This document specifies the geometry and method of use (installation and operating conditions) of
nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate
of the fluid flowing in the conduit.
This document also provides background information for calculating the flowrate and is applicable in
conjunction with the requirements given in ISO 5167-1.
This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic
throug...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      49 pages
      German language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit. This document also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout t...view more

    • sale 15% off
    • Standard
      43 pages
      English language
    • sale 15% off
    • Standard
      41 pages
      French language
    • sale 15% off
    • Draft
      45 pages
      French language
    • sale 15% off
    • Draft
      39 pages
      English language

This document specifies a method for the determination in a closed conduit of the volume rate of flow of a regular flow a) of a fluid of substantially constant density or corresponding to a Mach number not exceeding 0,25, b) with substantially uniform stagnation temperature across the measuring cross-section, c) running full in the conduit, and d) under steady flow conditions. In particular, it deals with the technology and maintenance of Pitot static tubes, with the calculation of local velocit...view more

    • sale 15% off
    • Standard
      55 pages
      English language
    • sale 15% off
    • Draft
      55 pages
      English language

2019-10-07: CEN/BT 169/2019: remove link to MDD + MDR & publish without delay
2019-10-09 - JO- BT decision - BT N 11739 - remove link to MDD
CEN/BT C082/2011:  DOW = DAV + 36 months

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      36 pages
      English language
    • e-Library read for
      1 day

ISO/IEC TR 30148:2019 (E) describes:
– the structure of wireless gas meter networks, and
– the application protocol of wireless gas meter networks

    • sale 15% off
    • Technical report
      28 pages
      English language

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits. This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter....view more

    • sale 15% off
    • Standard
      121 pages
      French language
    • sale 15% off
    • Standard
      114 pages
      English language

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the cal...view more

    • sale 15% off
    • Standard
      14 pages
      French language
    • sale 15% off
    • Standard
      13 pages
      English language

This document gives guidelines for the specification, testing, inspection, installation, operation and calibration of thermal mass gas flowmeters for the metering of gases and gas mixtures. It is not applicable to measuring liquid mass flowrates using thermal mass flowmeters. This document is not applicable to hot wire and other hot film anemometers, also used in making point velocity measurements.

    • sale 15% off
    • Standard
      30 pages
      English language

This document applies to industrial electromagnetic flowmeters used for the measurement of flowrate
of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both
alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters
running from a mains power supply and those operating from batteries or other sources of power.
This document is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed
...
view more

    • sale 15% off
    • Standard
      33 pages
      French language
    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

ISO/TR 3313:2018 defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this document because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effect...view more

    • sale 15% off
    • Technical report
      45 pages
      English language

ISO/TR 15377:2018 describes the geometry and method of use for conical-entrance orifice plates, quarter-circle orifice plates, eccentric orifice plates and Venturi tubes with 10,5° convergent angles. Recommendations are also given for square-edged orifice plates and nozzles under conditions outside the scope of ISO 5167. NOTE The data on which this document is based are limited in some cases.

    • sale 15% off
    • Technical report
      31 pages
      English language

ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power. ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to ...view more

    • sale 15% off
    • Standard
      33 pages
      French language
    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

ISO 12764:2017 a) describes the use of vortex shedding flow meters for liquids, gases, and steam, including a glossary and a set of engineering equations used for specifying performance, b) provides technical information to assist the user in selecting, specifying and applying vortex shedding flowmeters, including influence effects, c) describes typical construction and provides recommendations for inspection, certification, and material traceability, d) describes availability of diagnostics ass...view more

    • sale 15% off
    • Standard
      22 pages
      English language

This part of ISO 4064|OIML R 49 is applicable to the type evaluation and initial verification testing of
water meters for cold potable water and hot water as defined in ISO 4064-1:2014|OIML R 49‑1:2013.
OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate
System, provided that this part of ISO 4064|OIML R 49, ISO 4064-1:2014|OIML R 49‑1:2013 and
ISO 4064-3:2014|OIML R 49‑3:2013 are used in accordance with the rules of the System.
This part o...
view more

    • sale 10% off
    • Standard
      115 pages
      English language
    • e-Library read for
      1 day

This part of ISO 4064|OIML R 49 specifies the metrological and technical requirements for water meters
for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters
incorporate devices which indicate the integrated volume.
In addition to water meters based on mechanical principles, this part of ISO 4064|OIML R 49 applies to
devices based on electrical or electronic principles, and mechanical principles incorporating electronic
devices, used to meas...
view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

This part of ISO 4064 applies to water meters used to meter the volume of cold potable water and hot
water flowing through a fully charged, closed conduit. These water meters incorporate devices which
indicate the integrated volume.
This part of ISO 4064 specifies criteria for the selection of single, combination and concentric water
meters, associated fittings, installation, special requirements for meters, and the first operation of new
or repaired meters to ensure accurate constant measu...
view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day