MT 2 - Interference from overhead power lines, high-voltage equipment and electric traction
CISPR TR 18-2:2017 which is a Technical Report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The frequency range covered by this publication is 0,15 MHz to 3 GHz. A general procedure for establishing the limits of the radio noise field from the power lines and equipment is recommended, together with typical values as examples, and methods of measurement. The clause on limits concentrates on the low frequency and medium frequency bands and it is only in these bands where ample evidence, based on established practice, is available. No examples of limits to protect radio reception in the frequency band 30 MHz to 3 GHz have been given, as measuring methods and certain other aspects of the problems in this band have not yet been fully resolved. Site measurements and service experience have shown that levels of noise from power lines at frequencies higher than 300 MHz in normal operation are so low that interference is unlikely to be caused to television reception. The values of limits given as examples are calculated to provide a reasonable degree of protection to the reception of broadcasting at the boundary of the recognized service areas of the appropriate transmitters in the radio frequency bands used for a.m. radio broadcasting, in the least favourable conditions likely to be generally encountered. These limits are intended to provide guidance at the planning stage of the line and national standards or other specifications against which the performance of the line may be checked after construction and during its useful life. The measuring apparatus and methods used for checking compliance with limits should comply with the respective CISPR specifications, as e.g. the basic standards series CISPR 16, see [1]. This third edition of CISPR TR 18-2 is adapted to the modern structure and content of technical reports issued by IEC. The second edition of CISPR TR 18-2 underwent thorough edition and adaptation to modern terminology. This third edition now also covers an adequate method of measurement for radiated disturbances from HV overhead power lines and substations in the range 300 MHz to 3 GHz, since gap-type discharges can be a potential noise source disturbing modern digital radio communication.
Keywords: radio noise from overhead power lines and high-voltage equipment
- Technical report77 pagesEnglish languagesale 15% off
- Technical report154 pagesEnglish languagesale 15% off
CISPR TR 18-3:2017 which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception, excluding the fields from power line carrier signals. The frequency range covered is 0,15 MHz to 3 GHz. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- localisation system of spark discharges which might contain frequency components up to 3 GHz;
- information regarding equations for predetermination of the radio noise level from HVDC overhead power lines.
Keywords: radio noise from overhead power lines and high-voltage equipment
- Technical report52 pagesEnglish languagesale 15% off
- Technical report105 pagesEnglish languagesale 15% off
CISPR TR 18-1:2017 which is a Technical Report, applies to radio noise from overhead power lines, associated equipment, and high-voltage equipment which may cause interference to radio reception. The scope of this document includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio signals and services. The frequency range covered is 0,15 MHz to 3 GHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- updated description of the RF characteristics of spark discharges which might contain spectral radio noise components up to the GHz frequency range;
- addition of state of the art in HVDC converter technology
Keywords: radio noise from overhead power lines and high-voltage equipment
- Technical report80 pagesEnglish languagesale 15% off
- Technical report161 pagesEnglish languagesale 15% off
CISPR 18-2:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The frequency range covered is 0,15 MHz to 300 MHz. A general procedure for establishing the limits of the radio noise field from the power lines and equipment is recommended, together with typical values as examples, and methods of measurement. The clause on limits concentrates on the low frequency and medium frequency bands and it is only in these bands where ample evidence, based on established practice, is available. No examples of limits to protect radio reception in the frequency band 30 MHz to 300 MHz have been given, as measuring methods and certain other aspects of the problems in this band have not yet been fully resolved. Site measurements and service experience have shown that levels of noise from power lines at frequencies higher than 300 MHz are so low that interference is unlikely to be caused to television reception. The values of limits given as examples are calculated to provide a reasonable degree of protection to the reception of broadcasting at the boundary of the recognized service areas of the appropriate transmitters in the radio frequency bands used for a.m. broadcasting, in the least favourable conditions likely to be generally encountered. These limits are intended to provide guidance at the planning stage of the line and national standards or other specifications against which the performance of the line may be checked after construction and during its useful life. The measuring apparatus and methods used for checking compliance with limits should comply with the respective CISPR specifications, as e.g. the basic standards series CISPR 16. This second edition cancels and replaces the first edition published in 1986. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- while the first edition of CISPR 18-2 only considered the direct distance D0 for the establishment of standard profiles for the lateral radio noise field emanating from HV overhead power lines,
- this second edition now also allows for use of the lateral distance y0 for these purposes. This way it allows for conduction of on-site measurements and simplified recording and use of measurement data obtained at lateral distances y slant to the pathway of modern HV and UHV overhead power line constructions with tall suspension towers.
- Technical report72 pagesEnglish languagesale 15% off
CISPR 18-1:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The scope of this publication includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio broadcast services. The frequency range covered is 0,15 MHz to 300 MHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this technical report. This second edition cancels and replaces the first edition published in 1982. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- while the first edition of CISPR 18-1 only covered the direct distance D0 for the establishment of standard profiles for the lateral radio noise field emanating from HV overhead power lines,
- this second edition now also allows for use of the lateral distance y0 for these purposes. This way it allows for the establishment of standard profiles for the lateral radio noise field also from modern HV overhead power line constructions with tall suspension towers.
- Technical report71 pagesEnglish languagesale 15% off
CISPR 18-3:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception, excluding the fields from power line carrier signals. The frequency range covered is 0,15 MHz to 300 MHz. This second edition cancels and replaces the first edition published in 1986. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- while the first edition of CISPR 18-3 only covered recommendations for minimizing the generation of radio noise emanating from high-voltage (HV) power systems,
- this second edition now also covers a new clause providing formulae for predetermination of the radio noise field strength levels from HV overhead power lines with large conductor bundles.
Furthermore, Annex A was accomplished with a collation of predetermination formulae developed and used by several institutions around the world. The tables also contain typical examples of radio noise field strength levels obtained during some measurements campaigns at several HV overhead power line constructions.
- Technical report46 pagesEnglish languagesale 15% off
Frequently Asked Questions
MT 2 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Interference from overhead power lines, high-voltage equipment and electric traction". This committee has published 124 standards.
MT 2 develops IEC standards in the area of Information technology. Currently, there are 124 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.