IEC 61869-13:2021 is a product standard and covers only additional requirements for stand-alone merging units (SAMUs) used for AC applications having rated frequencies from 15 Hz to 100 Hz. The digital output format specification is not covered by this document; it is standardized in IEC 61869-9 as an application of IEC 61850, which specifies the power utility communication architecture.
This document covers SAMUs having standardized analogue inputs (for example: 1 A, 5 A, 3,25 V / √3 or 100 V / √3) provided by instrument transformers compliant with relevant product standards (e.g. IEC 61869-2 to IEC 61869-5, IEC 61869-7, IEC 61869-8, IEC 61869-10, IEC 61869-11, IEC 60044-1 to IEC 60044-6, IEC 60185, IEC 60186, IEEE C57.13), and aims to convert them to the digital output compliant with IEC 61869-9. Other input and output types are outside the scope of this document. Appropriate SAMU functionality can be combined with switchgear controller functionality defined in IEC 62271-3 or other IED functionality defined in IEC 60255 (all parts).
Cyber security requirements are outside the scope of this document and are covered by the IEC 62351 series.
IEC 61869-13:2021 is to be used in conjunction with IEC 61869-9:2016, Digital interface for instrument transformers, and IEC 61869­6:2016, Additional general requirements for low-power instrument transformers, which, in turn, are based on IEC 61869-1:2007, General requirements.

  • Standard
    141 pages
    English and French language
    sale 15% off

IEC 61869-15:2018 provides all requirements specific to voltage transformers to be used in DC applications (DCVTs), whatever the technology used. The output signal can be analogue or digital.
It is applicable to newly manufactured voltage transformers used for measuring, protection and/or control applications in DC power systems with a rated voltage above 1,5 kV.
This document covers passive voltage dividers as well as active voltage transformers, used for measurement, control and protection.
The general configuration of a single-pole low-power instrument transformer is described in Figure 601 of IEC 61869-6:2016.
IEC 61869-15:2018 applies to voltage transformers (VT) intended to be used in DC applications with the following functions:
• measure DC voltage (with significant harmonics);
• withstand DC voltage.
Two main technologies of DC converters exist today: LCC and VSC
• Line-commutated converters (LCC) are based on thyristor converters. They are characterized by a single direction of current flow, and a voltage polarity reversal possibility. Significant voltage and current harmonics exist up to frequencies of about 3 kHz to 4 kHz.
• Voltage source converters (VSC) are based on transistor converters. They are characterized by a bi-directional current flow and a single voltage polarity. Voltage and current harmonics exist up to frequencies of about 20 kHz.

  • Standard
    71 pages
    English and French language
    sale 15% off

IEC 61869-14:2018 provides all requirements specific to current transformers to be used in DC applications (DCCTs), whatever the technology used. The output signal can be analogue or digital.
It is applicable to newly manufactured current transformers used for measuring, protection and/or control applications in DC power systems with a rated voltage above 1,5 kV.
The general configuration of a single-pole low-power instrument transformer is described in Figure 601 of IEC 61869-6:2016.
The DCCTs intended for current measurement in the transistor branch of the VSC valve (referred to as CT4a and CT4b in Figure 1403 and Table 1402) are not covered by this document, and will be considered in a future revision.
IEC 61869-14:2018 applies to current transformers intended to be used in DC applications with at least one of the following functions:
• measure DC current (with significant harmonics);
• withstand DC voltage.
Depending on the position on the DC system, different kinds of application exist, which are briefly described below, together with the approximate voltage or current wave shape.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    85 pages
    English and French language
    sale 15% off

IEC 61869-10:2017 is a product standard and covers only additional requirements for low-power passive current transformers. The product standard for low-power passive current transformers comprises IEC 61869-1, together with IEC 61869-6 and this document with specific requirements.
This document is applicable to newly manufactured low-power passive current transformers with analogue output for use with electrical measuring instruments or electrical protective devices having a rated frequency from 15 Hz to 100 Hz.
This document covers low-power passive current transformers used for measurement or protection and multi-purpose low-power passive current transformers used for both measurement and protection.
This first edition of IEC 61869-10, together with IEC 61869-1, IEC 61869-6, IEC 61869-8 and IEC 61869-9, cancels and replaces the first edition of IEC 60044-8, published in 2002. This edition constitutes a technical revision.
The technical changes concern IEC TC 38's decision to restructure the whole set of stand-alone standards in the IEC 60044 series and transform it into a new set of standards composed of general requirements documents and specific requirements documents.

  • Standard
    87 pages
    English and French language
    sale 15% off

IEC 61869-11:2017 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed of IEC 61869-1, along with IEC 61869-6 and this document with specific requirements.
This document is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices.
This document covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection.
Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to future IEC 61869-7). Such low-power passive voltage transformers can include the secondary signal cable (transmitting cable). The secondary voltage of the low-power passive voltage transformer is proportional to the primary voltage. Derivative output signals are not within the scope of this document.
This first edition of IEC 61869-11, together with IEC 61869-1 and IEC 61869-6, cancels and replaces the relevant clauses or subclauses of the first edition of IEC 60044-7, published in 1999 and the first edition of IEC 60044-8, published in 2002. This edition constitutes a technical revision.
The contents of the Interpretation Sheet 1 of September 2021 have been included in this copy.

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 61869-6:2016(E) is a product family standard and covers only additional general requirements for low-power instrument transformers (LPIT) used for a.c. applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV and EHV or used for d.c. applications. This product standard is based on IEC 61869-1:2007, in addition to the relevant product specific standard. This part of IEC 61869 does not cover the specification for the digital output format of instrument transformers. This part of IEC 61869 defines the errors in case of analogue or digital output. The other characteristics of the digital interface for instrument transformers are standardised in IEC 61869-9 as an application of the standards, the IEC 61850 series, which details layered substation communication architecture. This part of IEC 61869 considers additional requirements concerning bandwidth. General Requirements; however, the reader is encouraged to use its most recent edition. This first edition of IEC 61869-6 cancels and replaces the relevant parts of IEC 60044-7, published in 1999, and of IEC 60044-8, published in 2002.
This publication is to be read in conjunction with IEC 61869-1:2007

  • Standard
    176 pages
    English and French language
    sale 15% off

This part of IEC 60044 applies to newly manufactured electronic current transformers having an analogue voltage output or a digital output, for use with electrical measuring instruments and electrical protective devices at nominal frequencies from 15 Hz to 100 Hz.

  • Standard
    124 pages
    English language
    sale 15% off

Applies to newly manufactured electronic voltage transformers with analogue output, for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. The standard covers optical arrangements with electronic components. Three-phase voltage transformers are not included, but some of the requirements apply.

  • Standard
    137 pages
    English and French language
    sale 15% off