Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)

SCOPE
1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.  
1.2 This specification is the metric counterpart of Specification C76.  
Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.  
Note 2-Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).

General Information

Status
Historical
Publication Date
09-Aug-2002
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C76M-02 - Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 76M – 02
METRIC
Standard Specification for
Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
1
[Metric]
This standard is issued under the fixed designation C 76M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
4
1. Scope C 150 Specification for Portland Cement
C 309 Specification for Liquid Membrane-Forming Com-
1.1 This specification covers reinforced concrete pipe in-
3
pounds for Curing Concrete
tended to be used for the conveyance of sewage, industrial
C 497M Test Methods for Concrete Pipe, Manhole Sec-
wastes, and storm water, and for the construction of culverts.
5
tions, or Tile [Metric]
1.2 This specification is the metric counterpart of Specifi-
4
C 595 Specification for Blended Hydraulic Cements
cation C 76.
C 618 Specification for Fly Ash and Raw or Calcined
NOTE 1—This specification is a manufacturing and purchase specifica-
Natural Pozzolan for Use as a Mineral Admixture in
tion only, and does not include requirements for bedding, backfill, or the
3
Concrete
relationship between field load condition and the strength classification of
C 655M Specification for Reinforced Concrete D-Load
pipe. However, experience has shown that the successful performance of
5
Culvert, Storm Drain, and Sewer Pipe [Metric]
this product depends upon the proper selection of the class of pipe, type
of bedding and backfill, controlled manufacture in the plant, and care and C 822 Terminology Relating to Concrete Pipe and Related
5
installation conforms to the construction specifications. The owner of the
Products
reinforced concrete pipe specified herein is cautioned that he must
C 1116 Specification for Fiber-Reinforced Concrete and
correlate the field requirements with the class of pipe specified and 3
Shotcrete
provide inspection at the construction site.
NOTE 2—Attention is called to the specification for reinforced concrete
3. Terminology
D-load culvert, storm drain, and sewer pipe (ASTM Designation
3.1 Definitions—For definitions of terms relating to con-
C 655M).
crete pipe, see Terminology C 822.
2. Referenced Documents
4. Classification
2.1 ASTM Standards:
4.1 Pipe manufactured in accordance with this specification
A 82 Specification for Steel Wire, Plain, for Concrete Re-
2
shall be of five classes identified as Class I, Class II, Class III,
inforcement
Class IV, and Class V. The corresponding strength require-
A 185 Specification for Steel Welded Wire Reinforcement,
2
ments are prescribed in Tables 1-5.
Plain, for Concrete
A 496 Specification for Steel Wire, Deformed, for Concrete
5. Basis of Acceptance
2
Reinforcement
5.1 Unless otherwise designated by the owner at the time of,
A 497 Specification for Steel Welded Wire Reinforcement,
2
or before placing an order, two separate and alternative bases
Deformed, for Concrete
of acceptance are permitted as follows:
A 615/A 615M Specification for Deformed and Plain
2
5.1.1 Acceptance on the Basis of Plant Load-Bearing Tests,
Billet-Steel Bars for Concrete Reinforcement
3
Material Tests, and Inspection of Manufactured Pipe for Visual
C 33 Specification for Concrete Aggregates
Defects and Imperfections—Acceptability of the pipe in all
diameters and classes produced in accordance with 7.1 or 7.2
1
This specification is under the jurisdiction of ASTM Committee C13 on
shall be determined by the results of the three-edge bearing
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
Reinforced Sewer and Culvert Pipe.
tests for either the load to produce a 0.3-mm crack, or at the
Current edition approved Aug. 10, 2002. Published October 2002. Originally
option of the owner, the load to produce a 0.3-mm crack and
published as C 76M–80. Last previous edition C 76M–00.
2
Annual Book of ASTM Standards, Vol 01.04.
3
Annual Book of ASTM Standards, Vol 04.02.
4
Annual Book of ASTM Standards, Vol 04.01.
5
Annual Book of ASTM Standards, Vol 04.05.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C76M–02
NOTE 1—The total reinforcement area of the inner circular cage and the elliptical cage shall not be less than that specified for the inner cage in Tables
1-5.
NOTE 2—The total reinforcement area of the outer circular cage and the elliptical cage shall not be less than that specified for the o
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.