Standard Test Method for Volume Weights, Water-Holding Capacity, and Air Capacity of Water-Saturated Peat Materials

SIGNIFICANCE AND USE
This test method measures the air spaces of peat and the moisture-holding capacity on either a mass and/or a volume basis under conditions of saturation. If large spaces are present, water and air can penetrate easily. If spaces are smaller, the water holding capacity is increased. Water holding capacity is larger in humified peat materials (small inter-particulate spaces), whereas water and air-penetration is larger in unhumified peat (larger inter-particulate spaces). The spaces can also be aan indication of the oxygen available to the plant roots.
The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
SCOPE
1.1 This test method was designed to evaluate the aeration, water penetration, and water retention properties of peat under field conditions of water saturation.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Jan-2010
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2980-04(2010) - Standard Test Method for Volume Weights, Water-Holding Capacity, and Air Capacity of Water-Saturated Peat Materials
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D2980 − 04 (Reapproved 2010)
Standard Test Method for
Volume Mass, Moisture-Holding Capacity, and Porocity of
Saturated Peat Materials
This standard is issued under the fixed designation D2980; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Significance and Use
1.1 This test method was designed to evaluate the aeration, 4.1 Thistestmethodmeasurestheairspacesofpeatandthe
water penetration, and water retention properties of peat under moisture-holding capacity on either a mass and/or a volume
field conditions of water saturation. basisunderconditionsofsaturation.Iflargespacesarepresent,
water and air can penetrate easily. If spaces are smaller, the
1.2 This standard does not purport to address all of the
water holding capacity is increased. Water holding capacity is
safety concerns, if any, associated with its use. It is the
larger in humified peat materials (small inter-particulate
responsibility of the user of this standard to establish appro-
spaces), whereas water and air-penetration is larger in unhu-
priate safety and health practices and determine the applica-
mified peat (larger inter-particulate spaces). The spaces can
bility of regulatory limitations prior to use.
also be aan indication of the oxygen available to the plant
2. Referenced Documents
roots.
2.1 ASTM Standards:
4.2 The quality of the result produced by this standard is
D653Terminology Relating to Soil, Rock, and Contained
dependent on the competence of the personnel performing it,
Fluids
and the suitability of the equipment and facilities used.
D2974Test Methods for Moisture,Ash, and Organic Matter
AgenciesthatmeetthecriteriaofPracticeD3740aregenerally
of Peat and Other Organic Soils
considered capable of competent and objective testing/
D3740Practice for Minimum Requirements for Agencies
sampling/inspection/etc. Users of this standard are cautioned
Engaged in Testing and/or Inspection of Soil and Rock as
that compliance with Practice D3740 does not in itself assure
Used in Engineering Design and Construction
reliable results. Reliable results depend on many factors;
D4753Guide for Evaluating, Selecting, and Specifying Bal-
Practice D3740 provides a means of evaluating some of those
ances and Standard Masses for Use in Soil, Rock, and factors.
Construction Materials Testing
5. Apparatus
D6026Practice for Using Significant Digits in Geotechnical
Data
5.1 DispensingApparatus—Twodispensingburets,250-mL
E11Specification forWovenWireTest Sieve Cloth andTest
capacity in 1-mL subdivisions, 62-mL tolerance, pinch-cock
Sieves
type; a one-hole No. 6 rubber stopper; straight polyethylene
drying tube with serrated rubber tubing fittings, 150 mm long,
3. Summary of Test Method
3 5
19 mm ( ⁄4 in) in outside diameter, 16 mm ( ⁄8 in.) in inside
3.1 The test method sets up standardized conditions for
diameter; a 4-mesh sieve; a balance; a moisture–proof (air-
measuring the volume and mass of saturated peat. From these
tight) container; a 5-gal (20-L) bottle equipped with a siphon
data,saturatedvolumemasses,moisture-holdingcapacity(ona
device; and a stainless steel sieve circle about 16 mesh and
massandvolumebasis),drypeatvolumes,andporocitycanbe
28.7 mm in diameter to be attached to one end of the drying
determined.
tube and sealed. (Asoldering iron is useful.)Adjust the length
of the tube to match conveniently the graduation of the buret;
ThistestmethodisunderthejurisdictionofASTMCommitteeD18onSoiland then scallop the end without the sieve to allow for water
Rock and is the direct responsibility of Subcommittee D18.22 on Soil as a Medium
drainage, and insert the tube into the dispensing buret with the
for Plant Growth.
sieve side up.
Current edition approved Feb. 1, 2010. Published March 2010. Originally
approved in 1971. Last previous edition approved in 2004 as D2980–04. DOI:
10.1520/D2980-04R10.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or ACenco No. 14782-2 drying tube has been found suitable for this purpose. If
contactASTM Customer Service at service@astm.org. ForAnnual Book ofASTM you are aware of alternative suppliers, please provide this information to ASTM
Standards volume information, refer to the standard’s Document Summary page on International Headquarters. Your comments will receive careful consideration at a
the ASTM website. meeting of the responsible technical committee, which you may attend.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D2980 − 04 (2010)
6. Sample S 5 W /V (1)
r w
6.1 Place a representative field sample on a square rubber
Oven-dried:
sheet, paper, or oil cloth. Reduce the sample to the quantity
S 5 W /V (2)
required by quartering and place in a pre-tared moisture-proof d w
container. Work rapidly to prevent moisture losses.
Wet:
7. Procedure
S 5 W /V (3)
w w
7.1 Determine the moisture content on a separate test
where:
specimen by Method I or II of Test Methods D2974.
W = mass of test specimen as received, g,
r
7.1.1
...

Questions, Comments and Discussion