Preparation of steel substrates before application of paints and related products - Surface roughness characteristics of blast-cleaned steel substrates - Part 4: Method for the calibration of ISO surface profile comparators and for the determination of surface profile - Stylus instrument procedure (ISO 8503-4:1988)

Based on the measurement of the peaks and valleys by vertical displacement of a stylus traversing the test surface in the direction of travel over the specified traversing length. Determination of the mean maximum peak-to-valley height. Repetition of the procedure to obtain values on not less than ten different locations, followed by the calculation of the grand mean value. The procedure is also applicable to the determination of the surface profile of essentially planar blast-cleaned steel.

Vorbereitung von Stahloberflächen vor dem Auftragen von Beschichtungsstoffen - Rauheitskenngrößen von gestrahlten Stahloberflächen - Teil 4: Verfahren zur Kalibrierung von ISO-Rauheitsvergleichsmustern und zur Bestimmung der Rauheit - Tastschnittverfahren (ISO 8503-4:1988)

Dieser Teil von ISO 8503 beschreibt das Tastschnittgerät und das Verfahren zur Kalibrierung von ISO-Rauheitsvergleichsmustern, welche den Anforderungen nach ISO 8503-1 entsprechen.

Préparation des subjectiles d'acier avant application de peintures et de produits assimilés - Caractéristiques de rugosité des subjectiles d'acier décapés - Partie 4: Méthode pour étalonner les échantillons de comparaison viso-tactile ISO et pour caractériser un profil de surface - Utilisation d'un appareil a palpeur (ISO 8503-4:1988)

1.1 La présente partie de l'ISO 8503 décrit l'appareil à palpeur et la méthode pour étalonner les échantillons de comparaison viso-tactile ISO répondant aux exigences de l'ISO 8503-1. 1.2 La présente partie de l'ISO 8503 est également applicable à la détermination d'un profil de surface Ry5, dans la gamme de 20 à 200 µm, d'une surface essentiellement plane décapée par projection d'abrasif. La détermination peut être effectuée sur une partie représentative de la surface préparée ou, si l'observation directe n'est pas possible, sur une réplique (voir annexe C).
NOTE -- Dans certains cas, ce mode opératoire peut convenir pour évaluer le profil de rugosité d'autres subjectiles décapés par projection d'abrasif. Une autre méthode est décrite dans l'ISO 8503-3.

Priprava jeklenih podlag pred nanašanjem barvnih in sorodnih premazov - Površinske hrapave karakteristike peskanih jeklenih podlag - 4. del: Metoda za kalibracijo lestvice standardov površinske hrapavosti ISO in za določanje hrapavosti površine - Postopek z instrumentom Stylus (ISO 8503-4:1988)

General Information

Status
Withdrawn
Publication Date
30-Nov-1997
Withdrawal Date
25-Mar-2012
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
23-Mar-2012
Due Date
15-Apr-2012
Completion Date
26-Mar-2012

Relations

Buy Standard

Standard
EN ISO 8503-4:1997
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 8503-4:1997
01-december-1997
3ULSUDYDMHNOHQLKSRGODJSUHGQDQDãDQMHPEDUYQLKLQVRURGQLKSUHPD]RY
3RYUãLQVNHKUDSDYHNDUDNWHULVWLNHSHVNDQLKMHNOHQLKSRGODJGHO0HWRGD]D
NDOLEUDFLMROHVWYLFHVWDQGDUGRYSRYUãLQVNHKUDSDYRVWL,62LQ]DGRORþDQMH
KUDSDYRVWLSRYUãLQH3RVWRSHN]LQVWUXPHQWRP6W\OXV ,62
Preparation of steel substrates before application of paints and related products -
Surface roughness characteristics of blast-cleaned steel substrates - Part 4: Method for
the calibration of ISO surface profile comparators and for the determination of surface
profile - Stylus instrument procedure (ISO 8503-4:1988)
Vorbereitung von Stahloberflächen vor dem Auftragen von Beschichtungsstoffen -
Rauheitskenngrößen von gestrahlten Stahloberflächen - Teil 4: Verfahren zur
Kalibrierung von ISO-Rauheitsvergleichsmustern und zur Bestimmung der Rauheit -
Tastschnittverfahren (ISO 8503-4:1988)
Préparation des subjectiles d'acier avant application de peintures et de produits
assimilés - Caractéristiques de rugosité des subjectiles d'acier décapés - Partie 4:
Méthode pour étalonner les échantillons de comparaison viso-tactile ISO et pour
caractériser un profil de surface - Utilisation d'un appareil a palpeur (ISO 8503-4:1988)
Ta slovenski standard je istoveten z: EN ISO 8503-4:1995
ICS:
25.220.10 Priprava površine Surface preparation
87.020 Postopki za nanašanje Paint coating processes
barvnih premazov
SIST EN ISO 8503-4:1997 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 8503-4:1997

---------------------- Page: 2 ----------------------

SIST EN ISO 8503-4:1997

---------------------- Page: 3 ----------------------

SIST EN ISO 8503-4:1997

---------------------- Page: 4 ----------------------

SIST EN ISO 8503-4:1997

---------------------- Page: 5 ----------------------

SIST EN ISO 8503-4:1997

---------------------- Page: 6 ----------------------

SIST EN ISO 8503-4:1997
IS0
INTERNATIONAL STANDARD
8503-4
First edition
1988-02-01
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
ORGANISATION INTERNATIONALE DE NORMALISATION
MEXP,YHAPOAHAfl OPTAHM3A~MR IlO CTAHflAPTM3A~MM
Preparation of steel substrates before application of
paints and related products - Surface roughness
characteristics of blast-cleaned steel substrates -
Part 4 :
Method for the calibration of IS0 surface profile
comparators and for the determination of surface profile -
Stylus instrument procedure
Preparation des subjectiles d’acier avant application de peintures et de produits assimif& -
Caractkistiques de rugosit6 des subjectiles d’acier d&cap& -
Partie 4 : M&hode pour &alonner les e’chantillons de comparaison viso-tactile /SO et pour
caractkriser un profil de surface - Utilisation d’un appareil ;i palpeur
Reference number
IS0 8503-4: 1988 (E)

---------------------- Page: 7 ----------------------

SIST EN ISO 8503-4:1997
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Each member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 8503-4 was prepared by Technical Committee ISO/TC 35,
Paints and varnishes.
Users should note that all International Standards undergo revision from time to time
and that any reference made herein to any other International Standard implies its
latest edition, unless otherwise stated.
0 International Organization for Standardization, 1988
Printed in Switzerland

---------------------- Page: 8 ----------------------

SIST EN ISO 8503-4:1997
IS0 8503-4 : 1988 (E)
INTERNATIONAL STANDARD
Preparation of steel substrates before application of
paints and related products - Surface roughness
characteristics of blast-cleaned steel substrates -
Part 4 I
Method for the calibration of IS0 surface profile
comparators and for the determination of surface profile -
Stylus instrument procedure
IS0 8502 - Tests for the assessment of surface clean-
0 Introduction
liness;
The performance of protective coatings of paint and related
- Surface roughness characteristics of blast-
IS0 8503
products applied to steel is significantly affected by the state of
cleaned steel substrates;
the steel surface immediately prior to painting. The principal
factors that are known to influence this performance are
IS0 8504 - Surface preparation methods.
Each of these International Standards is in turn divided into
a) the presence of rust and mill scale;
separate parts.
b) the presence of surface contaminants, including salts,
The stylus instrument is commonly used in the precision
dust, oils and greases;
measurement of surface textures resulting from machining and
c) the surface profile. abrading procedures. The method is highly reproducible and
totally independent of the operator and, if required, some in-
International Standards IS0 8501, IS0 8502 and IS0 8503 have struments can provide a graphical representation of the sur-
been prepared to provide methods of assessing these factors,
face. This procedure may also be used to determine the profile
while IS0 8504 provides guidance on the preparation methods of a substrate after abrasive blast-cleaning either directly or
that are available for cleaning steel substrates, indicating the from a replica.
capabilities of each in attaining specified levels of cleanliness.
IS0 8503-3 describes the procedure using a focusing micro-
scope. IS0 8503-l specifies the requirements for IS0 surface
These International Standards do not contain recommenda-
profile comparators, and IS0 8503-2 describes the procedure
tions for the protective coating systems to be applied to the
for their use. The many abrasive blast-cleaning procedures in
steel surface. Neither do they contain recommendations for the
common use are described in IS0 8504-2.
surface quality requirements for specific situations even though
surface quality can have a direct influence on the choice of
protective coating to be applied and on its performance. Such
1 Scope and field of application
recommendations are found in other documents such as
national standards and codes of practice. It will be necessary 1 .I This part of IS0 8503 specifies the stylus instrument and
for the users of these International Standards to ensure that the
describes the procedure for calibrating IS0 surface profile com-
qualities specified are parators complying with the requirements of IS0 8503-I.
-
compatible and appropriate both for the environmental
This part of IS0 8503 is also applicable to the determina-
1.2
conditions to which the steel will be exposed and for the
tion of the surface profile, within the range Ry5 = 20 to 200 pm,
protective coating system to be used;
of essentially planar blast-cleaned steel. The determination may
be carried out on a representative section of the blast-cleaned
-
within the capability of the cleaning procedure speci-
surface or, if direct observation of the surface is not feasible, on
fied.
a replica of the surface (see annex CL
The four International Standards referred to above deal with
NOTE - Where appropriate, this procedure may be used for assessing
the following aspects of preparation of steel substrates :
the roughness profile of other abrasive blast-cleaned substrates.
IS0 8501 - Visual assessment of surface cleanliness; An alternative procedure is described in IS0 8503-3.
1

---------------------- Page: 9 ----------------------

SIST EN ISO 8503-4:1997
IS0 8503-4 : 1988 (E)
2 References Determination of the mean maximum peak-to-valley height,
Ry5 by the equipment in accordance with the instructions of
IS0 3274, Instruments for the measurement of surface the instrument manufacturer.
roughness by the profile method - Contact transformation -
Repetition of the procedure to obtain values at not less than 10
Contact profile meters, system M.
different locations on the test surface and calculation of the
grand mean maximum peak-to-valley height Rys.
IS0 4287-1, Surface roughness - Terminology - Part I : Sur-
face and its parameters.
IS0 4618, Paints and varnishes - Vocabulary.
5 Apparatus
IS0 5436, Calibration specimens - Stylus instruments -
complying with the description in
Stylus instrument,
Types, calibration and use of specimens.
IS0 3274, and equipped with a diamond stylus in good con-
dition assessed as described in IS0 5436. The tip radius shall be
IS0 8503, Preparation of steel substrates before application of
5 Z!I 1 pm. The stylus shall traverse an evaluation length I, of
paints and related products - Surface roughness character-
12,5 mm and the corresponding sampling length I shall be
is tics of blast- cleaned steel substrates
2,5 mm. The rate of traverse of the stylus shall be not greater
than 1,0 mm/s.
- Part 7 : Specifications and definitions for IS0 surface
profile comparators for the assessment of abrasive blast-
cleaned surfaces.
6 Test surfaces
- Part 2 : Method for the grading of surface profile of
abrasive blast-cleaned steel - Comparator procedure.
6.1 IS0 surface profile comparator
Visually check that each segment of the IS0 surface profile
- Part 3 : Method for the calibration of IS0 surface
comparator (see IS0 8503-l) that is
...

Questions, Comments and Discussion