CLC/TC 20/WG 11 - Harmonisation of joints, accessories and terminations of electric cables
Harmonisation of joints, accessories and terminations of electric cables
General Information
This document specifies the test methods and requirements of tests for fingerprinting (as defined in 3.9) of solvent-free polymerizable, reacting resinous compound intended to be used for electrical insulation and/or mechanical protection in cable accessories covered by EN 50393, HD 629.1 and HD 629.2, for low and medium voltage up to 20,8/36 (42) kV. Fingerprinting testing of materials does not have a mandatory link to type testing of accessories. It is regarded as stand-alone tests, but it can be carried out in combination with the accessory type tests. NOTE Information on health and safety is given in Annex A.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies performance requirements for type tests for cable accessories for use on extruded insulation power cables as specified in HD 620 or other relevant cable standards. The accessories covered by this standard are indoor and outdoor terminations of all designs, straight-joints, branch-joints, stop ends and loop joints of all designs, suitable for use underground, indoors or outdoors, and screened or unscreened plug-in type or bolted-type separable connectors. Voltage rating covers 3,6/6 kV up to and including 20,8/36 kV
- Standardization document44 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 5 applies to the connections described in prEN 50483 4, including branch connectors, Insulation Piercing Connectors (IPC), pre-insulated lugs (terminals) and through pre-insulated connectors (sleeves). Two classes of connectors are covered by this document: - Class A: These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors will be suitable for the majority of applications. - Class B: These are connectors for networks in which overloads or short-circuits are rapidly cleared by the operation of protection devices. Depending on their application, the connectors are subjected to heat cycles and short-circuit current tests. Class A: the connectors are subjected to heat cycles and short-circuit current tests. Class B: the connectors are subjected to heat cycles only. The object of this Part 5 is to define the heating cycles test methods and requirements which apply to compression through connectors, insulation piercing connectors and all other type of connections for low voltage aerial bundled cables.
- Draft30 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 4 applies to connectors used for the electrical connection of ABC. The connectors are designed to be installed where either the main and/or branch cable is ABC as defined by HD 626. Tests described in this document are type tests.
- Draft44 pagesEnglish languagesale 10% offe-Library read for1 day
The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. The purpose of this Part 1 is to define the common aspects of the products included in the above scope.
- Draft28 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 3 applies to tensioning devices consisting of tension and suspension clamps, and tension and suspension assemblies used for the installation of ABC with either insulated or bare neutral messenger. The tension and suspension clamps are designed to be installed on neutral conductors of ABC defined in HD 626. Tests described in this document are type tests.
- Draft35 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 2 applies to tensioning devices consisting of tension and suspension clamps, fittings and brackets designed to be used for installation of self supporting ABC defined in HD 626. Tests described in this document are type tests.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 6 defines the environmental tests in particular the climatic and corrosion ageing tests. The objective of these tests is to predict the behaviour of ABC accessories when subjected to sun radiation, to weather conditions (humidity, spraying water, heat, cold) and pollution. EN 50483 1, EN 50483 2, EN 50483 3 and EN 50483 4 specify which type tests included in this part of the standard are needed.
- Draft26 pagesEnglish languagesale 10% offe-Library read for1 day