This document specifies methods of determining the luminous and solar characteristics of glazing in buildings. These characteristics can serve as a basis for lighting, heating and cooling calculations of rooms and permit comparison between different types of glazing. This document applies both to conventional glazing and to absorbing or reflecting solar-control glazing, used as vertical or horizontal glazed apertures. The appropriate formulae for single, double and triple glazing are given. A matrix method is provided as an alternative calculation method. This document introduces a method to determine the luminous and solar properties of building-integrated photovoltaic (BIPV) glazing. This document is accordingly applicable to all transparent materials except those which show significant transmission in the wavelength region 5 µm to 50 µm of ambient temperature radiation, such as certain plastic materials. Materials with light-scattering properties for incident radiation are dealt with as conventional transparent materials subject to certain conditions (see 5.3). Angular light and solar properties of glass in building are excluded from this document. However, research work in this area is summarised in References [1], [2] and [3]. Guidance on the measurement of luminous and spectral properties of glass can be found in Reference [4]. Vacuum insulating glass (VIG) is excluded from the scope of this document. For determination of the g value of VIG, refer to ISO 19916-1[5].
- Standard94 pagesEnglish languagesale 15% off
This document specifies a calculation method to determine the thermal transmittance (U value) of glass with flat and parallel surfaces. This document applies to uncoated glass (including glass with structured surfaces, e.g. patterned glass), coated glass and materials not transparent in the far infrared which is the case for soda lime glass products, borosilicate glass, glass ceramic, alkaline earth silicate glass and alumino silicate glass. It applies also to multiple glazing comprising such glasses or materials, or both. It does not apply to multiple glazing which include in the gas space sheets or foils that are far infrared transparent. Vacuum insulating glass (VIG) is excluded from the scope of this document. To determine the U value of VIG, reference can be made to ISO 10291 or ISO 19916-1. The procedure specified in this document determines the U value in the central area of glazing. The edge effects due to the thermal bridge through the spacer of an insulating glass unit or through the window frame are not included. Furthermore, energy transfer due to solar radiation is not taken into account. The effects of Georgian and other bars are excluded from the scope of this document. NOTE ISO 10077-1 provides a methodology for calculating the overall U value of windows, doors and shutters, taking account of the U value calculated for the glass components according to this document. Also excluded from the calculation methodology are any effects due to gases that absorb infrared radiation in the 5 µm to 50 µm range.
- Standard17 pagesEnglish languagesale 15% off
This document specifies a procedure for determining the emissivity at room temperature of the surfaces of glass and coated glass. The emissivity is necessary for taking into account heat transfer by radiation from surfaces at the standard temperature of 283 K in the determination of the U value and of the total solar transmittance of glazing according to REF [5] \r \h ISO 9050[5] 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000040000005B0035005D000000 , REF [6] \r \h ISO 10291[6] 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000040000005B0036005D000000 , REF [7] \r \h ISO 10292[7] 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000040000005B0037005D000000 , and REF [8] \r \h ISO 10293[8] 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000040000005B0038005D000000 . The procedure, being based on spectrophotometric specular reflectance measurements at near normal incidence on materials that are non-transparent in the infrared region, is not applicable to glazing components with at least one of the following characteristics: a) with rough or structured surfaces where the incident radiation is diffusely reflected; b) with curved surfaces where the incident radiation is regularly reflected at angles unsuitable to reach the detector while using specular reflectance accessories; c) infrared transparent. However, it can be applied with caution to any glazing component provided its surfaces are flat and non-diffusing (see non-diffusing glazing component) and it is non-transparent in the infrared region (see glazing component non-transparent in the infrared region). Although transmittance measurements are included in this document, they are only necessary to check if the specimen is non-transparent in the infrared region in the context of this document (see glazing component non-transparent in the infrared region). If the specimen is transparent in the infrared region, this document is not applicable.
- Standard16 pagesEnglish languagesale 15% off
Frequently Asked Questions
ISO/TC 160/WG 8 is a Working Group within the International Organization for Standardization (ISO). It is named "Light and energy transmission properties and thermal properties of glazing". This committee has published 3 standards.
ISO/TC 160/WG 8 develops ISO standards in the area of Information technology. Currently, there are 3 published standards from this working group.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Working Group in ISO is a specialized group responsible for developing standards or technical work within a defined scope. These bodies bring together international experts to create consensus-based standards that support global trade, safety, and interoperability.