This document provides an understanding of the nature of measurement uncertainty and its significance in estimating the "quality" of a measurement or a determination in hydrometry. This document is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

    • sale 15% off
    • Standard
      73 pages
      French language
    • sale 15% off
    • Draft
      70 pages
      English language
    • sale 15% off
    • Draft
      71 pages
      French language
    • sale 15% off
    • Standard
      70 pages
      English language

This document specifies the geometry and method of use (installation and operating conditions) of
nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate
of the fluid flowing in the conduit.
This document also provides background information for calculating the flowrate and is applicable in
conjunction with the requirements given in ISO 5167-1.
This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic
throug...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      49 pages
      German language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit. This document also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout t...view more

    • sale 15% off
    • Standard
      43 pages
      English language
    • sale 15% off
    • Standard
      41 pages
      French language
    • sale 15% off
    • Draft
      45 pages
      French language
    • sale 15% off
    • Draft
      39 pages
      English language

This document specifies methods of determining the stage?discharge relationship for gauging stations. It specifies an accuracy for defining the stage?discharge relationship based on a sufficient number of discharge measurements, complete with corresponding stage measurements. This document considers stable and unstable channels and includes brief descriptions of the effects on the stage?discharge relationship of the transition from inbank to overbank flows, shifting controls, variable backwater ...view more

    • sale 15% off
    • Standard
      46 pages
      English language
    • sale 15% off
    • Standard
      48 pages
      French language
    • sale 15% off
    • Standard
      46 pages
      English language

This document specifies a method for the determination in a closed conduit of the volume rate of flow of a regular flow a) of a fluid of substantially constant density or corresponding to a Mach number not exceeding 0,25, b) with substantially uniform stagnation temperature across the measuring cross-section, c) running full in the conduit, and d) under steady flow conditions. In particular, it deals with the technology and maintenance of Pitot static tubes, with the calculation of local velocit...view more

    • sale 15% off
    • Standard
      55 pages
      English language
    • sale 15% off
    • Draft
      55 pages
      English language

This document specifies methods for the measurement of the flow of water in open channels under steady flow conditions using triangular profile weirs. The flow conditions considered are steady flows which are uniquely dependent on the upstream head and non-modular (drowned) flows which depend on downstream as well as upstream levels.

    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 15% off
    • Standard
      30 pages
      English language

2019-10-07: CEN/BT 169/2019: remove link to MDD + MDR & publish without delay
2019-10-09 - JO- BT decision - BT N 11739 - remove link to MDD
CEN/BT C082/2011:  DOW = DAV + 36 months

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This document gives guidelines for selecting a particular type of flow measuring structure for measuring liquid flow in an open channel. It describes how the individual structures function in simple non-technical terms, and sets out the factors and parameters to take into account in order to make an informed decision on which type of structure to use. Values of the relevant parameters describing the limitations and uncertainty involved in the use of these structures are given in this document. M...view more

    • sale 15% off
    • Standard
      23 pages
      English language

ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

ISO/IEC TR 30148:2019 (E) describes:
– the structure of wireless gas meter networks, and
– the application protocol of wireless gas meter networks

    • sale 15% off
    • Technical report
      28 pages
      English language

This standard describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular requirements for special categories of appliances. It applies to appliances being produced in quantity, such as in batches, series or lots, which are manufactured to the same technical specification and ...view more

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the c...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits. This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter....view more

    • sale 15% off
    • Standard
      121 pages
      French language
    • sale 15% off
    • Standard
      114 pages
      English language

IEC 60704-3:2019 is available as IEC 60704-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-3:2019 describes procedures for determining and verifying the declared values of the noise emitted by household and similar appliances. It applies to all categories of household and similar electrical appliances covered by IEC 60704-1 and all parts of IEC 60704-2, which include particular r...view more

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the cal...view more

    • sale 15% off
    • Standard
      14 pages
      French language
    • sale 15% off
    • Standard
      13 pages
      English language

This document gives guidelines for the specification, testing, inspection, installation, operation and calibration of thermal mass gas flowmeters for the metering of gases and gas mixtures. It is not applicable to measuring liquid mass flowrates using thermal mass flowmeters. This document is not applicable to hot wire and other hot film anemometers, also used in making point velocity measurements.

    • sale 15% off
    • Standard
      30 pages
      English language

This document applies to industrial electromagnetic flowmeters used for the measurement of flowrate
of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both
alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters
running from a mains power supply and those operating from batteries or other sources of power.
This document is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed
...
view more

    • sale 15% off
    • Standard
      33 pages
      French language
    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

This document specifies a method of determining discharge in open channels from observations of the surface slope and cross-sectional area of the channel. It is applicable to use under special conditions when direct measurement of discharge by typically more accurate methods, such as the velocity-area method, is not possible. Generally, the method can be used to determine discharge a) for a peak flow that left high-water marks along the stream banks, b) for a peak flow that left marks on a serie...view more