Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster

ABSTRACT
This specification covers the installation of lathing and furring to receive interior and exterior Portland cement-based plaster. The following materials shall be used: metal plaster bases—expanded metal lath and wire laths; accessories—steel, PVC plastic, zinc alloy, and cornerite; channels—external corner reinforcement and foundation weep screed; wire; rod and strap hangers; clips; fasteners—nails and screws. Hangers and cold-rolled channel main runner shall conform to the allowable spacing and spans, respectively. The following methods are discussed: installation of hangers for suspended ceilings under wood constructions, attachment of hangers to main runners, installation of main runners, installation of cross furring, metal furring for walls, lapping of metal plaster bases, spacing of attachments for metal plaster bases, application of metal plaster bases, and application of accessories.
SCOPE
1.1 This specification covers the minimum technical requirements for lathing and furring for the application of exterior and interior portland cement-based plaster, as in Specifications C841 or C926. These requirements do not by default define a unit of work or assign responsibility for contractual purposes, which is the purview of a contract or contracts made between contracting entities.  
1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.  
1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable requirements of Test Method E90.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Dec-2017
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1063-18 - Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1063-18 - Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1063 −18
Standard Specification for
Installation of Lathing and Furring to Receive Interior and
1
Exterior Portland Cement-Based Plaster
This standard is issued under the fixed designation C1063; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This specification covers the minimum technical re-
A641/A641MSpecification for Zinc–Coated (Galvanized)
quirements for lathing and furring for the application of
Carbon Steel Wire
exterior and interior portland cement-based plaster, as in
A653/A653MSpecification for Steel Sheet, Zinc-Coated
Specifications C841 or C926. These requirements do not by
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed)
default define a unit of work or assign responsibility for
by the Hot-Dip Process
contractual purposes, which is the purview of a contract or
B69Specification for Rolled Zinc
contracts made between contracting entities.
B221Specification forAluminum andAluminum-Alloy Ex-
1.2 Where a fire resistance rating is required for plastered truded Bars, Rods, Wire, Profiles, and Tubes
C11Terminology Relating to Gypsum and Related Building
assembliesandconstructions,detailsofconstructionshallbein
Materials and Systems
accordance with reports of fire tests of assemblies that have
C841Specification for Installation of Interior Lathing and
met the requirements of the fire rating imposed.
Furring
1.3 Where a specific degree of sound control is required for
C847Specification for Metal Lath
plastered assemblies and constructions, details of construction
C926Specification for Application of Portland Cement-
shallbeinaccordancewithofficialreportsoftestsconductedin
Based Plaster
recognized testing laboratories in accordance with the appli-
C933Specification for Welded Wire Lath
cable requirements of Test Method E90.
C954SpecificationforSteelDrillScrewsfortheApplication
of Gypsum Panel Products or Metal Plaster Bases to Steel
1.4 The values stated in inch-pound units are to be regarded
Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in
as standard. The values given in parentheses are mathematical
Thickness
conversions to SI units that are provided for information only
C1002Specification for Steel Self-Piercing Tapping Screws
and are not considered standard.
for Application of Gypsum Panel Products or Metal
1.5 This international standard was developed in accor-
Plaster Bases to Wood Studs or Steel Studs
dance with internationally recognized principles on standard- C1032Specification for Woven Wire Plaster Base
ization established in the Decision on Principles for the C1280Specification for Application of Exterior Gypsum
Panel Products for Use as Sheathing
Development of International Standards, Guides and Recom-
D1784Specification for Rigid Poly(Vinyl Chloride) (PVC)
mendations issued by the World Trade Organization Technical
Compounds and Chlorinated Poly(Vinyl Chloride)
Barriers to Trade (TBT) Committee.
(CPVC) Compounds
D4216Specification for Rigid Poly(Vinyl Chloride) (PVC)
and Related PVC and Chlorinated Poly(Vinyl Chloride)
(CPVC) Building Products Compounds
E90Test Method for Laboratory Measurement of Airborne
Sound Transmission Loss of Building Partitions and
1
This specification is under the jurisdiction of ASTM Committee C11 on
Elements
GypsumandRelatedBuildingMaterialsandSystemsandisthedirectresponsibility
ofSubcommitteeC11.03onSpecificationsfortheApplicationofGypsumandOther
2
Products in Assemblies. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Jan. 1, 2018. Published April 2018. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1986. Last previous edition approved in 2017 as C1063–17a. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/C1063-18. the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1063−18
2.2 US Department of Commerce (DOC) Standards
PS 1 Voluntary Product Standard PS 1, Structural Plywood
PS 2 Voluntary Product Standard PS 2, Performance Stan-
dard for Wood-Based Structural Use Panels
3. Terminology
3.1 Definitions—For definitions relating to ceilings and
walls, see Terminology C11.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 building enclosure, n—system of building
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1063 − 17b C1063 − 18
Standard Specification for
Installation of Lathing and Furring to Receive Interior and
1
Exterior Portland Cement-Based Plaster
This standard is issued under the fixed designation C1063; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers the minimum technical requirements for lathing and furring for the application of exterior and
interior portland cement-based plaster, as in Specifications C841 or C926. These requirements do not by default define a unit of
work or assign responsibility for contractual purposes, which is the purview of a contract or contracts made between contracting
entities.
1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in
accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.
1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall
be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable
requirements of Test Method E90.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
A641/A641M Specification for Zinc–Coated (Galvanized) Carbon Steel Wire
A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the
Hot-Dip Process
B69 Specification for Rolled Zinc
B221 Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
C11 Terminology Relating to Gypsum and Related Building Materials and Systems
C841 Specification for Installation of Interior Lathing and Furring
C847 Specification for Metal Lath
C926 Specification for Application of Portland Cement-Based Plaster
C933 Specification for Welded Wire Lath
C954 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs
from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
C1002 Specification for Steel Self-Piercing Tapping Screws for Application of Gypsum Panel Products or Metal Plaster Bases
to Wood Studs or Steel Studs
C1032 Specification for Woven Wire Plaster Base
C1280 Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing
1
This specification is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of
Subcommittee C11.03 on Specifications for the Application of Gypsum and Other Products in Assemblies.
Current edition approved Dec. 1, 2017Jan. 1, 2018. Published April 2018. Originally approved in 1986. Last previous edition approved in 2017 as C1063 – 17a. DOI:
10.1520/C1063-17b. 10.1520/C1063-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1063 − 18
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D4216 Specification for Rigid Poly(Vinyl Chloride) (PVC) and Related PVC and Chlorinated Poly(Vinyl Chloride) (CPVC)
Building Products Compounds
E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
2.2 US Depar
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.