SCOPE
1.1 This index identifies specifications that cover ductile iron pressure pipe suitable for carrying water and other liquids under pressure.
Note 1: The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
´1
Designation: A377 −18 (Reapproved 2022)
Standard Index of Specifications for
Ductile Iron Pressure Pipe
This standard is issued under the fixed designation A377; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
ε NOTE—3.2 was updated editorially in October 2022.
1. Scope 3.2 Other American National Standards relating to ductile-
iron pipe are the following:
1.1 This index identifies specifications that cover ductile
ANSI/AWWA C104/A21.4, Cement-Mortar Lining for
iron pressure pipe suitable for carrying water and other liquids
2,3
Ductile-Iron Pipe and Fittings
under pressure.
ANSI/AWWA C105/A21.5, Polyethylene Encasement for
NOTE 1—The text of this standard references notes and footnotes which
2,3
Ductile-Iron Pipe Systems
provide explanatory material. These notes and footnotes (excluding those
in tables and figures) shall not be considered as requirements of the ANSI/AWWA C150/A21.50, Thickness Design of Ductile-
2,3
standard.
Iron Pipe
1.2 This international standard was developed in accor-
ANSI/AWWA C110/A21.10, Ductile-Iron and Gray-Iron
2,3
dance with internationally recognized principles on standard-
Fittings
ization established in the Decision on Principles for the
ANSI/AWWA C111/A21.11, Rubber-Gasket Joints for
Development of International Standards, Guides and Recom- 2,3
Ductile-Iron Pressure Pipe and Fittings
mendations issued by the World Trade Organization Technical
ANSI/AWWAC115/A21.15, Flanged Ductile-Iron Pipe with
Barriers to Trade (TBT) Committee.
2,3
Ductile-Iron or Gray-Iron Threaded Flanges
2. Method of Designation ANSI/AWWA C116/A21.16, Protective Fusion-Bonded
Coatings for the Interior and Exterior Surfaces of Ductile-Iron
2.1 The ASTM designation for these specifications is not
2,3
and Gray-Iron Fittings
sufficient to describe the particular items a purchaser may
ANSI/AWWA C153/A21.53, Ductile Iron Compact
desire; therefore, the ANSI designation for the applicable
2,3
Fittings
American National Standards shown in Section 3 shall be
specified in the inquiry, contract, and order. ANSI/AWWA C600, Installation of Ductile-Iron Mains and
2,3
Their Appurtenances
3. Reference Specifications
2,3
ANSI/AWWA C606, Grooved and Shouldered Joints
3.1 Ductile iron pipe furnished in accordance with this
NOTE 2—These specifications were prepared by appropriate subcom-
index are covered by the following American National Stan-
mittees ofAmerican Water WorksAssociation CommitteeA21 on Ductile
dards:
Iron Pipe and Fittings. This committee was originally organized as an
ANSI/AWWA C151/A21.51, Ductil
...
This May Also Interest You
ABSTRACT
This specification covers high-silicon iron pipe and pipe fittings intended for corrosion-resistant service for both above- and below-grade construction. The castings shall be true to pattern, reasonable smooth, and free from defects that would make the castings unfit for the use for which they are intended. The material shall conform to the chemical composition requirements specified. All centrifugally cast high-silicon iron pipe shall be supplied in the as-cast condition. All other pipe and fittings shall be supplied in the stress-relieved condition; the stress relieving procedures are presented. Acid-proof joints for hub/plain-end pipe shall require the use of an acid-proof rope packing. No-hub pipe and fittings shall require a special acid resistant mechanical joint coupling. High-silicon iron pipe can be cut with either manual or hydraulic snap cutters. Hydrostatic testing shall be conducted on all castings.
SCOPE
1.1 This specification covers high-silicon iron pipe and pipe fittings intended for corrosion-resistant service for both above- and below-grade construction.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 Pipe and pipe fittings shall be the no-hub (MJ) or the hub and plain-end design.
1.4 Pipe and pipe fittings shall be of the sizes specified in Table 1 and Table 2 and Figs. 1–71 or other sizes that shall be permitted to conform to the requirements given herein.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: Flange dimensions are 150 lb ANSI standard.
Note 2: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Size, in.
t, in.
Weight, lb
Working
Length, ft
Overall Length
2
5/16
0.31
7
7 ft 25/8 in.
3
5/16
0.31
7
7 ft 25/8 in.
4
5/16
0.31
7
7 ft 25/8 in.
6
13/32
0.40
7
7 ft 3 in.
8
13/32
0.40
7
7 ft 3 in.
10
5/8
0.62
7
7 ft 37/8 in.
12
5/8
0.62
5
5 ft 4 in.
15
7/8
0.75
5
5 ft 41/8 in.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: Depth of seal on all traps shall be 21/2 in.
Note 2: 1 in. = 25.4 mm.
Note 1: Depth of seal on all traps shall be 21/2 in.
Note 2: 1 in. = 25.4 mm.
Note 1: Single hub vent is located on the inlet side. Depth of seal on 8 and 10 in. traps is 3 in. All others 21/2 in.
Note 2: 1 in. = 25.4 mm.
Note 1: 1 in. = 25.4 mm.
Note 1: 1 in...
- Technical specification26 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers ductile iron gravity sewer pipe centrifugally cast with push-on joints. This also covers trench load design procedures for both cement-lined pipe and flexible-lined pipe. Maximum depths of cover tables are included for both types of linings. Each pipe shall be subjected to a hydrostatic test and maybe performed either before or after the outside coating and inside coating have been applied, but shall be performed before the application of cement-mortar lining or of a special lining. The standard acceptance tests and additional control tests shall also be performed.
SCOPE
1.1 This specification covers 4 to 64 in. ductile iron gravity sewer pipe, centrifugally cast, with push-on joints. This specification may be used for pipe with other types of joints, as may be agreed upon at the time of purchase.
1.2 This specification covers trench load design procedures for both cement-lined pipe and flexible-lined pipe. Maximum depth of cover tables are included for both types of linings.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification24 pagesEnglish languagesale 15% off
ABSTRACT
This practice covers the standard materials and installation procedures for polyethylene encasement to be applied to underground installations of ductile iron pipe for water or other liquids. It may also be used for polyethylene encasement of fittings, valves, and other appurtenances to ductile iron pipe systems. Linear low-density and high-density cross-laminated polyethylene films shall be manufactured of virgin polyethylene material, and shall conform to the required group, density, dielectric strength, and volume resistivity specifications. The polyethylene encasement material shall also be in accordance to the tensile strength, elongation, dielectric strength, impact resistance, and propagation tear resistance requirements. The polyethylene encasement shall be installed in such a way that it shall prevent contact between the pipe and the surrounding backfill and bedding material without intending to be a completely airtight or watertight enclosure. The polyethylene film shall be fitted to the contour of the pipe with sufficient slack to prevent stretching the polyethylene bridging irregular surfaces. For installations below the water table or in areas subject to tidal actions, or both, it is recommended that tube-form polyethylene be used with both ends sealed as thoroughly as possible with adhesive tape or plastic tie straps at the joint overlap.
SCOPE
1.1 This practice covers materials and installation procedures for polyethylene encasement to be applied to underground installations of ductile iron pipe. It may also be used for polyethylene encasement of fittings, valves, and other appurtenances to ductile iron pipe systems.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Important SI values are provided in brackets. Also, certain important SI values appear without brackets or parentheses.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers ductile-iron culvert pipe centrifugally cast. The pipe shall be manufactured of ductile iron that meets the mechanical requirements such as tensile strength, yield strength, elongation, and impact value. The pipe shall be provided with suitable joints, such as push-on or other types of joints that prevent lateral displacement, but plain-end pipe for use with suitable couplings may be furnished. Standard wall thickness and weight values of push-on joint pipe are given. Pressure Class ductile iron pipe in Type 5 trench is illustrated. All pipe shall be coated inside and outside with an asphaltic material. Acceptance tests by tension and Charpy impact testing shall be performed. The standard test specimens for these testing methods are detailed.
SCOPE
1.1 This specification covers 14 to 64 in. ductile iron culvert pipe, centrifugally cast.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat pertains only to the test methods portions, Sections 6 and 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers the materials and testing of shield hubless couplings to join hubless cast iron soil pipe and fittings. Gaskets shall comply with the required physical and chemical properties, dimensions, and material specifications. The rubber gasket shall conform to the required physical requirements such as tensile strength, elongation, durometer, accelerated aging, compression set, oil immersion, ozone cracking, tear resistance, and water absorption. The shield and clamp assembly shall be made of material conforming to the requirements such as tensile strength and hardness. All parts shall be made of 300 series stainless steel, namely: Type 301; Type 304; Type 300; Type 301; and Type 305. The material shall also undergo physical tests like deflection, shear, and unstrained hydrostatic tests.
SCOPE
1.1 This specification covers the materials and testing of shielded hubless couplings to join hubless cast iron soil pipe and fittings.
1.2 Several different types of hubless couplings are available for use in hubless cast iron sanitary and storm drain, waste, and vent piping applications to connect hubless cast iron soil pipe and fittings by using a sleeve-type, or some other type coupling device. It is the purpose of this specification to furnish information as to the characteristics of one such sleeve-type couplings when applied to cast iron soil pipe and fittings manufactured in accordance with Specification A888, latest revision, and CISPI 301, latest revision.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 The committee with jurisdiction over this standard is aware of other comparable standard published by the Cast Iron Soil Pipe Institute, CISPI 310, FM 1680 published by Factory Mutual, and Specification C1540 published by ASTM.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification9 pagesEnglish languagesale 15% off
- Technical specification9 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers wall seamless and welded carbon and alloy steel pipe intended for use at low temperatures. The pipe shall be made by the seamless or welding process with the addition of no filler metal in the welding operation. All seamless and welded pipes shall be treated to control their microstructure. Tensile tests, impact tests, hydrostatic tests, and nondestructive electric tests shall be made in accordance to specified requirements.
SCOPE
1.1 This specification2 covers nominal (average) wall seamless and welded carbon and alloy steel pipe intended for use at low temperatures and in other applications requiring notch toughness. Several grades of ferritic steel are included as listed in Table 1. Some product sizes may not be available under this specification because heavier wall thicknesses have an adverse effect on impact properties.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
Note 1: The dimensionless designator NPS (nominal pipe size) has been substituted in this standard for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification8 pagesEnglish languagesale 15% off
- Technical specification8 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers seamless ferritic alloy-steel pipe for high-temperature service. The pipe shall be suitable for bending, flanging (vanstoning), and similar forming operations, and for fusion welding. Grade P2 and P12 steel pipes shall be made by coarse-grain melting practice. The steel material shall conform to chemical composition, tensile property, and hardness requirements. Each length of pipe shall be subjected to the hydrostatic test. Also, each pipe shall be examined by a non-destructive examination method in accordance to the required practices. The range of pipe sizes that may be examined by each method shall be subjected to the limitations in the scope of the respective practices. The different mechanical test requirements for pipes, namely, transverse or longitudinal tension test, flattening test, and hardness or bend test are presented.
SCOPE
1.1 This specification2 covers nominal wall and minimum wall seamless ferritic alloy-steel pipe intended for high-temperature service. Pipe ordered to this specification shall be suitable for bending, flanging (vanstoning), and similar forming operations, and for fusion welding. Selection will depend upon design, service conditions, mechanical properties, and high-temperature characteristics.
1.2 Several grades of ferritic steels (see Note 1) are covered. Their compositions are given in Table 1.
Note 1: Ferritic steels in this specification are defined as low- and intermediate-alloy steels containing up to and including 10 % chromium.
1.3 Supplementary requirements (S1 to S9) of an optional nature are provided. Supplementary requirements S1 through S6 call for additional tests to be made, and when desired, shall be so stated in the order together with the number of such tests required as applicable.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
Note 2: The dimensionless designator NPS (nominal pipe size) has been substituted in this standard for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification11 pagesEnglish languagesale 15% off
- Technical specification11 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers seamless and welded black and hot-dipped galvanized steel pipe in NPS 1/8 to NPS 26. The steel categorized in this standard must be open-hearth, basic-oxygen or electric-furnace processed and must have the following chemical requirements: carbon, manganese, phosphorus, sulfur, copper, nickel, chromium, molybdenum, and vanadium. The tubing shall undergo a seamless or welding process. Tension, bend, and flattening tests shall be performed to make sure that it must adhere to the mechanical properties of the standard. The hydrostatic test shall be applied, without leakage through the weld seam or the pipe body. Nondestructive electric test shall be made to make sure that the full volume of the pipe must be in accordance with the standard. The purchaser shall have the right to perform any of the inspections and tests set forth in this specification where deemed necessary to ensure that the pipe conforms to the specified requirements.
SCOPE
1.1 This specification2 covers seamless and welded black and hot-dipped galvanized steel pipe in NPS 1/8 to NPS 26 [DN 6 to DN 650] (Note 1), inclusive, with nominal wall thickness (Note 2) as given in Table X2.2 and Table X2.3. It shall be permissible to furnish pipe having other dimensions provided that such pipe complies with all other requirements of this specification. Supplementary requirements of an optional nature are provided and shall apply only when specified by the purchaser.
Note 1: The dimensionless designators NPS (nominal pipe size) [DN (diameter nominal)] have been substituted in this specification for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
Note 2: The term nominal wall thickness has been assigned for the purpose of convenient designation, existing in name only, and is used to distinguish it from the actual wall thickness, which may vary over or under the nominal wall thickness.
1.2 This specification covers the following types and grades:
1.2.1 Type F—Furnace-butt-welded, continuous welded Grades A and B,
1.2.2 Type E—Electric-resistance-welded, Grades A and B, and
1.2.3 Type S—Seamless, Grades A and B.
Note 3: See Appendix X1 for definitions of types of pipe.
1.3 Pipe ordered under this specification is intended for mechanical and pressure applications and is also acceptable for ordinary uses in steam, water, gas, and air lines. It is suitable for welding, and suitable for forming operations involving coiling, bending, and flanging, subject to the following qualifications:
1.3.1 Type F is not intended for flanging.
1.3.2 When pipe is required for close coiling or cold bending, Grade A is the preferred grade; however, this is not intended to prohibit the cold bending of Grade B pipe.
1.3.3 Type E is furnished either nonexpanded or cold expanded at the option of the manufacturer.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 The following precautionary caveat pertains only to the test method portion, Sections 7, 8, 9, 13, 14, and 15 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory requirements prior to use.
1.6 The text of this specification contains notes or footnotes, or both, that provide explanatory material. Such notes and footnotes, excluding those in tables and figures, do not contain any mandatory requirements.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization ...
- Technical specification23 pagesEnglish languagesale 15% off
- Technical specification23 pagesEnglish languagesale 15% off
ABSTRACT
This guide covers standard specification for straight seam or spinal seam electric-fusion-welded, light-wall, austenitic chromium-nickel alloy steel pipe for corrosive or high-temperature service. The sizes covered shall include NPS 14 to 30 with extra light (Schedule 5S) and light (Schedule 10S) wall thickness. Several grades of alloy steel shall be covered and shall conform to the required chemical composition for carbon, manganese, phosphorus, sulfur, silicon, nickel, chromium, molybdenum, titanium, columbium, cerium, and other elements. The chemical composition of the welding filler metal shall also conform to the requirements of the applicable AWS specification for the corresponding grade. Tensile properties of the plate or sheet used in making the pipe shall conform to the prescribed values of tensile strength and yield strength. Mechanical tests such as tension test and transverse guided-bend weld test shall be conducted. Pressure or nondestructive electric test shall also be performed.
SCOPE
1.1 This specification2 covers straight seam or spiral seam electric-fusion-welded, light-wall, austenitic chromium-nickel alloy steel pipe for corrosive or high-temperature service. The sizes covered are NPS 14 to 30 with extra light (Schedule 5S) and light (Schedule 10S) wall thicknesses. Table X1.1 shows the wall thickness of Schedule 5S and 10S pipe. Pipe having other dimensions may be furnished provided such pipe complies with all other requirements of this specification.
1.2 Several grades of alloy steel are covered as indicated in Table 1.
1.3 Optional supplementary requirements are provided. These call for additional tests to be made, and when desired shall be stated in the order, together with the number of such tests required.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
Note 1: The dimensionless designator NPS (nominal pipe size) has been substituted in this standard for such traditional terms as nominal diameter, size, and nominal size.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification7 pagesEnglish languagesale 15% off
- Technical specification7 pagesEnglish languagesale 15% off
ABSTRACT
The specification covers seamless and straight-seam welded ferritic/austenitic steel pipe for general corrosive service, with particular emphasis on resistance to stress corrosion cracking. The pipe shall be made by the seamless or an automatic welding process, with no addition of filler metal in the welding operation. Heat analysis shall be made to determine the percentages of the elements specified. Tension tests, hardening tests, flattening tests, hydrostatic tests and nondestructive electric tests shall be made to conform to the specified requirements.
SCOPE
1.1 This specification2 covers seamless and straight-seam welded ferritic/austenitic steel pipe intended for general corrosive service, with particular emphasis on resistance to stress corrosion cracking. These steels are susceptible to embrittlement if used for prolonged periods at elevated temperatures.
1.2 Optional supplementary requirements are provided for pipe when a greater degree of testing is desired. These supplementary requirements call for additional tests to be made and, when desired, one or more of these may be specified in the order.
1.3 Appendix X1 of this specification lists the dimensions of welded and seamless stainless steel pipe as shown in ANSI B36.19. Pipe having other dimensions may be furnished provided such pipe complies with all other requirements of this specification.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the M designation of this specification is specified in the order.
Note 1: The dimensionless designator NPS (nominal pipe size) has been substituted in this standard for such traditional terms as nominal diameter, size, and nominal size.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.