ASTM E330-97e1
(Test Method)Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference
Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference
SCOPE
1.1 This test method describes the determination of the structural performance of exterior windows, curtain walls, and doors under uniform static air pressure differences, using a test chamber. This test method is applicable to curtain wall assemblies including, but not limited to, metal, glass, masonry, and stone components.
1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen and not the structural performance of adjacent construction.
1.3 The proper use of this test method requires a knowledge of the principles of pressure and deflection measurement.
1.4 This test method describes the apparatus and the procedure to be used for applying uniformly distributed test loads to a specimen.
1.4.1 Procedure A (see 10.2) shall be used when a load-deflection curve is not required.
1.4.2 Procedure B (see 10.3) shall be used when a load-deflection curve is required.
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or
withdrawn. Contact ASTM International (www.astm.org) for the latest information.
e1
Designation: E 330 – 97 An American National Standard
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Test Method for
Structural Performance of Exterior Windows, Curtain Walls,
1
and Doors by Uniform Static Air Pressure Difference
This standard is issued under the fixed designation E 330; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
e NOTE—Editorial changes were made to this standard in August 1998.
2
1. Scope 2. Referenced Documents
1.1 This test method describes the determination of the 2.1 ASTM Standards:
3
structural performance of exterior windows, curtain walls, and E 631 Terminology of Building Constructions
doors under uniform static air pressure differences, using a test E 997 Test Method for Structural Performance of Glass in
chamber. This test method is applicable to curtain wall assem- Exterior Windows, Curtain Walls, and Doors Under the
blies including, but not limited to, metal, glass, masonry, and Influence of Uniform Static Loads by Destructive Meth-
3
stone components. ods
1.2 This test method is intended only for evaluating the E 998 Test Method for Structural Performance of Glass in
structural performance associated with the specified test speci- Windows, Curtain Walls, and Doors Under the Influence of
3
men and not the structural performance of adjacent construc- Uniform Static Loads by Nondestructive Method
tion. E 1233 Test Method for Structural Performance of Exterior
1.3 The proper use of this test method requires a knowledge Windows, Curtain Walls, and Doors by Cyclic Static Air
3
of the principles of pressure and deflection measurement. Pressure Differential
1.4 This test method describes the apparatus and the proce- 2.2 ASCE Standard:
dure to be used for applying uniformly distributed test loads to ASCE 7 (formerly ANSI A58.1) Minimum Design Loads
4
a specimen. for Buildings and Other Structures
1.4.1 Procedure A (see section 11.2) shall be used when a
3. Terminology
load-deflection curve is not required.
3.1 Definitions—Definitions are in accordance with Termi-
1.4.2 Procedure B (see section 11.3) shall be used when a
load-deflection curve is required. nology E 631, unless otherwise indicated.
3.2 Definitions of Terms Specific to This Standard:
1.5 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information 3.2.1 permanent deformation, n—the displacement or
change in dimension of the specimen after the applied load has
only.
1.6 This standard does not purport to address all of the been removed and the specimen has relaxed for the specified
period of time.
safety concerns, if any, associated with its use. It is the
3.2.2 stick system, n—a curtain wall assembly composed of
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- individually framed continuous members, vertical mullions,
and horizontal rails that are installed in a sequential, piece-by-
bility of regulatory limitations prior to use. For specific hazard
statements, see Section 7. piece process. The completed system is assembled entirely in
the field.
1.7 The text of this standard references notes and footnotes
which provide explanatory materials. These notes and foot- 3.2.3 structural distress—a change in condition of the
specimen indicative of deterioration or incipient failure, such
notes (excluding those in tables and figures) shall not be
considered as requirements of the standard. as cracking, local yielding, fastener loosening, or loss of
adhesive bond.
3.2.4 test load—the specified difference in static air pressure
1
This test method is under the jurisdiction of ASTM Committee E-6 on
2
Additional information on curtain wall assemblies can be obtained from the
Performance of Buildings and is the direct responsibility of Subcommittee E06.51
American Architectural Manufacturers’ Association, 1540 East Dundee, Palantine,
on Component Performance of Windows, Curtain Walls, and Doors.
IL 60067.
Current edition approved Oct. 10, 1997. Published April 1998. Originally
3
Annual Book of ASTM Standards, Vol 04.11.
published as E 330 – 67 T. Last previous edition E 330 – 96.
4
Available from the American Society of Civil Engineers, 345 E. 45th Street,
New York, NY 10017-2398.
1
---------------------- Page: 1 ----------------------
NOTICE:¬This¬standard¬has¬either¬been¬superseded¬and¬replaced¬b
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.