Connectors for electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking (IEC 61076-2-111:2017)

This part of IEC 61076-2 specifies 4 to 6-way circular connectors with M12 screw-locking with
current ratings up to 16 A and voltage ratings of 63 V or 630 V, that are typically used for
power supply and power applications in industrial premises. These connectors consist of both
fixed and free connectors either rewireable or non-rewireable, with M12 screw-locking. Male
connectors have round contacts Ø1,0 mm and Ø1,5 mm.
The different codings provided by this document prevent the mating of accordingly coded
male or female connectors to any other similarly sized interfaces, covered by other standards
and the cross-mating between the different codings provided by this document.
NOTE M12 is the dimension of the thread of the screw-locking mechanism of these circular connectors.

Steckverbinder für elektronische Einrichtungen – Produktanforderungen – Teil 2-111: Rundsteckverbinder – Bauartspezifikation für Leistungs-Steckverbinder mit Schraubverriegelung M12

Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-111 : Connecteurs circulaires - Spécification particulière pour les connecteurs d’alimentation à vis M12

IEC 61076-2-111:2017 spécifie les connecteurs circulaires à 4 à 6 pôles à vis M12 avec des courants assignés allant jusqu’à 16 A et des tensions assignées de 63 V ou 630 V, qui sont généralement utilisés pour les applications d’alimentation ou de puissance dans les installations industrielles. Ces connecteurs se composent à la fois d’embases et de fiches, démontables ou non démontables, avec un verrouillage à vis M12. Les connecteurs mâles ont des contacts ronds de Ø 1,0 mm et de Ø 1,5 mm.
Les différents détrompages prévus par le présent document empêchent l’accouplement de connecteurs mâles et femelles équipés de tels détrompeurs avec une quelconque autre interface de taille semblable couverte par d’autres normes, ainsi que l’accouplement croisé entre les différents détrompages prévus par le présent document.
M12 est la dimension du filetage du mécanisme de verrouillage à vis des connecteurs circulaires.
Mots clés: Connecteurs, connecteurs circulaires, M12

Konektorji za elektronsko opremo - Zahteve za izdelek - 2-111. del: Okrogli konektorji - Podrobna specifikacija za močnostne konektorje z vijačnim zaklepanjem M12 (IEC 61076-2-111:2017)

Ta del standarda IEC 61076-2 določa 4- do 6-polne okrogle konektorje z vijačnim zaklepanjem M12, nazivnim tokom do 16 A in nazivno napetostjo 63 V ali 630 V, ki se običajno uporabljajo za potrebe napajanja v industrijskem okolju. Ti konektorji so sestavljeni iz pritrjenih in prostih konektorjev z možnostjo ponovnega ožičenja ali brez ter vijačnim zaklepanjem M12. Moški konektorji imajo okrogle kontakte s premerom 1 mm in 1,5 mm.
Različne označitve, določene v tem dokumentu, preprečujejo stikanje ustrezno označenih moških ali ženskih konektorjev s katerimi koli drugimi podobno velikimi vmesniki, ki so zajeti v drugih standardih, in navzkrižno stikanje med različnimi označitvami, podanimi v tem dokumentu.
OPOMBA: M12 je mera navoja mehanizma z vijačnim zaklepanjem teh okroglih konektorjev.

General Information

Status
Published
Publication Date
09-May-2018
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Mar-2018
Due Date
19-May-2018
Completion Date
10-May-2018

Buy Standard

Standard
EN IEC 61076-2-111:2018
English language
77 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.DþQLPConnectors for electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking (IEC 61076-2-111:2017)31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN IEC 61076-2-111:2018SIST EN IEC 61076-2-111:2018en01-junij-2018SIST EN IEC 61076-2-111:2018SLOVENSKI
STANDARD



SIST EN IEC 61076-2-111:2018



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN IEC 61076-2-111
March 2018 ICS 31.220
English Version
Connectors for electrical and electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking (IEC 61076-2-111:2017)
Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-111 : Connecteurs circulaires - Spécification particulière pour les connecteurs d'alimentation à vis M12 (IEC 61076-2-111:2017)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 2-111: Rundsteckverbinder - Bauartspezifikation für Leistungs-Steckverbinder mit Schraubverriegelung M12 (IEC 61076-2-111:2017) This European Standard was approved by CENELEC on 2018-01-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23,
B-1040 Brussels © 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61076-2-111:2018 E SIST EN IEC 61076-2-111:2018



EN IEC 61076-2-111:2018 (E) 2
European foreword The text of document 48B/2601/FDIS, future edition 1 of IEC 61076-2-111, prepared by IEC/TC 48B "Electrical connectors, of IEC technical committee 48: Electrical connectors and mechanical structures for electrical and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61076-2-111:2018.
The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2018-10-11 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2021-01-11
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice The text of the International Standard IEC 61076-2-111:2017 was approved by CENELEC as a European Standard without any modification.
SIST EN IEC 61076-2-111:2018



EN IEC 61076-2-111:2018 (E) 3 Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1
Where an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
NOTE 2
Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu.
Publication Year Title EN/HD Year IEC 60050-581 2008
International Electrotechnical Vocabulary - Part 581: Electromechanical components for electronic equipment - -
IEC 60068-1 -
Environmental testing -- Part 1: General and guidance EN 60068-1 -
IEC 60068-2-60 -
Environmental testing -- Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test EN 60068-2-60 -
IEC 60352-2 -
Solderless connections -- Part 2: Crimped connections - General requirements, test methods and practical guidance EN 60352-2 -
IEC 60352-3 -
Solderless connections -- Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance EN 60352-3 -
IEC 60352-4 -
Solderless connections -- Part 4: Solderless non-accessible insulation displacement connections - General requirements, test methods and practical guidance EN 60352-4 -
IEC 60352-5 -
Solderless connections -- Part 5: Press-in connections - General requirements, test methods and practical guidance EN 60352-5 -
IEC 60352-6 -
Solderless connections -- Part 6: Insulation piercing connections - General requirements, test methods and practical guidance EN 60352-6 -
IEC 60352-7 -
Solderless connections -- Part 7: Spring clamp connections - General requirements, test methods and practical guidance EN 60352-7 -
IEC 60512-1-1 -
Connectors for electronic equipment - Tests and measurements -- Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 -
SIST EN IEC 61076-2-111:2018



EN IEC 61076-2-111:2018 (E) 4 IEC 60512-1-2 -
Connectors for electronic equipment - Tests and measurements -- Part 1-2: General examination - Test 1b: Examination of dimension and mass EN 60512-1-2 -
IEC 60512-2-1 -
Connectors for electronic equipment - Tests and measurements -- Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method EN 60512-2-1 -
IEC 60512-3-1 -
Connectors for electronic equipment - Tests and measurements -- Part 3-1: Insulation tests - Test 3a: Insulation resistance EN 60512-3-1 -
IEC 60512-4-1 -
Connectors for electronic equipment - Tests and measurements -- Part 4-1: Voltage stress tests - Test 4a: Voltage proof EN 60512-4-1 -
IEC 60512-5-1 -
Connectors for electronic equipment - Tests and measurements -- Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise EN 60512-5-1 -
IEC 60512-6-3 -
Connectors for electronic equipment - Tests and measurements -- Part 6-3: Dynamic stress tests - Test 6c: Shock EN 60512-6-3 -
IEC 60512-6-4 -
Connectors for electronic equipment - Tests and measurements -- Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) EN 60512-6-4 -
IEC 60512-9-1 -
Connectors for electronic equipment - Tests and measurements -- Part 9-1: Endurance tests - Test 9a: Mechanical operation EN 60512-9-1 -
IEC 60512-9-2 -
Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature EN 60512-9-2 -
IEC 60512-11-1 -
Electromechanical components for electronic equipment - Basic testing procedures and measuring methods -- Part 11: Climatic tests -- Section 1: Test 11a - Climatic sequence EN 60512-11-1 -
IEC 60512-11-4 -
Connectors for electronic equipment - Tests and measurements -- Part 11-4: Climatic tests - Test 11d: Rapid change of temperature EN 60512-11-4 -
IEC 60512-11-7 -
Connectors for electronic equipment - Tests and measurements -- Part 11- 7: Climatic tests - Test 11g: Flowing mixed gas corrosion test EN 60512-11-7 -
IEC 60512-11-9 -
Connectors for electronic equipment - Tests and measurements -- Part 11-9: Climatic tests - Test 11i: Dry heat EN 60512-11-9 -
SIST EN IEC 61076-2-111:2018



EN IEC 61076-2-111:2018 (E) 5 IEC 60512-11-10 -
Connectors for electronic equipment - Tests and measurements -- Part 11-10: Climatic tests - Test 11j: Cold EN 60512-11-10 -
IEC 60512-11-12 -
Connectors for electronic equipment - Tests and measurements -- Part 11-12: Climatic tests - Test 11m: Damp heat, cyclic EN 60512-11-12 -
IEC 60512-13-2 -
Connectors for electronic equipment - Tests and measurements -- Part 13-2: Mechanical operating tests - Test 13b: Insertion and withdrawal forces EN 60512-13-2 -
IEC 60512-13-5 -
Connectors for electronic equipment - Tests and measurements -- Part 13-5: Mechanical operating tests - Test 13e: Polarizing and keying method EN 60512-13-5 -
IEC 60512-16-5 -
Connectors for electronic equipment - Tests and measurements -- Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) EN 60512-16-5 -
IEC 60512-19-3 -
Electromechanical components for electronic equipment - Basic testing procedures and measuring methods -- Part 19: Chemical resistance tests -- Section 3: Test 19c - Fluid resistance EN 60512-19-3 -
IEC 60529 1989
Degrees of protection provided by enclosures (IP Code) EN 60529 1991
- -
+ corrigendum May 1993
+ A1 1999
+ A1 2000
+ A2 2013
+ A2 2013
IEC 60664-1 -
Insulation coordination for equipment within low-voltage systems -- Part 1: Principles, requirements and tests EN 60664-1 -
IEC 60999-1 -
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units -- Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) EN 60999-1 -
IEC 61076-1 2006
Connectors for electronic equipment - Product requirements -- Part 1: Generic specification EN 61076-1 2006
IEC 61984 -
Connectors - Safety requirements and tests EN 61984 -
IEC 62197-1 -
Connectors for electronic equipment - Quality assessment requirements -- Part 1: Generic specification EN 62197-1 -
ISO 1302 -
Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation EN ISO 1302 -
SIST EN IEC 61076-2-111:2018



EN IEC 61076-2-111:2018 (E) 6 ISO 11469 -
Plastics - Generic identification and marking of plastics products EN ISO 11469 -
SIST EN IEC 61076-2-111:2018



IEC 61076-2-111 Edition 1.0 2017-12 INTERNATIONAL STANDARD
Connectors for electrical and electronic equipment – Product requirements –
Part 2-111: Circular connectors – Detail specification for power connectors with M12 screw-locking
INTERNATIONAL ELECTROTECHNICAL COMMISSION
ICS 31.220.10
ISBN 978-2-8322-5109-6
® Registered trademark of the International Electrotechnical Commission ®
Warning! Make sure that you obtained this publication from an authorized distributor. SIST EN IEC 61076-2-111:2018



– 2 – IEC 61076-2-111:2017  IEC 2017 CONTENTS FOREWORD . 6 1 Scope . 9 2 Normative references . 9 3 Terms and definitions . 11 4 Technical information . 12 4.1 Systems of levels . 12 4.1.1 Performance levels . 12 4.1.2 Compatibility levels, according to IEC 61076-1 . 12 4.2 Classification into climatic categories . 12 4.3 Creepage and clearance distances . 12 4.4 Current-carrying capacity . 12 4.5 Marking . 13 4.6 Safety aspects . 13 5 Dimensional information . 13 5.1 General . 13 5.2 Survey of styles and variants . 14 5.2.1 General . 14 5.2.2 Contact terminations . 14 5.2.3 Number of contacts or contact cavities . 14 5.2.4 Fixed connectors . 15 5.2.5 Free connectors . 21 5.3 Interface dimensions . 28 5.3.1 E-coding . 28 5.3.2 F-coding . 31 5.3.3 K-coding . 35 5.3.4 L-coding . 39 5.3.5 M-coding . 43 5.3.6 S-coding . 47 5.3.7 T-coding . 50 5.4 Engagement (mating) information . 52 5.5 Gauges – Sizing gauges and retention force gauges . 54 6 Characteristics . 55 6.1 General . 55 6.2 Contact assignment and other definitions . 55 6.3 Classification into climatic category . 55 6.4 Electrical characteristics . 55 6.4.1 Creepage and clearance distances . 55 6.4.2 Voltage proof . 57 6.4.3 Rated voltage – Rated impulse voltage – Pollution degree . 57 6.4.4 Current-carrying capacity . 58 6.4.5 Contact resistance . 58 6.4.6 Insulation resistance. 59 6.4.7 Impedance . 59 6.5 Mechanical characteristics . 59 6.5.1 Mechanical operation . 59 6.5.2 Effectiveness of connector coupling devices . 59 SIST EN IEC 61076-2-111:2018



IEC 61076-2-111:2017  IEC 2017 – 3 – 6.5.3 Insertion and withdrawal forces . 59 6.5.4 Contact retention in insert . 59 6.5.5 Polarizing method . 60 6.6 Other characteristics . 60 6.6.1 Vibration (sinusoidal) . 60 6.6.2 Shock . 60 6.6.3 Degree of protection provided by enclosures (IP-code) . 60 6.6.4 Screen and shielding properties . 60 6.7 Enviromental aspects – Marking of insulation material (plastics) . 60 7 Test schedule . 61 7.1 General . 61 7.1.1 Overview . 61 7.1.2 Climatic category . 61 7.1.3 Creepage and clearance distances . 61 7.1.4 Arrangement for contact resistance measurements . 61 7.1.5 Arrangement for dynamic stress tests (vibration) . 62 7.1.6 Arrangement for testing static load; axial . 63 7.1.7 Wiring of specimens . 63 7.2 Test schedule . 63 7.2.1 Test group P – Preliminary . 63 7.2.2 Test group AP – Dynamic/ Climatic . 64 7.2.3 Test group BP – Mechanical endurance . 67 7.2.4 Test group CP – Electrical load . 68 7.2.5 Test group DP – Chemical resistivity . 69 7.2.6 Test group EP – Connection method tests . 69 Annex A (informative)
Diameter of the female connector body and orientation of coding . 70 A.1 Diameter of the female connector body . 70 A.2 Orientation of coding . 70
Figure 1 – Fixed connector, male contacts, mounting with thread M12 x 1, square flange 25 mm, front mounting . 15 Figure 2 – Fixed connector, male contacts, mounting with thread M12 x 1, square flange 20 mm, front mounting . 16 Figure 3 – Fixed connector, male contacts, mounting with thread M12 x 1, with wire ends, single hole mounting thread M16 x 1,5 . 16 Figure 4 – Fixed connector, male contacts, mounting with thread M12 x 1, with wire ends, single hole mounting thread M20 x 1,5 . 17 Figure 5 – Fixed connector, male contacts, mounting with thread M12 × 1 with wire ends, single hole mounting thread M16 × 1,5, mounting orientation . 17 Figure 6 – Fixed connector, male contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M20 × 1,5, mounting orientation . 18 Figure 7 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M16 × 1,5 . 18 Figure 8 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M20 × 1,5 . 19 Figure 9 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M16 × 1,5 . 19 Figure 10 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M20 × 1,5, mounting orientation . 20 SIST EN IEC 61076-2-111:2018



– 4 – IEC 61076-2-111:2017  IEC 2017 Figure 11 – Fixed connector, male contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M16 × 1,5, mounting orientation . 20 Figure 12 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire ends, single hole mounting thread M16 × 1,5, mounting orientation . 21 Figure 13 – Rewireable connector, male contacts, straight version, with locking nut . 22 Figure 14 – Rewireable connector, male contacts, right angled version, with locking nut . 23 Figure 15 – Non-rewireable connector, male contacts, straight version, with locking nut . 23 Figure 16 – Non-rewireable connector, male contacts, right angled version, with locking nut . 24 Figure 17 – Rewireable connector, female contacts, straight version, with locking nut . 25 Figure 18 – Rewireable connector, female contacts, right angled version, with locking nut
...................................................................................................................................... 26 Figure 19 – Non-rewireable connector, female contacts, straight version, with locking nut
...................................................................................................................................... 27 Figure 20 – Non-rewireable connector, female contacts, right angled version, with locking nut ............................................................................................................................ 28 Figure 21 – Male side E-coding ............................................................................................. 29 Figure 22 – Female side E-coding ......................................................................................... 30 Figure 23 – Contact position for E-coding front view ............................................................. 31 Figure 24 – Male side F-coding ............................................................................................. 32 Figure 25 – Female side F-coding ......................................................................................... 33 Figure 26 – Contact position for F-coding front view ............................................................. 34 Figure 27 – K-coding male side ............................................................................................. 35 Figure 28 – K-coding female side .......................................................................................... 37 Figure 29 – Contact position K-coding front view .................................................................. 38 Figure 30 – L-coding male side with one female contact ....................................................... 39 Figure 31 – L-coding female side with one male contact ....................................................... 41 Figure 32 – Contact position L-coding front view ................................................................... 42 Figure 33 – M-coding male site ............................................................................................. 43 Figure 34 – M-coding female side ......................................................................................... 45 Figure 35 – Contact position M-coding front view .................................................................. 46 Figure 36 – S-coding male side ............................................................................................. 47 Figure 37 – S-coding female side .......................................................................................... 49 Figure 38 – Contact position S-coding front view .................................................................. 49 Figure 39 – T-coding male side ............................................................................................. 50 Figure 40 – Contact position T-coding front view ................................................................... 52 Figure 41 – Engagement (mating) information ....................................................................... 52 Figure 42 – Gauge dimensions ............................................................................................. 54 Figure 43 – Contact resistance arrangement ......................................................................... 62 Figure 44 – Dynamic stress test arrangement ....................................................................... 63 Figure A.1 – Diameter of the female connector body ............................................................. 70 Figure A.2 – Orientation of cable outlet in relation to the coding – Free male connectors according to Table 4 ........................................................................................... 71
Table 1 – Ratings of connectors . 13 SIST EN IEC 61076-2-111:2018



IEC 61076-2-111:2017  IEC 2017 – 5 – Table 2 – Connector coding and number of contacts . 14 Table 3 – Styles of fixed connectors . 15 Table 4 – Styles of free connectors . 21 Table 5 – Dimensions of style JM, figure 13 . 22 Table 6 – Dimensions of style KM, figure 14 . 23 Table 7 – Dimensions of style LM, figure 15 . 24 Table 8 – Dimensions of style MM, figure 16 . 24 Table 9 – Dimensions of style JF, figure 17 . 25 Table 10 – Dimensions of style KF, figure 18 . 26 Table 11 – Dimensions of style LF, figure 19 . 27 Table 12 – Dimensions of style MF, figure 20 . 28 Table 13 – Dimensions for figure 21 . 29 Table 14 – Dimensions for Figure 22. 30 Table 15 – Dimensions for Figure 24. 32 Table 16 – Dimensions for Figure 25. 33 Table 17 – Dimensions for Figure 27. 36 Table 18 – Dimensions for Figure 28. 37 Table 19 – Dimensions for Figure 30. 40 Table 20 – Dimensions for Figure 31. 41 Table 21 – Dimensions for Figure 33. 44 Table 22 – Dimensions for Figure 34. 45 Table 23 – Dimensions for Figure 36. 48 Table 24 – D
...