SCOPE
1.1 This test method describes the determination of the structural performance of exterior windows, doors, skylights, and curtain walls under cyclic air pressure differential, using a test chamber. This test method is applicable to all curtain wall assemblies, including, but not limited to, metal, glass, masonry, and stone components.
1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen, and not the structural performance of adjacent construction.
1.3 Procedure A shall be used for life cycle test loads.
1.4 Procedure B shall be used for wind event test loads.
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section .
The text of this test method references notes and footnotes that provide explanatory materials. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E1233 − 06
StandardTest Method for
Structural Performance of Exterior Windows, Doors,
Skylights, and Curtain Walls by Cyclic Air Pressure
1
Differential
This standard is issued under the fixed designation E1233; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
2
1. Scope 2. Referenced Documents
3
2.1 ASTM Standards:
1.1 This test method describes the determination of the
E330 Test Method for Structural Performance of Exterior
structural performance of exterior windows, doors, skylights,
Windows,Doors,SkylightsandCurtainWallsbyUniform
and curtain walls under cyclic air pressure differential, using a
Static Air Pressure Difference
test chamber. This test method is applicable to all curtain wall
E631 Terminology of Building Constructions
assemblies,including,butnotlimitedto,metal,glass,masonry,
E997 Test Method for Structural Performance of Glass in
and stone components.
Exterior Windows, Curtain Walls, and Doors Under the
1.2 This test method is intended only for evaluating the Influence of Uniform Static Loads by Destructive Meth-
ods
structural performance associated with the specified test
E998 Test Method for Structural Performance of Glass in
specimen, and not the structural performance of adjacent
Windows, Curtain Walls, and Doors Under the Influence
construction.
of Uniform Static Loads by Nondestructive Method
1.3 Procedure A shall be used for life cycle test loads.
E1300 Practice for Determining Load Resistance of Glass in
Buildings
1.4 Procedure B shall be used for wind event test loads.
E1886 Test Method for Performance of Exterior Windows,
1.5 The values stated in SI units are to be regarded as the
Curtain Walls, Doors, and Impact Protective Systems
standard. The values given in parentheses are for information
Impacted by Missile(s) and Exposed to Cyclic Pressure
only.
Differentials
E1996 Specification for Performance of Exterior Windows,
1.6 This standard does not purport to address all of the
Curtain Walls, Doors, and Impact Protective Systems
safety concerns, if any, associated with its use. It is the
Impacted by Windborne Debris in Hurricanes
responsibility of the user of this standard to establish appro-
4
2.2 ASCE Standard:
priate safety and health practices and determine the applica-
ASCE7(formerlyANSIA58.1) MinimumDesignLoadsfor
bility of regulatory limitations prior to use. Specific hazard
Buildings and Other Structures
statements are given in Section 7.
3. Terminology
1.7 The text of this test method references notes and
footnotes that provide explanatory materials. These notes and
3.1 Definitions—Definitions are in accordance with Termi-
footnotes (excluding those in tables and figures) shall not be
nology E631, unless otherwise indicated.
considered as requirements of the standard.
2
Additional information on curtain wall assemblies can be obtained from the
American Architectural Manufacturers’ Association, 1827 Walden Office Square,
Suite 550, Schaumburg, IL 60173.
1 3
This test method is under the jurisdiction of ASTM Committee E06 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Performance of Buildings and is the direct responsibility of Subcommittee E06.51 contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
on Performance of Windows, Doors, Skylights and Curtain Walls. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved April 1, 2006. Published April 2006. Originally the ASTM website.
4
approved in 1988. Last previous edition approved in 2000 as E1233 – 00. DOI: Available from American Society of Civil Engineers (ASCE), 1801 Alexander
10.1520/E1233-06. Bell Dr., Reston, VA 20191.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E1233 − 06
3.2 Definitions of Terms Specific to This Standard: 5. Significance and Use
3.2.1 design wind load, n—the uniform static air pressure
5.1 Thistestmethodisastandardprocedurefordetermining
differences, inward and outward, for which the specimen
structural performance under cyclic air pressure differential.
would be designed under service load conditions using con-
This typically is intended to represent the long-term effects of
ventional wind engineering specifications and concepts, ex-
repeated applications of wind load on exterior building surface
pressed in pascals (or pounds-force per square foot). This
elements or those loads that may be experienced during a
pressure is determined by either analytical or wind-t
...