CEN/TC 79/SC 3 - Facepieces
Facepieces as main components for RPD, filtering facepieces and filtering devices without breathing assitance.
Facepieces
Facepieces as main components for RPD, filtering facepieces and filtering devices without breathing assitance.
General Information
This European Standard is applicable to centre threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to self-contained compressed air breathing apparatus designed as positive pressure breathing apparatus. This European Standard specifies a thread connection, M 45 x 3, which may optionally be used for facepieces for positive pressure breathing apparatus. This European Standard does not apply to negative pressure breathing apparatus, to closed-circuit breathing apparatus or to diving equipment.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies minimum requirements for full face masks for respiratory protective devices. Full face masks for diving apparatus are not included in the scope of this European Standard. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to standard threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements, test methods and marking requirements for half masks (re-usable) without inhalation valves and with separable filters (designed for a maximum of single shift use) to protect against gases or gases and particles or particles only. It does not cover devices designed for use in circumstances where there is or might be an oxygen deficiency (oxygen less than 17 % by volume) or for escape purposes. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Modification in Clause 6, 8.9.1.1 and 8.9.1.2 as well as Figure 11 and Table 4
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
This European Standard specifies the performance requirements, test methods and marking requirements for valved filtering half masks incorporating either gas or combined filters as respiratory protective devices except for escape purposes. It does not cover gas filtering half masks which do not have valves or are fitted only with exhalation valves. It does not cover devices designed for use in circumstances where there is or might be an oxygen deficiency (oxygen less than a volume fraction of 17 %).
Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies minimum requirements for filtering half masks as respiratory protective devices to protect against particles except for escape purposes. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies filtering devices with hood for personal escape from particular matter, carbon monoxide and other toxic gases produced by fire. It specifies minimum requirements for this device which is for single use. It does not cover devices desiged for use in circumstances where there is or might be an oxgygen deficiency (oxygen less than 17 % by volume). Two types of devices are specified; namely, those designed to be carried on the person and those designed to be stored. This standards specifies devices primarily designed for adult users. Some devices may not be suitable for children. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies minimum requirements for filtering half masks as respiratory protective devices against particles except for escape purposes. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies minimum requirements for powered particle filtering devices incorporating helmets or hoods used as respiratory protective devices. It does not cover devices designed for use in circumstances where there is or might be an oxygen deficiency (oxygen less than 17 % by volume). It also does not cover respiratory protective devices designed for escape purposes. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies full face masks for special use like fire fighting, mining. It specifies minimum requirements for full face masks for use as part of respiratory protective devices for special use. Laboratory and practical performance tests are included for the assessment of compliance with the requirements.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day