SIST EN 50216-7:2002
(Main)Power transformer and reactor fittings -- Part 7: Electric pumps for transformer oil
Power transformer and reactor fittings -- Part 7: Electric pumps for transformer oil
EN 50216-7 covers requirements for electric pumps which generate the circulation of insulating oil in transformers and reactors conforming to the EN 60076 series and their associated cooling systems.
The pumps covered in this standard are rotodynamic pumps driven by a squirrel cage induction motor which is immersed in the insulating oil.
Pump sets conforming to this standard may be of in-line or end suction design.
This standard includes requirements for the electrical and hydraulic performance, mechanical design, routine testing and type testing. Additionally, performance and dimensions of preferred sizes of pump sets are specified (see normative annexes A and B).
The insulating oils considered comply with subclause 2.5 of IEC 60296-1. If other insulating liquids are to be used, the performance and design of the pump shall be agreed between purchaser and manufacturer.
Zubehör für Transformatoren und Drosselspulen -- Teil 7: Elektrische Pumpen für Transformatorenöl
Dieser Teil der EN 50216 legt Anforderungen an elektrische Pumpen fest, die den Umlauf des Isolieröls in Transformatoren und Drosselspulen nach der Reihe 60076 und deren zugeordneten Kühlungseinrichtungen erzeugen.
Die in dieser Norm behandelten Pumpen sind rotationsdynamische Pumpen, die durch einen Kurzschlussläufermotor angetrieben werden, der im Isolieröl eingetaucht ist.
Pumpensätze, die dieser Norm entsprechen, dürfen als Einbaupumpe oder als Anbaupumpe ausgeführt sein.
Diese Norm beinhaltet Anforderungen an das elektrische und hydraulische Betriebsverhalten, die mechanische Ausführung, die Stückprüfung und die Typprüfung. Zusätzlich sind Betriebsverhalten und Abmessungen von bevorzugten Pumpensätzen festgelegt (siehe normative Anhänge A und B).
Die betrachteten Isolieröle entsprechen IEC 60296-1, Abschnitt 2.5. Falls andere Isolierflüssigkeiten zur Anwendung kommen, müssen das Betriebsverhalten und die Ausführung der Pumpe zwischen Käufer und Hersteller vereinbart werden.
Accessoires pour transformateurs de puissance et bobines d'inductance -- Partie 7: Pompes électriques pour transformateur immergé
La EN 50216-7 concerne les règles des groupes électropompes qui engendrent la circulation des huiles isolantes des transformateurs et des inductances conformes à la série de normes EN 60076 et leurs systèmes de refroidissement associés.
Cette norme concerne uniquement les groupes constitués d'une pompe centrifuge et d'un moteur asynchrone triphasé à rotor en court-circuit complètement immergé dans l'huile isolante.
La conception des pompes conformes à cette norme peut présenter une circulation du fluide en ligne ou radiale.
Cette norme définit les caractéristiques électriques et hydrauliques, la conception mécanique, les essais de série et de type. D'autre part, les performances et dimensions recommandées des pompes sont spécifiées (voir annexes A et B).
Les huiles isolantes considérées répondent au paragraphe 2.5 de la CEI 60296 1. Si d'autres liquides isolants sont utilisés, les caractéristiques et la conception de la pompe feront l'objet d'un accord entre l'acheteur et le constructeur.
Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50216-7:2002
01-oktober-2002
Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil
Power transformer and reactor fittings -- Part 7: Electric pumps for transformer oil
Zubehör für Transformatoren und Drosselspulen -- Teil 7: Elektrische Pumpen für
Transformatorenöl
Accessoires pour transformateurs de puissance et bobines d'inductance -- Partie 7:
Pompes électriques pour transformateur immergé
Ta slovenski standard je istoveten z: EN 50216-7:2002
ICS:
29.180 Transformatorji. Dušilke Transformers. Reactors
SIST EN 50216-7:2002 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50216-7:2002
---------------------- Page: 2 ----------------------
SIST EN 50216-7:2002
EUROPEAN STANDARD EN 50216-7
NORME EUROPÉENNE
EUROPÄISCHE NORM January 2002
ICS 29.180
English version
Power transformer and reactor fittings
Part 7: Electric pumps for transformer oil
Accessoires pour transformateurs Zubehör für Transformatoren
de puissance et bobines d'inductance und Drosselspulen
Partie 7: Pompes électriques Teil 7: Elektrische Pumpen
pour transformateur immergé für Transformatorenöl
This European Standard was approved by CENELEC on 2001-07-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any
other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50216-7:2002 E
---------------------- Page: 3 ----------------------
SIST EN 50216-7:2002
EN 50216-7:2002 - 2 -
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 14, Power
transformers.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50216-7 on 2001-07-01.
The following dates were fixed:
- latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-08-01
- latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2004-08-01
EN 50216-7 is to be read in conjunction with EN 50216-1.
__________
---------------------- Page: 4 ----------------------
SIST EN 50216-7:2002
- 3 - EN 50216-7:2002
Contents
Page
1 Scope . 4
2 Normative references. 4
3 Definitions. 5
4 Design . 5
4.1 General. 5
4.2 Casing/enclosure . 6
4.3 Terminal box . 6
4.4 Hydraulic performance. 6
4.5 Electrical performance . 8
4.6 Noise. 8
4.7 Labelling . 8
5 Materials. 9
6 Preferred sizes .
...
Questions, Comments and Discussion