This standard specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions.

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This document contains the requirements for covered conductors with or without integrated longitudinal watertightness and/or semi-conductive conductor screen for applications in overhead lines with rated voltages U above 1 kV a.c. and not exceeding 36 kV a.c.

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

IEC 60172:2020 is available as IEC 60172:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring chang...view more

    • sale 15% off
    • Standard
      49 pages
      English and French language

EN 60332-3-10:2018 details the apparatus and its arrangement and calibration for methods of test for the assessment of vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions.

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

This European Standard establishes the requirements and tests for cover plates and cover tapes used for the mechanical protection, identification and warning of the location of buried cables or buried conduits.

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      14 pages
      English language
    • e-Library read for
      1 day

This document details a designation system for harmonised power cables and cords according to EN 50525 (series), EN 50214, EN 50618 and EN 50620.
NOTE The use of the system for Recognised National Types of cable or cord has been withdrawn by CLC/TC 20. For non-harmonised cables National Committees are permitted to use any designation that does not conflict with this HD, but see Tables 2 and 4 for recommendations.

    • sale 10% off
    • Standardization document
      11 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standardization document
      12 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding
wires of class 200 with a dual coating. The underlying coating is based on polyester or
polyesterimide resin, which can be modified provided it retains the chemical identity of the
original resin and meets all specified wire requirements. The superimposed coating is based
on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, silicone
resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding
wires, temperature index 200. The impregnating agent is a silicone containing resin or
varnish.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and ...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a gen...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the general requirements of enamelled rectangular copper
winding wires.
The range of nominal conductor dimensions is given in 4.1 and the relevant specification
sheet.

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of paper tape covered round copper winding
wires. This covering consists of two or more layers of paper tape and is primarily intended for
winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those sp...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin,
which can be modified provided it retains the chemical identity of the original resin and meets
all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvin...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, resin or
varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or
polyesterimide resin based.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 200 with a sole coating based on polyesterimide resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to
enhance certain performance or application characteristics.
The range of nominal conductor dimensi...
view more

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of paper tape covered round aluminium
winding wires. This covering consists of two or more layers of paper tape and is primarily
intended for winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and
IEC 60317-0-3:2008/AMD1:2013.
The paper tapes included in thi...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound fused,
unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The range of nominal conductor dimensions covered by t...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound unvarnished
and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index
155.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled round copper winding wires of
class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be
modified provided it retains the chemical identity of the original resin and meets all specified
wire requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl ac...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day