17.120 - Measurement of fluid flow
Measurement of fluid flow
Durchflu?messungen
Mesurage de debit des fluides
Merjenje pretoka tekočin
General Information
This document provides an understanding of the nature of measurement uncertainty and its significance in estimating the "quality" of a measurement or a determination in hydrometry. This document is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.
- Standard73 pagesFrench language
sale 15% off- Draft70 pagesEnglish language
sale 15% off- Draft71 pagesFrench language
sale 15% off- Standard70 pagesEnglish language
sale 15% off
This document specifies the geometry and method of use (installation and operating conditions) of
nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate
of the fluid flowing in the conduit.
This document also provides background information for calculating the flowrate and is applicable in
conjunction with the requirements given in ISO 5167-1.
This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic
throug...view more
- Standard52 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft49 pagesGerman language
sale 10% off- e-Library read for1 day
This document specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit. This document also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout t...view more
- Standard43 pagesEnglish language
sale 15% off- Standard41 pagesFrench language
sale 15% off- Draft45 pagesFrench language
sale 15% off- Draft39 pagesEnglish language
sale 15% off
This document specifies methods of determining the stage?discharge relationship for gauging stations. It specifies an accuracy for defining the stage?discharge relationship based on a sufficient number of discharge measurements, complete with corresponding stage measurements. This document considers stable and unstable channels and includes brief descriptions of the effects on the stage?discharge relationship of the transition from inbank to overbank flows, shifting controls, variable backwater ...view more
- Standard46 pagesEnglish language
sale 15% off- Standard48 pagesFrench language
sale 15% off- Standard46 pagesEnglish language
sale 15% off
This document specifies a method for the determination in a closed conduit of the volume rate of flow of a regular flow a) of a fluid of substantially constant density or corresponding to a Mach number not exceeding 0,25, b) with substantially uniform stagnation temperature across the measuring cross-section, c) running full in the conduit, and d) under steady flow conditions. In particular, it deals with the technology and maintenance of Pitot static tubes, with the calculation of local velocit...view more
- Standard55 pagesEnglish language
sale 15% off- Draft55 pagesEnglish language
sale 15% off
This document specifies methods for the measurement of the flow of water in open channels under steady flow conditions using triangular profile weirs. The flow conditions considered are steady flows which are uniquely dependent on the upstream head and non-modular (drowned) flows which depend on downstream as well as upstream levels.
- Standard30 pagesEnglish language
sale 15% off- Standard30 pagesEnglish language
sale 15% off
2019-10-07: CEN/BT 169/2019: remove link to MDD + MDR & publish without delay
2019-10-09 - JO- BT decision - BT N 11739 - remove link to MDD
CEN/BT C082/2011: DOW = DAV + 36 months
- Amendment7 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
This document gives guidelines for selecting a particular type of flow measuring structure for measuring liquid flow in an open channel. It describes how the individual structures function in simple non-technical terms, and sets out the factors and parameters to take into account in order to make an informed decision on which type of structure to use. Values of the relevant parameters describing the limitations and uncertainty involved in the use of these structures are given in this document. M...view more
- Standard23 pagesEnglish language
sale 15% off
ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...view more
- Standard38 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft36 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...view more
- Standard21 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft18 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO/IEC TR 30148:2019 (E) describes:
– the structure of wireless gas meter networks, and
– the application protocol of wireless gas meter networks
- Technical report28 pagesEnglish language
sale 15% off
This standard describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular requirements for special categories of appliances. It applies to appliances being produced in quantity, such as in batches, series or lots, which are manufactured to the same technical specification and ...view more
- Standard25 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...view more
- Standard38 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft36 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...view more
- Standard21 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft18 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits. This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter....view more
- Standard121 pagesFrench language
sale 15% off- Standard114 pagesEnglish language
sale 15% off
IEC 60704-3:2019 is available as IEC 60704-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-3:2019 describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular r...view more
- Standard25 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the cal...view more
- Standard14 pagesFrench language
sale 15% off- Standard13 pagesEnglish language
sale 15% off
This document gives guidelines for the specification, testing, inspection, installation, operation and calibration of thermal mass gas flowmeters for the metering of gases and gas mixtures. It is not applicable to measuring liquid mass flowrates using thermal mass flowmeters. This document is not applicable to hot wire and other hot film anemometers, also used in making point velocity measurements.
- Standard30 pagesEnglish language
sale 15% off
This document applies to industrial electromagnetic flowmeters used for the measurement of flowrate
of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both
alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters
running from a mains power supply and those operating from batteries or other sources of power.
This document is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed
...view more
- Standard33 pagesFrench language
sale 15% off- Standard30 pagesEnglish language
sale 15% off- Standard35 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a method of determining discharge in open channels from observations of the surface slope and cross-sectional area of the channel. It is applicable to use under special conditions when direct measurement of discharge by typically more accurate methods, such as the velocity-area method, is not possible. Generally, the method can be used to determine discharge a) for a peak flow that left high-water marks along the stream banks, b) for a peak flow that left marks on a serie...view more
- Standard28 pagesFrench language
sale 15% off- Standard27 pagesEnglish language
sale 15% off