Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (Metric)

SCOPE
1.1 This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage.
1.2 This specification is the companion to inch-pound Specification C 1433.
Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

General Information

Status
Historical
Publication Date
30-Sep-2004
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1433M-04e1 - Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (Metric)
English language
24 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
e1
Designation: C 1433M – 04
METRIC
Standard Specification for
Precast Reinforced Concrete Box Sections for Culverts,
1
Storm Drains, and Sewers [Metric]
This standard is issued under the fixed designation C 1433M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Editorial changes were made throughout in April 2005.
1. Scope A 615/A 615M Specification for Deformed and Plain
Billet-Steel Bars for Concrete Reinforcement
1.1 This specification covers single-cell precast reinforced
C 31/C 31M Practice for Making and Curing ConcreteTest
concrete box sections intended to be used for the construction
Specimens in the Field
of culverts and for the conveyance of storm water industrial
C33 Specification for Concrete Aggregates
wastes and sewage.
C39 Test Method for Compressive Strength of Cylindrical
1.2 This specification is the companion to inch-pound
Concrete Specimens
Specification C 1433.
C 150 Specification for Portland Cement
NOTE 1—This specification is primarily a manufacturing and purchas-
C 309 Specification for Liquid Membrane-Forming Com-
ing specification. However, standard designs are included and the criteria
pounds for Curing Concrete
used to develop these designs are given in Appendix X1. The successful
C 497M Test Methods for Concrete Pipe, Manhole Sec-
performance of this product depends upon the proper selection of the box
tions, or Tile [Metric]
section, bedding, backfill, and care that the installation conforms to the
construction specifications. The purchaser of the precast reinforced C 595 Specification for Blended Hydraulic Cements
concrete box sections specified herein is cautioned that he must properly
C 618 Specification for Coal Fly Ash and Raw or Calcined
correlate the loading conditions and the field requirements with the box
Natural Pozzolan for Use as a Mineral Admixture in
section specified and provide for inspection at the construction site.
Portland Cement Concrete
C 822 Terminology Relating to Concrete Pipe and Related
2. Referenced Documents
Products
2
2.1 ASTM Standards:
C 989 Specification for Ground Granulated Blast-Furnace
A82 Specification for Steel Wire, Plain, for Concrete Re-
Slag for Use in Concrete and Mortars
inforcement
3
2.2 AASHTO Standards:
A 185 SpecificationforSteelWeldedWireFabric,Plain,for
Standard Specifications for Highway Bridges
Concrete Reinforcement
A 496 Specification for Steel Wire, Deformed, for Concrete
3. Terminology
Reinforcement
3.1 Definitions—For definitions of terms relating to con-
A 497 Specification for Steel Welded Wire Fabric, De-
crete pipe, see Terminology C 822.
formed, for Concrete Reinforcement
4. Types
4.1 Precast reinforced concrete box sections manufactured
1
This specification is under the jurisdiction of ASTM Committee C13 on
in accordance with this specification shall be one of two types
Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on
Acceptance Specifications and Precast Concrete Box Sections.
identified in Tables 1 and 2, and shall be designated by type,
Current edition approved Oct. 1, 2004. Published November 2004. Originally
span, rise, and design earth cover.
approved in 1999. Last previous edition approved in 2002 as C 1433M–02a.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American Association of State Highway and Transportation
the ASTM website. Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
e1
C 1433M – 04
TABLE 1 Design Requirements for Precast Concrete Box Sections Under Earth Dead and HS20 Live Load Conditions
NOTE 1—Design earth covers and reinforcement areas are based on the weight of a column of earth over the width of the box section as defined in
Appendix X1.
NOTE 2—Concrete design strength 35 MPa.
NOTE 3—The design earth cover indicated is the height of fill above the top of the box section. Design requirements are based on the material and soil
properties, loading data, and typical section as included in Appendix X1. For alternative or special designs, see 7.2.
NOTE 4—Design steel area in millimetres per linear metre of box section at those locations which are indicated on the typical section included in Fig.
1.
NOTE 5—The top section designation, for example, 900 by 600 by 100 mm indicates (interio
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.