Connectors for electronic equipment - Tests and measurements -- Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g

This part of IEC 60512 specifies the test methods for transmission performance for M12-style
connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they
meet the requirements of the detail specifications and of this standard.
NOTE 1 All figures show equipment for connectors according to IEC 61076-2-109 as an example.
The test methods provided herein are:
– insertion loss, test 29a;
– return loss, test 29b;
– near-end crosstalk (NEXT) test 29c;
– far-end crosstalk (FEXT), test 29d;
– transverse conversion loss (TCL), test 29f;
– transverse conversion transfer loss (TCTL), test 29g.
For the transfer impedance (ZT) test, see IEC 60512-26-100, test 26e.
For the coupling attenuation see ISO/IEC 11801.
All test methods apply for two and four pair connectors.
NOTE 2 All figures show schemes for four pair cabling and are also suitable for two pair cabling.

Steckverbinder für elektronische Einrichtungen – Mess- und Prüfverfahren – Teil 29-100: Signalintegritätsprüfungen bis 500 MHz an Steckverbindern M12 – Prüfungen 29a bis 29g

Connecteurs pour équipements électroniques - Essais et mesures - Partie 29-100: Essais d'intégrité des signaux jusqu'à 500 MHz sur les connecteurs de type M12 – Essais 29a à 29g

L'IEC 60512-29-100:2015 spécifie les méthodes d'essais pour les performances des transmissions pour les connecteurs de type M12 jusqu'à 500 MHz. Elle est également applicable aux essais réalisés sur des connecteurs à fréquences plus basses s'ils satisfont aux exigences des spécifications particulières et de la présente norme.
Les méthodes d'essai spécifiées ici sont:
- perte d'insertion, essai 29a;
- affaiblissement de réflexion, essai 29b;
- paradiaphonie (NEXT), essai 29c;
- télédiaphonie (FEXT), essai 29d;
- perte de conversion transverse (TCL), essai 29f;
- perte de transfert de conversion transverse (TCTL), essai 29g.  Pour l'essai d'impédance de transfert (ZT), voir l'IEC 60512-26-100, essai 26e. Pour l'affaiblissement de couplage, voir l'ISO/IEC 11801.
Toutes les figures représentent des principes pour des câblages de quatre paires
Mots-clés: Connecteurs, Intégrité des signaux, Connecteurs de type M12

Konektorji za elektronsko opremo - Preskusi in meritve - 29-100. del: Preskusi signalne celovitosti do 500 MHz na konektorjih M12 - Preskusi od 29a do 29g

Ta del standarda IEC 60512 določa preskusne metode za lastnosti prenosa na konektorjih M12 do 500 MHz. Prav tako je primeren za preskušanje konektorjev z nižjimi frekvencami, če ustrezajo zahtevam podrobnih specifikacij in tega standarda.
OPOMBA 1 Številke prikazujejo opremo za konektorje skladno s standardom IEC 61076-2-109 kot primer.
V nadaljevanju so podane naslednje preskusne metode:
– dodano dušenje, preskus 29a;
– povratno dušenje, preskus 29b;
– bližnji presluh (NEXT), preskus 29c;
– daljni presluh (FEXT), preskus 29d;
– prečno dušenje pretvorbe (TCL), preskus 29f;
– prečno dušenje pretvorbe prenosa (TCTL), preskus 29g.
Za preskus impedance prenosa (ZT) glejte IEC 60512-26-100, preskus 26e.
Za slabljenje stikov glejte ISO/IEC 11801.
Vse preskusne metode se uporabljajo za dvo- in štirižilne konektorje.
OPOMBA 2 Številke prikazujejo sheme za štirižilne kable in so ustrezne tudi za dvožilne kable.

General Information

Status
Published
Publication Date
09-Nov-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
29-Sep-2015
Due Date
04-Dec-2015
Completion Date
10-Nov-2015

Buy Standard

Standard
EN 60512-29-100:2015 - BARVE
English language
56 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60512-29-100:2015
01-december-2015
Konektorji za elektronsko opremo - Preskusi in meritve - 29-100. del: Preskusi
signalne celovitosti do 500 MHz na konektorjih M12 - Preskusi od 29a do 29g
Connectors for electronic equipment - Tests and measurements -- Part 29-100: Signal
integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g
Steckverbinder für elektronische Einrichtungen – Mess- und Prüfverfahren – Teil 29-100:
Signalintegritätsprüfungen bis 500 MHz an Steckverbindern M12 – Prüfungen 29a bis
29g
Ta slovenski standard je istoveten z: EN 60512-29-100:2015
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
SIST EN 60512-29-100:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60512-29-100:2015

---------------------- Page: 2 ----------------------

SIST EN 60512-29-100:2015


EUROPEAN STANDARD EN 60512-29-100

NORME EUROPÉENNE

EUROPÄISCHE NORM
September 2015
ICS 31.220.10

English Version
Connectors for electronic equipment - Tests and measurements
- Part 29-100: Signal integrity tests up to 500 MHz on M12 style
connectors - Tests 29a to 29g
(IEC 60512-29-100:2015)
Connecteurs pour équipements électroniques - Essais et Steckverbinder für elektronische Einrichtungen - Mess- und
mesures - Partie 29-100: Essais d'intégrité des signaux Prüfverfahren - Teil 29-100: Signalintegritätsprüfungen bis
jusqu'à 500 MHz sur les connecteurs de type M12 - Essais 500 MHz an Steckverbindern M12 - Prüfungen 29a bis 29g
29a à 29g (IEC 60512-29-100:2015)
(IEC 60512-29-100:2015)
This European Standard was approved by CENELEC on 2015-04-09. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 60512-29-100:2015 E

---------------------- Page: 3 ----------------------

SIST EN 60512-29-100:2015
EN 60512-29-100:2015
European foreword
The text of document 48B/2410/FDIS, future edition 1 of IEC 60512-29-100, prepared by
SC 48B "Connectors" of IEC/TC 48 "Electromechanical components and mechanical structures for
electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC
as EN 60512-29-100:2015.

The following dates are fixed:
• latest date by which the document has to be (dop) 2016-03-18
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2018-04-09
• latest date by which the national
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

Endorsement notice
The text of the International Standard IEC 60512-29-100:2015 was approved by CENELEC as a
European Standard without any modification.
IEC 60512-27-100 NOTE Harmonized as EN 60512-27-100.

2

---------------------- Page: 4 ----------------------

SIST EN 60512-29-100:2015
 EN 60512-29-100:2015

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant

EN/HD applies.

NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year

IEC 60050 series International Electrotechnical Vocabulary - series
IEC 60512-1 -  Connectors for electronic equipment - EN 60512-1 -
Tests and measurements -- Part 1:
General
IEC 60512-26-100 -  Connectors for electronic equipment - EN 60512-26-100 -
Tests and measurements -- Part 26-100:
Measurement setup, test and reference
arrangements and measurements for
connectors according to IEC 60603-7 -
Tests 26a to 26g
IEC 61076-1 -  Connectors for electronic equipment - EN 61076-1 -
Product requirements -- Part 1: Generic
specification
IEC 61076-2-101 -  Connectors for electronic equipment - EN 61076-2-101 -
Product requirements -- Part 2-101:
Circular connectors - Detail specification
for M12 connectors with screw-locking
IEC 61076-2-109 -  Connectors for electronic equipment - EN 61076-2-109 -
Product requirements -- Part 2-109:
Circular connectors - Detail specification
for connectors with m 12 x 1 screw-locking,
for data transmissions with frequencies up
to 500 MHz
IEC 61169-16 -  Radio-frequency connectors -- Part 16: RF EN 61169-16 -
coaxial connectors with inner diameter of
outer conductor 7 mm (0,276 in) with screw
coupling - Characteristic impedance 50
ohms (75 ohms) (Type N)
ISO/IEC 11801 -  Information technology - Generic cabling - -
for customer premises
EN 50289-1-14 -  Communication cables - Specifications for - -
test methods - Part 1-14: Electrical test
methods - Coupling attenuation or
screening attenuation of connecting
hardware
ITU-T -  Transmission aspects of unbalance about - -
Recommendation earth
G.117
ITU-T -  Measuring arrangements to assess the - -
Recommendation degree of unbalance about earth
O.9
3

---------------------- Page: 5 ----------------------

SIST EN 60512-29-100:2015
EN 60512-29-100:2015

4

---------------------- Page: 6 ----------------------

SIST EN 60512-29-100:2015




IEC 60512-29-100

®


Edition 1.0 2015-03




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Connectors for electronic equipment – Tests and measurements –

Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors –

Tests 29a to 29g




Connecteurs pour équipements électroniques – Essais et mesures –

Partie 29-100: Essais d'intégrité des signaux jusqu'à 500 MHz sur les


connecteurs de type M12 – Essais 29a à 29g













INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 31.220.10 ISBN 978-2-8322-2306-2



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 60512-29-100:2015
– 2 – IEC 60512-29-100:2015 © IEC 2015
CONTENTS
FOREWORD . 6
1 Scope and object . 8
2 Normative references . 8
3 Terms, definitions and abbreviations . 9
3.1 Terms and definitions . 9
3.2 Abbreviations . 9
4 Overall test arrangement . 10
4.1 Test instrumentation . 10
4.2 Coaxial cables and interconnect for network analysers . 11
4.3 Measurement precautions . 11
4.4 Reference components for calibration . 13
4.4.1 Reference loads for calibration . 13
4.5 Termination loads for termination of conductor pairs . 14
4.5.1 Differential mode . 14
4.5.2 Balun terminations . 14
4.5.3 Termination types . 15
4.6 Termination of screens . 15
4.7 Test specimen and reference planes . 15
4.7.1 General . 15
4.7.2 Interconnections between device under test (DUT) and the calibration
plane . 15
4.8 Termination of balun . 17
4.8.1 General requirements . 17
4.8.2 Centre tap connected to ground . 17
4.8.3 Centre tap open . 18
4.9 Sequence for calibration and measurement . 18
5 Connector measurement up to 100 MHz and 500 MHz . 22
5.1 General . 22
5.2 Insertion loss, Test 29a . 22
5.2.1 Object . 22
5.2.2 Connector with male or female contacts for insertion loss . 23
5.2.3 Test method . 23
5.2.4 Test set-up . 23
5.2.5 Procedure . 23
5.2.6 Test report . 24
5.2.7 Accuracy . 24
5.3 Return loss, Test 29b . 24
5.3.1 Object . 24
5.3.2 Connector with male or female contacts for return loss . 24
5.3.3 Test method . 24
5.3.4 Test set-up . 24
5.3.5 Procedure . 25
5.3.6 Test report . 25
5.3.7 Accuracy . 25
5.4 Near-end crosstalk (NEXT), Test 29c . 26
5.4.1 Object . 26

---------------------- Page: 8 ----------------------

SIST EN 60512-29-100:2015
IEC 60512-29-100:2015 © IEC 2015 – 3 –
5.4.2 Connector with male or female contacts for NEXT . 26
5.4.3 Test method . 26
5.4.4 Test set-up . 26
5.4.5 Procedure . 27
5.4.6 Test report . 28
5.4.7 Accuracy . 28
5.5 Far-end crosstalk (FEXT), Test 29d . 28
5.5.1 Object . 28
5.5.2 Connector with male or female contacts for FEXT . 28
5.5.3 Test method . 28
5.5.4 Test set-up . 28
5.5.5 Procedure . 29
5.5.6 Test report . 30
5.5.7 Accuracy . 30
5.6 Transfer impedance (ZT), Test 29e . 30
5.7 Transverse conversion loss (TCL), Test 29f . 30
5.7.1 Object . 30
5.7.2 Connector with male or female contacts for TCL . 30
5.7.3 Test method . 30
5.7.4 Test set-up . 30
5.7.5 Procedure . 31
5.7.6 Test report . 33
5.7.7 Accuracy . 34
5.8 Transverse conversion transfer loss (TCTL), Test 29g . 34
5.8.1 Object . 34
5.8.2 Connector with male or female contacts for TCTL . 34
5.8.3 Test method . 34
5.8.4 Test set-up . 34
5.8.5 Procedure . 35
5.8.6 Test report . 35
5.8.7 Accuracy . 35
5.9 Coupling attenuation . 35
6 Construction and qualification of direct fixtures (DFP and DFJ) . 35
6.1 General . 35
6.2 Direct fixtures for DUT testing . 36
6.2.1 Requirements for direct fixture up to 100 MHz . 36
6.2.2 Requirements for direct fixture up to 500 MHz . 37
Annex A (normative) Impedance controlled measurement fixture . 39
A.1 General . 39
A.2 Load . 40
A.3 Additional components for connection to a network analyzer . 42
A.4 Direct fixture . 44
A.5 Connecting hardware measurement 1 configuration . 47
A.6 DUT connections using header PCB assemblies . 47
Annex B (informative) Reference source . 48
B.1 Test fixture components . 48
Annex C (informative) Related connectors . 49
Annex D (informative) Interface to test fixtures . 50

---------------------- Page: 9 ----------------------

SIST EN 60512-29-100:2015
– 4 – IEC 60512-29-100:2015 © IEC 2015
Bibliography . 52

Figure 1 – Measurement strategies . 10
Figure 2 – 180° hybrid used as a balun . 11
Figure 3 – Measurement configurations for test balun qualification . 13
Figure 4 – Calibration of reference loads . 14
Figure 5 – Resistor termination networks . 14
Figure 6 – Definition of reference planes . 15
Figure 7 – Balanced attenuator for balun centre tap grounded . 17
Figure 8 – Balanced attenuator for balun centre tap open . 18
Figure 9 – Open calibration . 18
Figure 10 – Short calibration . 19
Figure 11 – Load calibration. 19
Figure 12 – Thru calibration . 20
Figure 13 – Measurement of RL and NEXT on the DUT . 21
Figure 14 – Measurement of IL and FEXT on the DUT . 22
Figure 15 – Measuring set-up . 23
Figure 16 – Return loss measurement . 25
Figure 17 – NEXT measurement . 27
Figure 18 – FEXT measurement for differential and common mode terminations . 29
Figure 19 – TCL measurement . 31
Figure 20 – Coaxial lead attenuation calibration . 31
Figure 21 – Back to back balun insertion loss measurement . 32
Figure 22 – Configuration for balun common mode insertion loss calibration . 32
Figure 23 – Schematic for balun common mode insertion loss calibration . 33
Figure 24 – TCTL measurement . 34
Figure 25 – Reference planes . 36
Figure 26 – Direct fixture M12, d-code mating face . 37
Figure 27 – Direct fixture M12, d-code . 37
Figure 28 – Direct fixture M12, x-code mating face . 38
Figure 29 – Direct fixture M12, x-code . 38
Figure A.1 – Test head assembly M12, d-code with baluns attached . 39
Figure A.2 – Test head assembly M12, x-code with baluns attached . 40
Figure A.3 – Test head assembly M12 mated with the load M12 . 41
Figure A.4 – Balun test fixture with the load M12 . 41
Figure A.5 – Load M12, x-code . 42
Figure A.6 – Load M12, d-code . 42
Figure A.7 – Test head showing shielding between baluns . 43
Figure A.8 – Balun test fixture assembly . 44
Figure A.9 – Direct fixture M12, d-code (DFJ) for DUT with male contacts . 45
Figure A.10 – Direct fixture M12, d-code (DFJ) for DUT with male contacts . 45
Figure A.11 – Direct fixture M12, x-code (DFJ) for DUT with male contacts . 46
Figure A.12 – Direct fixture M12, x-code (DFJ) for DUT with male contacts – Cross-cut . 46

---------------------- Page: 10 ----------------------

SIST EN 60512-29-100:2015
IEC 60512-29-100:2015 © IEC 2015 – 5 –
Figure A.13 – Exploded assembly of the direct fixture (DFJ) . 47
Figure A.14 – Example of a connecting hardware measurement configuration . 47
Figure D.1 – Test balun interface pattern . 50
Figure D.2 – Example pin and socket dimension . 51

Table 1 – Test balun performance characteristics up to 500 MHz . 12
Table 2 – Test balun performance characteristics up to 100 MHz . 12
Table 3 – Interconnection return loss . 16
Table 4 – Uncertainty band of return loss measurement at frequencies below 100 MHz . 26
Table 5 – Uncertainty band of return loss measurement at frequencies above 100 MHz . 26
Table 6 – Direct fixture M12, performance up to 100 MHz . 37
Table 7 – Direct fixture M12, performance up to 500 MHz . 38
Table A.1 – Load M12, performance up to 500 MHz . 42
Table A.2 – Load M12, performance up to 100 MHz . 42
Table C.1 – Related connectors . 49

---------------------- Page: 11 ----------------------

SIST EN 60512-29-100:2015
– 6 – IEC 60512-29-100:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –

Part 29-100: Signal integrity tests up
to 500 MHz on M12 style connectors –
Tests 29a to 29g

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shal
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.