The document specifies testing procedures for determining calibration error for radiosonde humidity sensors sampled from mass production batches based on varying the levels of relative humidity at atmospheric upper-air temperatures using a laboratory setup. This document provides: technical requirements for a laboratory setup to evaluate the calibration errors of radiosonde humidity measurement; a test procedure for evaluating calibration error of radiosonde humidity sensors for a temperature range1) of −90 °C to 35 °C and for a relative humidity of 1 %rh to 100 %rh. Note, this document, is based upon relative humidity calculated by the percentage of water vapour pressure divided by saturation water vapour pressure over liquid water, not over ice, even at temperatures below 0 °C; hence, the maximum relative humidity is less than 100 %rh below 0 °C; a method for evaluating the uncertainty for the measured radiosonde humidity calibration errors. 1) Currently, the lowest possible temperature of commercially-available climate chambers is approximately -75 °C. The temperature range can be adjusted based on the capability of the climate chamber used.
- Standard24 pagesEnglish languagesale 15% off
This document specifies a test method for estimating the magnitude of radiosonde temperature sensor warming, induced by direct solar radiation, based on variations in air pressure, temperature, ventilation speed, tilt angle of its supporting sensor boom, and light illumination angle on the boom through a laboratory evaluation. This document provides the following: technical requirements for a laboratory setup to measure the effect of direct solar radiation on radiosonde temperature measurement under simulated sounding conditions; a test procedure for estimating radiosonde temperature measurement errors due to direct solar radiation in the air pressure range of 3 hPa to 1 000 hPa, temperature range1) of −70 °C to 50 °C, ventilation speed range of 3 m∙s−1 to 7 m∙s−1 at a specified irradiance (e.g. 1 000 or higher), sensor boom tilt range2) from 0° to 45° with respect to the air ventilation direction and the range of light illumination3) angle from 0° to 90° with respect to the sensor boom plane; a method to evaluate uncertainty in the results under the test conditions.
- Standard28 pagesEnglish languagesale 15% off
This document specifies a test method in terms of calibration error for radiosonde temperature sensors sampled from a batch of mass production, with varying temperature in laboratory setups at ground level pressure. This document elaborates on: a) the technical requirements for test chamber and reference thermometers as essential laboratory setups to evaluate the calibration errors of radiosonde temperature measurement; b) a test procedure including the installation of radiosondes in the test chamber, the operation of laboratory setups and the comparison between radiosonde and the temperature references for evaluating calibration errors of radiosonde temperature sensors for a temperature range of −85 °C1) to 50 °C at laboratory conditions; at c) a method for evaluating the uncertainties related to the references and the radiosonde sensors for the measured radiosonde temperature calibration error. NOTE Calibration error of radiosonde treated in this document forms only a part of the error in radiosonde sounding measurements. Regarding the errors involved in radiosonde temperature measurement on sounding, it is necessary to consider various errors as shown in Table 2 of Reference [ REF Reference_ref_14 \r \h 7 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000110000005200650066006500720065006E00630065005F007200650066005F00310034000000 ]; this document provides only a partial evaluation in laboratory tests. 1) Currently, the lowest possible temperature of commercially-available test chambers is more or less −75 °C. The temperature range can be adjusted depending on the capability of the test chambers.
- Standard12 pagesEnglish languagesale 15% off
Frequently Asked Questions
ISO/TC 146/SC 5/WG 11 is a Subcommittee within the International Organization for Standardization (ISO). It is named "Radiosonde". This committee has published 3 standards.
ISO/TC 146/SC 5/WG 11 develops ISO standards in the area of Information technology. Currently, there are 3 published standards from this subcommittee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Subcommittee (SC) in ISO operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.