Standard Test Method for Calcium or Zinc in Paint Driers by EDTA Method

SIGNIFICANCE AND USE
This test method may be used to confirm the stated calcium or zinc content of pure liquid calcium or zinc driers soluble in toluene-alcohol and manufactured for use by the coatings industry.
SCOPE
1.1 This test method covers a titrimetric determination of calcium in liquid calcium driers and zinc in liquid zinc driers that can be dissolved in a toluene-alcohol mixture and utilizes the disodium salt of ethylenediaminetetraacetic acid dihydrate (EDTA).
1.2 This test method is not applicable to drier blends.
1.3 All cations that can be titrated with EDTA in alkaline media interfere and must not be present in the sample.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2006
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2613-01(2006) - Standard Test Method for Calcium or Zinc in Paint Driers by EDTA Method
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


Designation: D2613 − 01 (Reapproved 2006)
Standard Test Method for
Calcium or Zinc in Paint Driers by EDTA Method
This standard is issued under the fixed designation D2613; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope solution. The excess is titrated with a standard zinc chloride
solution using Eriochrome Black-T as the indicator.
1.1 This test method covers a titrimetric determination of
calcium in liquid calcium driers and zinc in liquid zinc driers
4. Significance and Use
that can be dissolved in a toluene-alcohol mixture and utilizes
4.1 This test method may be used to confirm the stated
the disodium salt of ethylenediaminetetraacetic acid dihydrate
calcium or zinc content of pure liquid calcium or zinc driers
(EDTA).
soluble in toluene-alcohol and manufactured for use by the
1.2 This test method is not applicable to drier blends.
coatings industry.
1.3 All cations that can be titrated with EDTA in alkaline
5. Apparatus
media interfere and must not be present in the sample.
5.1 Centrifuge, capable of developing 1000 to 2000 g.
1.4 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
6. Reagents
standard.
6.1 Purity of Reagents—Reagent grade chemicals shall be
1.5 This standard does not purport to address all of the
used in all tests. Unless otherwise indicated, it is intended that
safety concerns, if any, associated with its use. It is the
all reagents shall conform to the specifications of the Commit-
responsibility of the user of this standard to establish appro-
tee onAnalytical Reagents of theAmerican Chemical Society,
priate safety and health practices and determine the applica-
where such specifications are available. Other grades may be
bility of regulatory limitations prior to use.
used, provided it is first ascertained that the reagent is of
sufficiently high purity to permit its use without lessening the
2. Referenced Documents
accuracy of the determination.
2.1 ASTM Standards:
6.2 Purity of Water—Unless otherwise indicated, references
D600Specification for Liquid Paint Driers
towatershallbeunderstoodtomeanreagentwaterconforming
D1193Specification for Reagent Water
to Type II of Specification D1193.
E180Practice for Determining the Precision of ASTM
6.3 Buffer Solution—Add 350 mL of concentrated ammo-
Methods for Analysis and Testing of Industrial and Spe-
nium hydroxide (NH OH, sp gr 0.90) to 54 g of ammonium
cialty Chemicals (Withdrawn 2009)
chloride (NH Cl) and dilute to 1 L with water.
E300Practice for Sampling Industrial Chemicals
6.4 EDTA, Standard Solution (0.05 M)—Weigh 18.62 g of
3. Summary of Test Method
EDTA, dissolve in water and dilute to 1 L. Store in a
polyethylene or borosilicate glass bottle.
3.1 The liquid calcium or zinc drier is dissolved in toluene
andethylalcoholandtreatedwithanexcessofstandardEDTA
6.5 Indicator Mixture—Triturate 0.2 g of Eriochrome
Black-T and 100 g of sodium chloride (NaCl) and store the
mixture in a tightly stoppered bottle. This mixture remains
stable for several years.
This test method is under the jurisdiction of ASTM Committee D01 on Paint
and Related Coatings, Materials, andApplications and is the direct responsibility of
6.6 Zinc Chloride, Standard Solution (0.05 M)—Weigh
Subcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.
3.2690 g of zinc metal to 0.5 mg and dissolve in 50 mL of
Current edition approved June 1, 2006. Published June 2006. Originally
approved in 1967. Last previous edition approved in 2001 as D2613–01. DOI:
10.1520/D2613-01R06.
2 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Reagent Chemicals, American Chemical Society Specifications, American
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Chemical Society, Washington, DC. For suggestions on the testing of reagents not
Standards volume information, refer to the standard’s Document Summary page on listed by the American Chemical Society, see Analar Standards for Laboratory
the ASTM website. Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia
The last approved version of this historical standard is referenced on and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,
www.astm.org. MD.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D2613 − 01 (Reapproved 2006)
dilute hydrochloric acid (14 mL of concentrated HCl (sp gr a dropping tube and rubber bulb or eye dropper and obtain the
1.42) to 36 mL of water). Warm if necessary. Dilute to 1 L in total weight. Weigh by difference two or three 1-g specimens
a volumetric flask. (10dropsweighabout0.2g)tothenearest0.5mginto400-mL
assay beakers or wide-mouth flasks (Note 2). Add 10 mL of
7. Sampling
toluene to eac
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.