SIGNIFICANCE AND USE
5.1 The Primary Function of a Tennis Court Perimeter Enclosure is to keep tennis balls in and uninvited traffic out. It also serves as a barrier to prevent players from colliding with fixed objects and spectators. It prevents players from running onto irregular or slippery surfaces or into dangerous adjacent areas. Enclosures need to respond to secondary functional requirements, including; spectator viewing, screening the court from wind and visual distractions outside the court, and be as open and welcoming as security considerations permit. Tennis courts were once surrounded by a 10 ft (3050 mm) to 12 ft (3660 mm) high fence. In cases where security or dangerous adjacent conditions are an issue, this type of enclosure is still popular, but in most cases, tennis fences are a variety of heights and can accommodate lights, shade shelters, gates for players and maintenance, and can have completely open portions of the perimeter that lead to decks, grandstands or landscaping.  
5.2 The Intended Use of This Guide is to identify the specific functions and qualities desired of a tennis enclosure and offer recommendations on how to achieve them with a chain link fence, or other enclosure, for different type of tennis courts. Although this standard is focused on chain link fencing that makes up the majority of tennis enclosures, many of the recommendations are applicable to other traditional and new fencing options for tennis court enclosures that are available on the market. This Standard is intended primarily to guide those responsible for, or concerned with, the layout and design of perimeter enclosures for both private and public tennis courts, and where other standards may not apply.
SCOPE
1.1 This guide provides design recommendations that promote quality construction and aim to reduced maintenance of tennis court enclosures. This guide informs those interested in the design, layout and maintenance of tennis court fencing on the many details and features of such enclosures. This standard describes various types of fence fabric and framework material that are available and refers to other useful resource material for designing better-quality tennis court enclosures.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    7 pages
    English language

ABSTRACT
This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. Any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking shall be discussed. Other materials present in skatepark facilities include steel reinforcing and synthetic fibers. Physical properties such as concrete finish, surface flatness, and levelness shall be considered. In addition, expansion joints, filled control joints, and tooled control joints shall be discussed. Expansion joints should be placed where they are least likely to interfere with a wheel. Careful consideration to expansion joints location must be given, using the flow of skaters as critical design criteria. Size of control joint is not important. It must be a rigid control joint filler, which must be flush with the skating surface and close the joint completely. Also, joints should be placed where they are least likely to interfere with skate wheels, and a cut control joint is not possible. The placement of concrete on sloped radii or any areas incorporating a change in elevation is critical to the stability of the exposed steel material or concrete coping. The difficulty of achieving proper consolidation around the steel material and their reinforced attachments through the use of standard air removal consolidation techniques can lead to slumping and the creation of an air pocket around the steel material, which may not be visible during construction and may result in concrete failure on the riding surface. Skatepark signage, free standing or fixed fence, shall be provided and shall indicate the following: adult supervision of minors is or is not present; owner-operator emergency telephone numbers; emergency telephone numbers for medical, ambulance, and police; applicable regulations regarding the use of safety gear; presence of inherent risk in the participitation of skatepark activities; and drunk or users under the influence of drugs shall not participate in any skatepark activities.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. This guide pertains to any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.  
1.2 Tolerance: General Measures, Tolerances, and Conversions—General dimensional tolerances for this guide (unless otherwise noted) follow. These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.    
Dimension  
Tolerance  
X in. or ft  
±0.5 in.  
X.X in.  
±0.05 in.  
X.XX in.  
±0.005 in.  
1.3 The values stated in inch-pound units are to be regarded as standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    4 pages
    English language
  • Guide
    4 pages
    English language

ABSTRACT
This guide establishes the safety, performance and maintenance requirements pertaining to above-ground (indoor/outdoor), public-use skatepark facilities and any elements included therein that are intended to be used in the performance of the sports including skateboarding, inline skating, and BMX biking. The skatepark elements covered here are guardrails (including return guardrails and adjoining resting deck guardrails), protective edging/surfaces, riding surfaces, copings, approaches/thresholds, stairs, and portable and stand-alone elements. Items such as fencing, lighting, and operational structures are not addressed here.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to public skatepark facilities and any element included therein. These guidelines pertain to any elements intended to be used in the performance of the sports including skateboarding, inline skating, and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.  
1.2 This guide applies to above-ground (indoor/outdoor) skatepark elements, intended for recreational use.  
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.4 Tolerances – General Measures, Tolerances, and Conversions—The general dimensional tolerances for this specification (unless otherwise noted) are as follows:    
Dimension  
Tolerance  
X in. or ft  
±0.5 in. or ft  
X.X in. or ft  
±0.05 in. or ft  
X.XX in. or ft  
±0.005 in. or ft
Note 1: These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 2: The conversion factor from inch-pound to SI units is 1 in. = 25.4 mm, and 1 lb = 0.45359 kg.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    6 pages
    English language
  • Guide
    6 pages
    English language

ABSTRACT
This guide deals with the provisions for consistent safety considerations in the design and construction of new roller hockey rinks in order to reduce potential safety hazards. It is projected to standardize game conditions; establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials; and applies to the development of new arenas and to existing facilities that will be renovated. This guide takes into consideration that most ice hockey rinks with concrete surfaces can be acceptable for roller hockey. However, dasher boards must meet criteria respective of the specific activity. Facilities designed and constructed for roller hockey may not be acceptable for ice hockey use. Included in this guide are the structures and environment, player's bench and box, penalty benches and box, off-rink official's bench/box, signal and timing devices, dressing rooms, nets, rink floor design, illumination, emergency medical care, and signage.
SCOPE
1.1 This guide covers the provisions for consistent safety considerations in the design and construction of new roller hockey rinks in order to reduce potential safety hazards. It is intended to standardize game conditions and establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials.  
1.2 This guide should be taken into consideration by architects, designers, engineers, construction contractors, and appropriate inspectors who may be involved in the design and construction of new roller hockey rinks. This guide applies to the development of new arenas and to existing facilities that will be renovated.  
1.3 This guide takes into consideration that most ice hockey rinks with concrete surfaces can be acceptable for roller hockey. However, dasher boards must meet criteria respective of the specific activity. Facilities designed and constructed for roller hockey may not be acceptable for ice hockey use.  
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    5 pages
    English language

SCOPE
1.1 This guide covers safety and performance guidelines pertaining to public skatepark facilities and any element included therein. These guidelines pertain to any elements intended to be used in the performance of the sports including skateboarding, inline skating, and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.  
1.2 This guide applies to above-ground (indoor/outdoor) skatepark elements, intended for recreational use.  
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.4 Tolerances – General Measures, Tolerances, and Conversions—The general dimensional tolerances for this specification (unless otherwise noted) are as follows:    
Dimension  
Tolerance  
X in. or ft  
±0.5 in. or ft  
X.X in. or ft  
±0.05 in. or ft  
X.XX in. or ft  
±0.005 in. or ft
Note 1: These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 2: The conversion factor from inch-pound to SI units is 1 in. = 25.4 mm, and 1 lb = 0.45359 kg.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    6 pages
    English language
  • Guide
    6 pages
    English language

ABSTRACT
This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. Any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking shall be discussed. Other materials present in skatepark facilities include steel reinforcing and synthetic fibers. Physical properties such as concrete finish, surface flatness, and levelness shall be considered. In addition, expansion joints, filled control joints, and tooled control joints shall be discussed. Expansion joints should be placed where they are least likely to interfere with a wheel. Careful consideration to expansion joints location must be given, using the flow of skaters as critical design criteria. Size of control joint is not important. It must be a rigid control joint filler, which must be flush with the skating surface and close the joint completely. Also, joints should be placed where they are least likely to interfere with skate wheels, and a cut control joint is not possible. The placement of concrete on sloped radii or any areas incorporating a change in elevation is critical to the stability of the exposed steel material or concrete coping. The difficulty of achieving proper consolidation around the steel material and their reinforced attachments through the use of standard air removal consolidation techniques can lead to slumping and the creation of an air pocket around the steel material, which may not be visible during construction and may result in concrete failure on the riding surface. Skatepark signage, free standing or fixed fence, shall be provided and shall indicate the following: adult supervision of minors is or is not present; owner-operator emergency telephone numbers; emergency telephone numbers for medical, ambulance, and police; applicable regulations regarding the use of safety gear; presence of inherent risk in the participitation of skatepark activities; and drunk or users under the influence of drugs shall not participate in any skatepark activities.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. This guide pertains to any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.  
1.2 Tolerance: General Measures, Tolerances, and Conversions—General dimensional tolerances for this guide (unless otherwise noted) follow. These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.    
Dimension  
Tolerance  
X in. or ft  
±0.5 in.  
X.X in.  
±0.05 in.  
X.XX in.  
±0.005 in.  
1.3 The values stated in inch-pound units are to be regarded as standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    4 pages
    English language
  • Guide
    4 pages
    English language

ABSTRACT
This guide deals with the provisions for consistent safety considerations in the design and construction of new roller hockey rinks in order to reduce potential safety hazards. It is projected to standardize game conditions; establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials; and applies to the development of new arenas and to existing facilities that will be renovated. This guide takes into consideration that most ice hockey rinks with concrete surfaces can be acceptable for roller hockey. However, dasher boards must meet criteria respective of the specific activity. Facilities designed and constructed for roller hockey may not be acceptable for ice hockey use. Included in this guide are the structures and environment, player's bench and box, penalty benches and box, off-rink official's bench/box, signal and timing devices, dressing rooms, nets, rink floor design, illumination, emergency medical care, and signage.
SCOPE
1.1 This guide covers the provisions for consistent safety considerations in the design and construction of new roller hockey rinks in order to reduce potential safety hazards. It is intended to standardize game conditions and establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials.
1.2 This guide should be taken into consideration by architects, designers, engineers, construction contractors, and appropriate inspectors who may be involved in the design and construction of new roller hockey rinks. This guide applies to the development of new arenas and to existing facilities that will be renovated.
1.3 This guide takes into consideration that most ice hockey rinks with concrete surfaces can be acceptable for roller hockey. However, dasher boards must meet criteria respective of the specific activity. Facilities designed and constructed for roller hockey may not be acceptable for ice hockey use.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This guide covers the provisions for consistent safety considerations in the design and construction of new roller hockey rinks in order to reduce potential safety hazards. It is intended to standardize game conditions and establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials.
Formerly under the jurisdiction of Committee F08 on Sports Equipment, Playing Surfaces, and Facilities, this guide was withdrawn in January 2014 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

  • Guide
    4 pages
    English language

ABSTRACT
This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. Any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking shall be discussed. Other materials present in skatepark facilities include steel reinforcing and synthetic fibers. Physical properties such as concrete finish, surface flatness, and levelness shall be considered. In addition, expansion joints, filled control joints, and tooled control joints shall be discussed. Expansion joints should be placed where they are least likely to interfere with a wheel. Careful consideration to expansion joints location must be given, using the flow of skaters as critical design criteria. Size of control joint is not important. It must be a rigid control joint filler, which must be flush with the skating surface and close the joint completely. Also, joints should be placed where they are least likely to interfere with skate wheels, and a cut control joint is not possible. The placement of concrete on sloped radii or any areas incorporating a change in elevation is critical to the stability of the exposed steel material or concrete coping. The difficulty of achieving proper consolidation around the steel material and their reinforced attachments through the use of standard air removal consolidation techniques can lead to slumping and the creation of an air pocket around the steel material, which may not be visible during construction and may result in concrete failure on the riding surface. Skatepark signage, free standing or fixed fence, shall be provided and shall indicate the following: adult supervision of minors is or is not present; owner-operator emergency telephone numbers; emergency telephone numbers for medical, ambulance, and police; applicable regulations regarding the use of safety gear; presence of inherent risk in the participitation of skatepark activities; and drunk or users under the influence of drugs shall not participate in any skatepark activities.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. This guide pertains to any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.
1.2 Tolerance: General Measures, Tolerances, and Conversions—General dimensional tolerances for this guide (unless otherwise noted) follow. These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used. Dimension Tolerance X in. or ft±0.5 in. X.X in.±0.05 in. X.XX in.±0.005 in.
1.3 The values stated in inch-pound units are to be regarded as standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Guide
    4 pages
    English language

ABSTRACT
This guide establishes the safety, performance and maintenance requirements pertaining to above-ground (indoor/outdoor), public-use skatepark facilities and any elements included therein that are intended to be used in the performance of the sports including skateboarding, inline skating, and BMX biking. The skatepark elements covered here are guardrails (including return guardrails and adjoining resting deck guardrails), protective edging/surfaces, riding surfaces, copings, approaches/thresholds, stairs, and portable and stand-alone elements. Items such as fencing, lighting, and operational structures are not addressed here.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to public skatepark facilities and any element included therein. These guidelines pertain to any elements intended to be used in the performance of the sports including skateboarding, inline skating, and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.
1.2 This guide applies to above-ground (indoor/outdoor) skatepark elements, intended for recreational use.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 Tolerances – General Measures, Tolerances, and Conversions—The general dimensional tolerances for this specification (unless otherwise noted) are as follows: DimensionTolerance X in. or ft±0.5 in. or ft X.X in. or ft±0.05 in. or ft X.XX in. or ft±0.005 in. or ft
Note 1—These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 2—The conversion factor from inch-pound to SI units is 1 in. = 25.4 mm, and 1 lb = 0.45359 kg.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Guide
    6 pages
    English language

ABSTRACT
This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. Any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking shall be discussed. Other materials present in skatepark facilities include steel reinforcing and synthetic fibers. Physical properties such as concrete finish, surface flatness, and levelness shall be considered. In addition, expansion joints, filled control joints, and tooled control joints shall be discussed. Expansion joints should be placed where they are least likely to interfere with a wheel. Careful consideration to expansion joints location must be given, using the flow of skaters as critical design criteria. Size of control joint is not important. It must be a rigid control joint filler, which must be flush with the skating surface and close the joint completely. Also, joints should be placed where they are least likely to interfere with skate wheels, and a cut control joint is not possible. The placement of concrete on sloped radii or any areas incorporating a change in elevation is critical to the stability of the exposed steel material or concrete coping. The difficulty of achieving proper consolidation around the steel material and their reinforced attachments through the use of standard air removal consolidation techniques can lead to slumping and the creation of an air pocket around the steel material, which may not be visible during construction and may result in concrete failure on the riding surface. Skatepark signage, free standing or fixed fence, shall be provided and shall indicate the following: adult supervision of minors is or is not present; owner-operator emergency telephone numbers; emergency telephone numbers for medical, ambulance, and police; applicable regulations regarding the use of safety gear; presence of inherent risk in the participitation of skatepark activities; and drunk or users under the influence of drugs shall not participate in any skatepark activities.
SCOPE
1.1 This guide covers safety and performance guidelines pertaining to in-ground skatepark facilities built primarily out of concrete and other designed materials. This guide pertains to any concrete materials and other designed materials intended to be used in the performance of the sports including skateboarding, inline skating and BMX biking. Items such as fencing, lighting, and operational structures are not intended to be a part of this guide.
1.2 Tolerance: General Measures, Tolerances, and Conversions General dimensional tolerances for this guide (unless otherwise noted) follow. These tolerances still apply to a dimension even when terms like greater than, less than, minimum, or maximum are used.Dimension ToleranceX in. or ft0.5 in.X.X in.0.05 in.X.XX in.0.005 in.
1.3 The values stated in inch-pound units are to be regarded as standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Guide
    4 pages
    English language

SCOPE
1.1 The intent of this guide is to provide consistent safety considerations in the design specifications and construction of new ice hockey playing facilities. It is intended to standardize facility conditions and establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players, game officials, and spectators.
1.2 This guide should be taken into consideration by architects, planners, engineers, construction companies, construction contractors, and appropriate inspectors who may be involved in the design and construction of new ice hockey playing facilities. This guide applies to the construction and development of new ice hockey playing facilities.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in SI units are for information only.

  • Guide
    10 pages
    English language

SCOPE
1.1 The intent of this guide is to provide consistent safety considerations in the design and construction of new ice hockey rinks in order to reduce potential safety hazards. It is intended to standardize game conditions and establish guidelines that will provide a level of conformity for the purpose of competition and reduce potential hazards to players and game officials.  
1.2 This guide should be taken into consideration by architects, designers, engineers, construction companies, construction contractors, and appropriate inspectors who may be involved in the design and construction of new ice hockey rinks. This guide applies to the development of new arenas and to existing facilities that will be renovated.

  • Guide
    8 pages
    English language

SCOPE
1.1 The intent of this guide is to provide consistent considerations for the design, construction, and retrofitting of ice skating and ice hockey playing facilities. It is intended to establish guidelines that will provide a level of functionality for recreational skating, conformity for the purpose of competition and reduce potential hazards to skaters, players, game officials, spectators, and employees.  
1.2 This guide should be taken into consideration by owners/operators, architects, planners, engineers, equipment manufacturers, construction companies, construction contractors, and appropriate inspectors who may be involved in the design and construction of new ice skating/hockey playing facilities. Whenever possible, environmental sustainability and energy efficiency should be taken into consideration in the planning and design of facilities. This guide applies only to the construction and development of new ice skating/hockey playing facilities. Portions, however, may be useful for renovation projects, such as, replacing worn out dasherboards.  
1.3 Every arena is unique in material, architecture, and engineering, and therefore will require technical review. This guide is not meant to provide an architectural prototype, but is a guide to set forth measures for the development of safer ice arena venues.  
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in SI units are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
The intent of this guide is to provide consistent considerations for the design, construction, and retrofitting of ice skating and ice hockey playing facilities. It is intended to establish guidelines that will provide a level of functionality for recreational skating, conformity for the purpose of competition and reduce potential hazards to skaters, players, game officials, spectators, and employees.
Formerly under the jurisdiction of Committee F08 on Sports Equipment, Playing Surfaces, and Facilities, this guide was withdrawn in July 2022 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

  • Guide
    12 pages
    English language

ABSTRACT
This guide for the layout of the ice rink/arenas includes guidelines for developing an artificial indoor ice rink/arena. This guide describes systematic procedures and criteria for the development of the arena's appurtenant facilities. A description of several appurtenant facilities utilized in ice rink/arenas is included within the guide as examples of those that should be considered. The guidelines in the design and selection of ice rink/arena dehumidification equipment are presented in details. Many factors, including climate, can influence the selection of ice rink systems and other components. The ice rink system and other interior and exterior components should be thoroughly designed by an experienced, registered professional engineer or architect. The ice arena may include space for the ice rink, mechanical room, entry arena, participant changing areas, spectator, and administrative areas. The ice rink/arena structure shall meet minimum insulation U values and R ratings. The fire capacity of the building, classification of use, and intensity of patron use should be considered in the design process. Gasoline, propane, or natural gas may be used in the facility, and storage systems for these materials should be included into facility design and stipulated by state and local codes.
SCOPE
1.1 This guide for the layout of the ice rink/arenas includes guidelines for developing an artificial indoor ice rink/arena. This guide describes systematic procedures and criteria for the development of the arena's appurtenant facilities. A description of several appurtenant facilities utilized in ice rink/arenas is included within the guide as examples of those that should be considered.
1.2 This guide addresses only those phases of a project related to the selection design, specification, and installation procedures. Every arena is unique in material, architecture, and engineering, and therefore will require technical review. This guide is not meant to provide an architectural prototype, but is a guide to set forth measures for the development of safer ice arena venues.
1.3 This guide shall only be used by architects, designers, registered engineers, construction contractors, owners/operators, and appropriate inspectors who are involved in the design and construction of new ice arena venues.
1.4 This guide is pertinent to the support facilities of a multi-use ice arena.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This guide for the layout of the ice rink/arenas includes guidelines for developing an artificial indoor ice rink/arena. This guide describes systematic procedures and criteria for the development of the arena's appurtenant facilities. A description of several appurtenant facilities utilized in ice rink/arenas is included within the guide as examples of those that should be considered.
Formerly under the jurisdiction of Committee F08 on Sports Equipment, Playing Surfaces, and Facilities, this guide was withdrawn in January 2016 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

  • Guide
    5 pages
    English language

Frequently Asked Questions

F08.66 is a Technical Committee within ASTM International. It is named "Sports Facilities". This committee has published 14 standards.

F08.66 develops ASTM standards in the area of Information technology. Currently, there are 14 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...