29.240.20 - Power transmission and distribution lines
Power transmission and distribution lines
Freileitungen
Lignes de transport et de distribution de courant
Daljnovodi
General Information
IEC 61897:2020 is available as IEC 61897:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61897:2020 applies to aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor. The purchaser may adopt part(s) of this document when specifying requirements for cables different from those mentioned above (...view more
- Standard32 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft28 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61854:2020 is available as IEC 61854:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61854:2020 applies to spacers for conductor bundles of overhead lines. It covers rigid spacers, flexible spacers and spacer dampers. It does not apply to interphase spacers, hoop spacers and bonding spacers. This document is written to cover the line design practices and spacers most commonly used at...view more
- Standard51 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft43 pagesEnglish language
sale 10% off- e-Library read for1 day
This document contains the requirements for covered conductors with or without integrated longitudinal watertightness and/or semi-conductive conductor screen for applications in overhead lines with rated voltages U above 1 kV a.c. and not exceeding 36 kV a.c.
- Standard28 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft28 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 62715-6-3:2020 (E) is to define the standard test methods to evaluate the mechanical robustness of flexible display modules, especially mechanical robustness regarding impact and hardness, which include displays such as liquid crystal displays (LCDs), e-paper, and organic light emitting diode (OLED) displays, against external forces applied to a panel.
- Standard14 pagesEnglish language
sale 15% off
IEC 60372:2020 is applicable to locking devices used with ball and socket couplings of string insulator units and used with the corresponding metal fittings standardized in IEC 60120, when they are supplied separately.The object of this document is
- to define the shapes and some standard dimensions for locking devices,
- to define the test methods for locking devices,
- to state the acceptance conditions for supply,
- to give other dimensions for guidance of manufacturing only.
This fourth...view more
- Standard37 pagesEnglish and French language
sale 15% off
IEC 60120:2020 define the dimensions of a series of standard ball and socket couplings using the standard locking devices (see IEC 60372) in order to permit the assembly of insulators or metal fittings supplied by different manufacturers. This document applies to string insulator units of the cap and pin and long rod types and their associated metal fittings. For the pin ball and the socket, dimensions apply to the finished product after any surface treatment. Extreme positions of the pin ball i...view more
- Standard74 pagesEnglish and French language
sale 15% off
IEC 60471:2020 applies to string insulator units of the cap and pin type and also of the long rod type as well as the fittings used with such insulators. The object of this document is to define the dimensions of a series of clevis and tongue couplings to permit the assembly of insulators or fittings supplied by different manufacturers.
This third edition cancels and replaces the second edition published in 1977. This edition includes the following significant technical changes with respect to ...view more
- Standard20 pagesEnglish and French language
sale 15% off
- Standard3 pagesEnglish and French language
sale 15% off
TAN - // IEC Corrigendum
- Corrigendum3 pagesEnglish and French language
sale 10% off- e-Library read for1 day
IEC 60895:2020 is applicable to conductive clothing, worn during live working (especially bare-hand working) on AC and DC electrical installations, to provide electrical continuity between all parts of the clothing and a reduction of electric field inside the clothing.
This document is applicable to conductive clothing assembled from a conductive garment (jackets and trousers or coveralls forming a one-piece garment) and from conductive component parts (gloves, hoods or helmets, shoes or boots,...view more
- Standard139 pagesEnglish and French language
sale 15% off
IEC 61897:2020 is available as IEC 61897:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61897:2020 applies to aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor. The purchaser may adopt part(s) of this document when specifying requirements for cables different from those mentioned above (...view more
- Standard32 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft28 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61854:2020 is available as IEC 61854:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61854:2020 applies to spacers for conductor bundles of overhead lines. It covers rigid spacers, flexible spacers and spacer dampers. It does not apply to interphase spacers, hoop spacers and bonding spacers. This document is written to cover the line design practices and spacers most commonly used at...view more
- Standard51 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft43 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61897:2020 is available as IEC 61897:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61897:2020 applies to aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor. The purchaser may adopt part(s) of this document when specifying requirements for cables different from those mentioned abov...view more
- Standard58 pagesEnglish and French language
sale 15% off
IEC 61854:2020 is available as IEC 61854:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61854:2020 applies to spacers for conductor bundles of overhead lines. It covers rigid spacers, flexible spacers and spacer dampers.
It does not apply to interphase spacers, hoop spacers and bonding spacers.
This document is written to cover the line design practices and spacers most commonly u...view more
- Standard98 pagesEnglish and French language
sale 15% off
EN 50341-2-15 is applicable for new high-voltage overhead lines only, not for existing lines in the Netherlands. This NNA includes the requirements for application of plastic cables, with metal or without (ADSS) metal, for telecommunication, as well as for conductor/earthwire (groundwire) systems (e.g. wraparound,....). This NNA is applicable for fixing of structural elements for telecommunication (e.g. dishes), if mounted on power line supports (towers), especially regarding the wind forces and...view more
- Standard63 pagesEnglish language
sale 10% off- e-Library read for1 day
1.1 General
1.1 RO.1 General
(ncpt) This Part 2-24 gives the requirements for planning, design and construction of overhead electrical lines with nominal voltages exceeding A.C. 1 kV operating at 50 Hz frequency.
The present Part 2-24 is not applicable for existing overhead electrical lines unless specifically required by Project Specification. The power installations of overhead lines, that are in different stages of design or construction, can be finalised in conformity with the standards...view more
- Standard61 pagesEnglish language
sale 10% off- e-Library read for1 day
1 Scope
1.1 General
BE.1 Scope of Part 1 and Part 2-2
(ncpt) Part 1 and the present Part 2-2 are only applicable to completely new or completely replaced overhead lines between two points, A and B, as well as to new supports on new foundations with nominal voltages above AC 50 kV.
(A-dev) Overhead lines or supports with nominal voltages exceeding AC 1 kV up to and including AC 50 kV are treated as a high voltage of the first category in the General Regulations of the Electrical Installations...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 50341-2-4 applies for planning and design of overhead lines with nominal voltages above AC 1 kV. This EN needs not to be adopted for existing installations. Installations in the planning and construction stage may be completed adopting the standard edition valid at the beginning of planning.In Germany this EN is applicable for all types of conductors (according to the information in clause 1.2) which contain components for telecommunication. In Germany this EN is applicable for the installati...view more
- Standard91 pagesEnglish language
sale 10% off- e-Library read for1 day
This document is applicable to composite line post insulators for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to line post insulators of similar design used in substations or on electric traction lines. This document applies to line post insulators of composite type, generally with metallic couplings, with and without a base plate. It also applies to such insulators when used in complex structures. It does not apply to ho...view more
- Standard35 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 61952 is applicable to composite line post insulators for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to line post insulators of similar design used in substations or on electric traction lines. This document applies to line post insulators of composite type, generally with metallic couplings, with and without a base plate. It also applies to such insulators when used in complex structures. It does not ap...view more
- Standard35 pagesEnglish language
sale 10% off- e-Library read for1 day