial changes. Keywords: primary batteries, electrochemical systems

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60086 is intended to standardize primary batteries with respect to dimensions,
nomenclature, terminal configurations, markings, test methods, typical performance, safety
and environmental aspects.
As a primary battery classification tool, electrochemical systems are also standardized with
respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage.
NOTE The requirements justifying the inclusion or the ongoing retention of batteries in the IEC 60086 series are
given in Annex A.
The object of this part of IEC 60086 is to benefit primary battery users, device designers and
battery manufacturers by ensuring that batteries from different manufacturers are
interchangeable according to standard form, fit and function. Furthermore, to ensure
compliance with the above, this part specifies standard test methods for testing primary cells
and batteries.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-2:2015 is applicable to primary batteries based on standardized electrochemical systems. It specifies the physical dimensions, the discharge test conditions and discharge performance requirements. This thirteenth edition cancels and replaces the twelfth edition (2011) and constitutes a technical revision. Significant changes from the previous edition are test changes to battery types R03, LR03, R6, LR6, PR70, PR41, PR48, 6F22, 6LR61, 6LP3146 4LR25-2, R14, LR14, R20, LR20, CR2025, and CR2032, adding the 5AR40 back into the standard, addition of common designations, addition of two new battery types FR14505 and FR10G445, deletion of battery types LR53, R40, 2EP3863, 6F100, and general editorial changes. Keywords: primary batteries, electrochemical systems

  • Standard
    107 pages
    English and French language
    sale 15% off

IEC 60086-1:2015 is available as IEC 60086-1:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60086-1:2015(E) is intended to standardize primary batteries with respect to dimensions, nomenclature, terminal configurations, markings, test methods, typical performance, safety and environmental aspects. As a primary battery classification tool, electrochemical systems are also standardized with respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage. The object of this part of IEC 60086 is to benefit primary battery users, device designers and battery manufacturers by ensuring that batteries from different manufacturers are interchangeable according to standard form, fit and function. Furthermore, to ensure compliance with the above, this part specifies standard test methods for testing primary cells and batteries. This twelfth edition cancels and replaces the eleventh edition (2011) and constitutes a technical revision. The major technical changes with respect to the previous edition are:
- the order of the Annexes was changed to the order in which they appearin the document and a caption was added to indicate where the Annex information first appears in the document; - the humidity conditions for non P-system batteries in Table 3 was modified; - the standard discharge voltage for the Y and W chemistries was determined to be at 3,5 V and 2,8 V respectively; - details on capacity measurement were moved from Annex E to Subclause 5.1. - the coin/button cell and battery definition was clarified in order to better address issues with the swallowing of coin cells. Keywords: fundamental requirements and information on primary cells and batteries

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-1:2015 is available as IEC 60086-1:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-1:2015 is intended to standardize primary batteries with respect to dimensions, nomenclature, terminal configurations, markings, test methods, typical performance, safety and environmental aspects. As a primary battery classification tool, electrochemical systems are also standardized with respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage. The object of this part of IEC 60086 is to benefit primary battery users, device designers and battery manufacturers by ensuring that batteries from different manufacturers are interchangeable according to standard form, fit and function. Furthermore, to ensure compliance with the above, this part specifies standard test methods for testing primary cells and batteries. This twelfth edition cancels and replaces the eleventh edition (2011) and constitutes a technical revision. The major technical changes with respect to the previous edition are:
- the order of the Annexes was changed to the order in which they appearin the document and a caption was added to indicate where the Annex information first appears in the document;
- the humidity conditions for non P-system batteries in Table 3 was modified;
- the standard discharge voltage for the Y and W chemistries was determined to be at 3,5 V and 2,8 V respectively;
- details on capacity measurement were moved from Annex E to Subclause 5.1.
- the coin/button cell and battery definition was clarified in order to better address issues with the swallowing of coin cells. Keywords: fundamental requirements and information on primary cells and batteries

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    93 pages
    English and French language
    sale 15% off

This Part of IEC 60086 specifies tests and requirements for primary lithium batteries to ensure
their safe operation under intended use and reasonably foreseeable misuse.
NOTE Primary lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable
requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring
and/or ensuring the safety of non-standardized primary lithium batteries. In either case, no claim or warranty is
made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user’s particular
purposes or needs.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-4:2014 specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse. This fourth edition cancels and replaces the third edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Harmonisation with the second edition of IEC 62281; - Alternative protective circuits in 7.1.1; - More information regarding risks of swallowing lithium batteries in (former) 7.2.m) and promotion of this item to 7.2a); - A new Annex D with pictograms for some of the safety precautions in 7.2. Keywords: lithium batteries

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    16 pages
    English language
    sale 15% off

TAN - // IEC Corrigendum

  • Corrigendum
    3 pages
    French language
    sale 10% off
    e-Library read for
    1 day

Gives the general terminology used in the fields of primary and secondary cells and batteries, and reflects the technology, design, construction, performance and application employed.
It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard
    146 pages
    English and French language
    sale 15% off

This International Standard specifies test methods and requirements for primary and secondary (rechargeable) lithium cells and batteries to ensure their safety during transport other than for recycling or disposal. Requirements specified in this standard do not apply in those cases where special provisions given in the relevant regulations, listed in 7.3, provide exemptions.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day