Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings

ABSTRACT
This specification covers metal ceiling suspension systems used primarily to support acoustical tile or acoustical lay-in panels. Some suspension systems incorporate locking assembly details that enhance performance by providing some continuity or load transfer capability between adjacent sections of the ceiling grid. The structural classification or grade of ceiling suspension systems shall be determined by the capability of main runners or nailing bars to support a uniformly distributed load. These classifications shall be: light-duty systems; intermediate-duty systems; and heavy-duty systems. The structural classification of ceiling suspension systems shall be based on the load-carrying capacity of the main runners of the structural network. Suspension system structural members shall conform to the following tolerance requirements: metal thickness; straightness; length; overall cross-section dimensions; and section squareness.
SCOPE
1.1 This specification covers metal ceiling suspension systems used primarily to support acoustical tile or acoustical lay-in panels.  
1.2 Some suspension systems incorporate locking assembly details that enhance performance by providing some continuity or load transfer capability between adjacent sections of the ceiling grid. The test methods of Test Methods E3090/E3090M referenced in this specification do not provide the means for making a complete evaluation of continuous beam systems, nor for assessing the continuity contribution to overall system performance. However, the test methods can be used for evaluating primary structural members in conjunction with secondary members that interlock, as well as with those of noninterlocking type.  
1.3 While this specification is applicable to the exterior installation of metal suspension systems, the atmospheric conditions and wind loading require additional design attention to ensure safe implementation. For that reason, a specific review and approval should be solicited from the responsible architect and engineer, or both, for any exterior application of metal suspension systems in the construction of a new building or building modification.  
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.5 The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-May-2022
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM C635/C635M-22 - Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C635/C635M-22 - Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:C635/C635M −22
Standard Specification for
Manufacture, Performance, and Testing of Metal Suspension
1
Systems for Acoustical Tile and Lay-in Panel Ceilings
This standard is issued under the fixed designation C635/C635M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope mental practices and determine the applicability of regulatory
limitations prior to use.
1.1 This specification covers metal ceiling suspension sys-
1.6 This international standard was developed in accor-
tems used primarily to support acoustical tile or acoustical
dance with internationally recognized principles on standard-
lay-in panels.
ization established in the Decision on Principles for the
1.2 Some suspension systems incorporate locking assembly
Development of International Standards, Guides and Recom-
detailsthatenhanceperformancebyprovidingsomecontinuity
mendations issued by the World Trade Organization Technical
or load transfer capability between adjacent sections of the
Barriers to Trade (TBT) Committee.
ceilinggrid.ThetestmethodsofTestMethodsE3090/E3090M
2. Referenced Documents
referenced in this specification do not provide the means for
2
makingacompleteevaluationofcontinuousbeamsystems,nor
2.1 ASTM Standards:
for assessing the continuity contribution to overall system
B117 Practice for Operating Salt Spray (Fog) Apparatus
performance. However, the test methods can be used for
C634 Terminology Relating to Building and Environmental
evaluating primary structural members in conjunction with
Acoustics
secondary members that interlock, as well as with those of
D1735 Practice for Testing Water Resistance of Coatings
noninterlocking type.
Using Water Fog Apparatus
E3090/E3090M Test Methods for Strength Properties of
1.3 While this specification is applicable to the exterior
Metal Ceiling Suspension Systems
installation of metal suspension systems, the atmospheric
conditionsandwindloadingrequireadditionaldesignattention
3. Terminology
to ensure safe implementation. For that reason, a specific
3.1 Terms used in this standard are defined either in Termi-
review and approval should be solicited from the responsible
nology C634 or within this standard. The definition of terms
architect and engineer, or both, for any exterior application of
explicitly given within this standard take precedence over
metalsuspensionsystemsintheconstructionofanewbuilding
definitions given in Terminology C634. The definitions within
or building modification.
Terminology C634 and this standard take precedence over any
1.4 The values stated in either SI units or inch-pound units
other definitions of defined terms found in any other
are to be regarded separately as standard. The values stated in
documents, including other documents that may be referenced
each system may not be exact equivalents; therefore, each
in this standard.
system shall be used independently of the other. Combining
3.2 Definitions of Terms Specific to This Standard:
values from the two systems may result in non-conformance
3.2.1 backing board, n—a flat sheet of gypsum board to
with the standard.
which acoustical tile is attached using adhesive, screws,
1.5 The following safety hazards caveat pertains only to the
staples, or other suitable means (Fig. 1c).
test methods described in this specification. This standard does
3.2.2 bow, n—the maximum component of deviation in the
not purport to address all of the safety concerns, if any,
vertical plane of a main runner, cross runner, or wall molding
associated with its use. It is the responsibility of the user of this
where the centroidal axis of these structural components has
standard to establish appropriate safety, health, and environ-
been permanently deformed from end to end into the shape of
a simple regular curve during the manufacturing process (Fig.
2).
1
This specification is under the jurisdiction of ASTM Committee E33 on
Building and Environmental Acoustics and is the direct responsibility of Subcom-
2
mittee E33.04 on Application of Acoustical Materials and Systems. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved May 15, 2022. Published June 2022. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1969. Last previous edition approved in 2017 as C635/C635M – 17. Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/C0635_C0635M-22. the ASTM
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C635/C635M − 17 C635/C635M − 22
Standard Specification for
Manufacture, Performance, and Testing of Metal Suspension
1
Systems for Acoustical Tile and Lay-in Panel Ceilings
This standard is issued under the fixed designation C635/C635M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers metal ceiling suspension systems used primarily to support acoustical tile or acoustical lay-in panels.
1.2 Some suspension systems incorporate locking assembly details that enhance performance by providing some continuity or load
transfer capability between adjacent sections of the ceiling grid. The test methods of Test Methods E3090/E3090M referenced in
this specification do not provide the means for making a complete evaluation of continuous beam systems, nor for assessing the
continuity contribution to overall system performance. However, the test methods can be used for evaluating primary structural
members in conjunction with secondary members that interlock, as well as with those of noninterlocking type.
1.3 While this specification is applicable to the exterior installation of metal suspension systems, the atmospheric conditions and
wind loading require additional design attention to ensure safe implementation. For that reason, a specific review and approval
should be solicited from the responsible architect and engineer, or both, for any exterior application of metal suspension systems
in the construction of a new building or building modification.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.5 The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not
purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior
to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
B117 Practice for Operating Salt Spray (Fog) Apparatus
C634 Terminology Relating to Building and Environmental Acoustics
1
This specification is under the jurisdiction of ASTM Committee E33 on Building and Environmental Acoustics and is the direct responsibility of Subcommittee E33.04
on Application of Acoustical Materials and Systems.
Current edition approved Sept. 1, 2017May 15, 2022. Published September 2017June 2022. Originally approved in 1969. Last previous edition approved in 20132017 as
C635 – 13a.C635/C635M – 17. DOI: 10.1520/C0635_C0635M-17.10.1520/C0635_C0635M-22.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C635/C635M − 22
D1735 Practice for Testing Water Resistance of Coatings Using Water Fog Apparatus
E3090/E3090M Test Methods for Strength Properties of Metal Ceiling Suspension Systems
3. Terminology
3.1 Where these terms appear in this specification they shall have the meaning hereinTerms used in this standard are defined either
in Terminology C634 indicated as follows:or within this standard. The definition of terms explicitly given within this standard take
precedence over definitions given in Terminology C634. The definitions within Terminology C634 and this standard take
precedence over any other definitions of defined terms found in any other documents, including other documents that may be
refe
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.