Standard Practice for Security Engineering Symbols

ABSTRACT
This practice utilizes symbols to depict security systems and equipment requirements for architectural or engineering drawings that are produced either manually or by computer aided design (CAD). The symbols depicted include some symbols that have already been somewhat universally accepted or that have already been adopted by a standards-writing body. Generic symbols of a class of security device may be sufficient in some instances. Moreover, the need to provide a measure of security in the actual drawing may also suggest a need to utilize a generic symbol rather than to depict the exact device being installed. In the event that a greater level of detail is required, it is possible to combine many of the symbols to create new symbols that achieve the desired level. While some combinations of symbols are shown, it would be impractical to attempt to depict every conceivable combination of symbols.
SCOPE
1.1 This practice utilizes symbols to depict security systems and equipment requirements for architectural or engineering drawings that are produced either manually or by computer aided design (CAD). The symbols depicted include some symbols that have already been somewhat universally accepted or that have already been adopted by a standards-writing body, such as by the National Fire Protection Association.
1.2 It is not proposed that all of the symbols need to be utilized since the level of detail required for drawings is likely to vary. Generic symbols of a class of security device may be sufficient in some instances. Moreover, the need to provide a measure of security in the actual drawing may also suggest a need to utilize a generic symbol rather than to depict the exact device being installed.
1.3 In the event that a greater level of detail is required, it is possible to combine many of the symbols to create new symbols that achieve the desired level. While some combinations of symbols are shown, it would be impractical to attempt to depict every conceivable combination of symbols. It is also the intent of this practice that the symbols be capable of being continuously expanded and modified as the industry state of the art changes or as emphasis varies. For example, little attention is given to document security in the security symbols since such requirements are not generally fully met during construction periods but are rather developed and provided for subsequently. Since much of this equipment is not installed but is “placed,” such as furniture, there is only one symbol proposed (for example, for document shredders).
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
28-Feb-2011
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F967-03(2011) - Standard Practice for Security Engineering Symbols
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F967 − 03 (Reapproved 2011)
Standard Practice for
Security Engineering Symbols
ThisstandardisissuedunderthefixeddesignationF967;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
1.1 This practice utilizes symbols to depict security systems
and equipment requirements for architectural or engineering
2. Keywords
drawings that are produced either manually or by computer
2.1 computer aided design; security engineering; symbols
aided design (CAD). The symbols depicted include some
1. ANNOTATION
symbols that have already been somewhat universally accepted
or that have already been adopted by a standards-writing body,
Existing Equipment
such as by the National Fire Protection Association.
1.2 It is not proposed that all of the symbols need to be
Point and Zone Indicator
utilized since the level of detail required for drawings is likely
to vary. Generic symbols of a class of security device may be
sufficient in some instances. Moreover, the need to provide a
Connection Between Devices (for example,
measure of security in the actual drawing may also suggest a button and lock)
need to utilize a generic symbol rather than to depict the exact
Detail and Reference Drawing
device being installed.
1.3 In the event that a greater level of detail is required, it is
possible to combine many of the symbols to create new
Door Number (if more than one door in room,
symbols that achieve the desired level. While some combina-
use sub-letter)
tions of symbols are shown, it would be impractical to attempt
to depict every conceivable combination of symbols. It is also
Room or Space Number
the intent of this practice that the symbols be capable of being
continuouslyexpandedandmodifiedastheindustrystateofthe
art changes or as emphasis varies. For example, little attention
Device Number (reference device schedule)
is given to document security in the security symbols since
such requirements are not generally fully met during construc-
tion periods but are rather developed and provided for subse-
Device Reference
quently. Since much of this equipment is not installed but is
A = Drawing Sheet
“placed,” such as furniture, there is only one symbol proposed B = Detail
C = Device ⁄Zone Number
(for example, for document shredders).
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
2. ACCESS CONTROL
responsibility of the user of this standard to establish appro-
Generic Card Reader (reference door schedule or
specifications for type): P = pedestal mount
This practice is under the jurisdiction of ASTM Committee F12 on Security
Systems and Equipmentand is the direct responsibility of Subcommittee F12.10 on
Systems Products and Services.
Card Reader with Touch Pad
Current edition approved March 1, 2011. Published June 2011. Originally
approved in 1986. Last previous edition approved in 2003 as F967 – 03. DOI:
10.1520/F0967-03R11.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F967 − 03 (2011)
Token-Type Access Control Keypad Device
CCTV and Card Reader
Card Reader with Keypad
CCTV and Intercom
Split Lens CCTV with ID Card Receptacle
Card Reader with Time and Attendance
Apartment Type CCTV with House Phone and
Touch Pad (insert“ K” “
”, as appropriate for key switch)
3. ANNUNCIATION: CONSOLE/PANEL
Biometric Access Control Device (reference door
Strip (Tallyroll) Printer
schedule or specifications for type)
Touch Pad Lock or Device, Mechanical or
Printer
Electronic (reference door schedule for type)
Time Clock with Card Reader
Turnstile (reference door schedule for type and
function)
Central Processing Unit
Post and Rail (rope)
CRT (cathode ray tube/display)
Generic Screening Device
X: M = Metal Detector
E = Explosive Detector
X = X-ray
Static Map Display (for dynamic map display,
T = Tag Detector (EAS)
use CRT symbol)
Sally Port
Keyboard
Indicating Interlocking Doors
Jeweled Signal Light
Indicating Space is a “Man-Trap”
Panel Light Indicator (R = Red, A = Amber, W
= White, V = Violet, G = Green, Y = Yellow,
B = Blue, O = Orange)
Card Access Reader
B = Barcode
W = Wiegand
P = Proximity
Multiplex Panel
M = Mag Stripe
F = Elevator Floor Call
H = Elevator Hall Call
T = Token
Panel Sound Indicator
S = Smart Card
Biometrics Access Control Device
Panel Sound and Light Indicator
H = Hand Geometry
F = Finger Print
V = Voice
R = Eye Retina
I = Eye Iris
F967 − 03 (2011)
Reset Buzzer
Push-Button, Momentary/Make (circuit
Generic Bell
closing)
Generic Chime
Time Delay Module
Control Device Module, Door Release Generic Security Horn (differentiate from fire
horn; use also for local alarm)
End-of-Line Device Module
Audio Device
T: L = Lock
C = Camera
I = Intercom
Resistance (Ohms) (indicate value; that is,
10 000Ω)
Thousands
5. BARRIERS AND VEHICLE CONTROLS
Generic Fence (reference type in specification or
schedule)
Dry Contacts, Set
X: (Fence Type)
Y: (Sensor Type, see below)
Contacts with Current
Generic Masonry (reference type in specification
or schedule)
Power Switch X: C = Chain Link; W = Welded Mesh;
B = Barbed Top; R = Razor Ribbon
Y: E = Electrostatic; T = Taut Wire;
V = Vibration
Field Panel
T: C = Card Reader
A = Alarm
Ditch Barrier
Ditch and Berm Barrier
Control Panel
T: B = Burglar
Roll-Up Gate
F = Fire
P = Perimeter
D = Door
Sliding Gate
Central Processing Unit
Swing Gate
Traffic Arm
Keyboard
Traffic Lights (use “M” for miniature)
Printer
Generic Vehicle Sensor (reference specification
or schedule for type)
Power Supply
T: L = Lock
Tire Treddle
C = Camera
P = Panel
I = Intercom
Security Grill with Emergency Release
4. ANNUNCIATION: DEVICES
Annunciation Device, Generic
F967 − 03 (2011)
Security Grill Flush Mount Panel Board/Cabinet
Generic Security Screen
Surface Mount Panel Board/Cabinet
Repair/Secure Window Operator (use “R” for
Intercom
repair,“ S” for security)
T: M = Master
S = Substation
Turnstile
Two-Way Radio Microphone
Revolving Door
Cellular Transmitter
Traffic Arm
Vehicle Loop Detector
Telephone Dialer
T: D = Digital Communicator
V = Voice Dialer
Fiber Optic Module
Security Window Screen
T: Tx = Transmitter
T: S = Shade
R = Receiver
B = Blind (see Section 10 for alarm screen)
T = Transceiver
7. ELECTRICAL
6. COMMUNICATIONS
Resistor
Telephone Handset
End-of-Line Device
Intercom, Master, Hands-Free (use “S” for slave
or sub)
Amplifier
Intercom, Push-to-Talk
Generic Speaker (reference specification or
schedule for type)
Antenna
Nurse Station, Master, Wall Mount (use “D” for
desk mount)
Antenna, Loop
Nurse Call System Device, Generic
Battery
Paging System Device, Generic
Stand-By Battery
Private Telephone System Device, Generic
Capacitor
Public Telephone System Device, Generic
Circuit Breaker
Two-Way Radio Base Station
F967 − 03 (2011)
Intersection, Connection
Ground
Conduit Run, Exposed, Turn Down (rigid
steel—1 in.)
Circuit Return, Common
Conduit Run, Exposed, Armored
Conduit Run, Concealed, Turn Up (EMT)
Circuit Return, Frame
Conduit Run, Exposed, Turn Up (PVC)
Relay, Normally Open
Booster
Relay, Normally Closed
Shielded Cable
Relay
Coaxial Cable
Conductor, Twisted Pair
Transformer
Conductor, Security System (4 conductors, No.
18 AWG)
Transformer (on floor plan)
Fiber Optic Cable
Rectifier
Local Radio Signal Link
Long Range Radio Signal Link
Diode
Visual Signaling Device
Power Panel
Fuse
Home Run, 2 Conductors, 18 AWG (number of
arrows indicates number of circuits)
Motor
Feeder
Generator
Manhole
Junction Box, in Ceiling
Rotary Switch
Junction Box, Wall
Toggle Switch, SPST
Electrical Outlet, Wall, Duplex
Toggle Switch, SPDT
Triplex Receptacle
Nonlocking, Momentary Circuit
Closing (make)
Intersection, No Connection
F967 − 03 (2011)
Nonlocking, Momentary Circuit Illuminate this Area
Opening (break)
Transfer
Infrared Illuminator
Locking, Circuit Closing (make)
Street Light, Pole-Mounted
Locking, Circuit Opening (break)
9. MISCELLANEOUS
Security Container; Safe; File Cabinet
Form A, SPST, N.O.
Document Destroyer
Form B, SPST, N.C.
Form C, SPDT
Safe, Tack-Welded to Structural Member
SPST (Single-Pole, Single-Throw)
Signage
SPDT (Single-Pole, Double-Throw)
Bar/Grill/Seal this Location
DPST (Double-Pole, Single-Throw)
Timer
DPDT (Double-Pole, Double-Throw)
Gun Port
8. LIGHTING
10. SENSORS
Incandescent Light Fixture, Flush, Ceiling
Generic Volumetric Motion Sensor (Mono)
Mount
X: M = Microwave
I = Passive IR
U = Ultrasonic
Incandescent Light Fixture, Flush, Wall Mount
D = Dual Tech
Generic Volumetric Beam Sensor (Bi-Static)
X: M = Microwave
Incandescent Light Fixture, Surface,
I = Infrared
Ceiling Mount
P = Photo-cell
Incandescent Light Fixture, Surface,
Wall Mount
Generic Glass Breakage Sensor
T: A = Audio
S = Shock
Fluorescent Fixture, Ceiling Mount
Dedicated Security Lighting, Low Pressure So-
dium (use other
...

Questions, Comments and Discussion