Standard Test Method for Unconsolidated-Undrained Triaxial CompressionTest on Cohesive Soils

SCOPE
1.1 This test method covers determination of the strength and stress-strain relationships of a cylindrical specimen of either undisturbed or remolded cohesive soil. Specimens are subjected to a confining fluid pressure in a triaxial chamber. No drainage of the specimen is permitted during the test. The specimen is sheared in compression without drainage at a constant rate of axial deformation (strain controlled).
1.2 This test method provides data for determining undrained strength properties and stress-strain relations for soils. This test method provides for the measurement of the total stresses applied to the specimen, that is, the stresses are not corrected for pore-water pressure.
Note 1—The determination of the unconfined compressive strength of cohesive soils is covered by Test Method D 2166. Note 2
The determination of the consolidated, undrained strength of cohesive soils with pore pressure measurement is covered by Test Method D 4767.
1.3 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026.
1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.
1.4 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units and given in parentheses are approximate.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Feb-2003
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2850-03 - Standard Test Method for Unconsolidated-Undrained Triaxial CompressionTest on Cohesive Soils
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: D 2850 – 03
Standard Test Method for
Unconsolidated-Undrained Triaxial Compression Test on
1
Cohesive Soils
This standard is issued under the fixed designation D 2850; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope * 2. Referenced Documents
1.1 This test method covers determination of the strength 2.1 ASTM Standards:
2
and stress-strain relationships of a cylindrical specimen of D 422 Method for Particle-Size Analysis of Soils
either undisturbed or remolded cohesive soil. Specimens are D 653 Terminology Relating to Soil, Rock, and Contained
2
subjected to a confining fluid pressure in a triaxial chamber. No Fluids
2
drainage of the specimen is permitted during the test. The D 854 Test Method for Specific Gravity of Soils
2
specimen is sheared in compression without drainage at a D 1587 Method for Thin-Walled Tube Sampling of Soils
constant rate of axial deformation (strain controlled). D 2166 Test Methods for Unconfined Compressive Strength
2
1.2 This test method provides data for determining und- of Cohesive Soil
rained strength properties and stress-strain relations for soils. D 2216 Test Method for Laboratory Determination of Water
2
This test method provides for the measurement of the total (Moisture) Content of Soil and Rock
stresses applied to the specimen, that is, the stresses are not D 3740 Practice for Evaluation of Agencies Engaged in the
corrected for pore-water pressure. Testing and/or Inspection of Soil and Rock as Used in
2
Engineering Design and Construction
NOTE 1—The determination of the unconfined compressive strength of
D 4220 Practices for Preserving and Transporting Soil
cohesive soils is covered by Test Method D 2166.
2
Samples
NOTE 2—The determination of the consolidated, undrained strength of
D 4318 Test Method for Liquid Limit, Plastic Limit, and
cohesive soils with pore pressure measurement is covered by Test Method
2
D 4767.
Plasticity Index of Soils
D 4753 Specification for Evaluating, Selecting, and Speci-
1.3 All observed and calculated values shall conform to the
fying Balances and Scales for Use in Testing Soil and
guidelines for significant digits and rounding established in
2
Rock, and Related Construction Materials
Practice D 6026.
D 4767 Test Method for Consolidated-Undrained Triaxial
1.3.1 The method used to specify how data are collected,
2
Compression Test on Cohesive Soils
calculated, or recorded in this standard is not directly related to
D 6026 Practice for Using Significant Digits in Geotechni-
the accuracy to which the data can be applied in design or other
3
cal Data
uses, or both. How one applies the results obtained using this
standard is beyond its scope.
3. Terminology
1.4 The values stated in SI units are to be regarded as the
3.1 Definitions—The definitions of terms used in this test
standard. The values stated in inch-pound units and given in
method shall be in accordance with Terminology D 653.
parentheses are approximate.
3.2 Definitions of Terms Specific to This Standard:
1.5 This standard does not purport to address all of the
3.2.1 failure—the stress condition at failure for a test
safety concerns, if any, associated with its use. It is the
specimen. Failure is often taken to correspond to the maximum
responsibility of the user of this standard to establish appro-
principal stress difference (deviator stress) attained or the
priate safety and health practices and determine the applica-
principal stress difference (deviator stress) at 15 % axial strain,
bility of regulatory limitations prior to use.
whichever is obtained first during the performance of a test.
1
This test method is under the jurisdiction of ASTM Committee D18 on Soil and
Rock and is the direct responsibility of Subcommittee D18.05 on Structural
Properties of Soils.
2
Current edition approved Feb. 10, 2003. Published March 2003. Originally Annual Book of ASTM Standards, Vol 04.08.
3
approved in 1970. Last previous edition approved in 1998 as D 2850 – 95(1999). Annual Book of ASTM Standards, Vol 04.09.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 2850 – 03
vibrations if there are no visible ripples in a glass of water placed on the
3.2.2 unconsolidated-undrained compressive strength—the
loading plate
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.