This European Standard is a complementary document for the installation of ductile iron pipes, fittings, accessories and their joints, covered by EN 598:2009 harmonized standard. It is intended to describe, in a wider perspective, installation technologies, tools and pipelines particular examples, applicable for the construction, outside buildings, of:
- Drainage pipeline systems;
- Raw water pipeline systems;
- Sewage pipeline systems;
- Pipeline systems conveying surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- Operating without pressure (gravity sewers) or with positive or negative pressure;
- Below or above ground installation types.
It also gives some site operation/site instructions for the application of fittings, intended to be used for the connection of ductile iron drains and sewers to other materials as plastic, concrete, vitrified clay, etc.
This European Standard is not intended to cover:
- Hydraulic design of drains and sewers systems outside buildings. For this purpose, EN 16933-2 applies.
- Construction and site testing of drains and sewers. For this purpose, EN 1610 applies.
- Trenchless construction and testing of drains and sewers. For this purpose, EN 12889:2000 applies
- Technical report56 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is a complementary document for the installation of ductile iron pipes, fittings, accessories and their joints, covered by EN 598:2009 harmonized standard. It is intended to describe, in a wider perspective, installation technologies, tools and pipelines particular examples, applicable for the construction, outside buildings, of:
- Drainage pipeline systems;
- Raw water pipeline systems;
- Sewage pipeline systems;
- Pipeline systems conveying surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- Operating without pressure (gravity sewers) or with positive or negative pressure;
- Below or above ground installation types.
It also gives some site operation/site instructions for the application of fittings, intended to be used for the connection of ductile iron drains and sewers to other materials as plastic, concrete, vitrified clay, etc.
This European Standard is not intended to cover:
- Hydraulic design of drains and sewers systems outside buildings. For this purpose, EN 16933-2 applies.
- Construction and site testing of drains and sewers. For this purpose, EN 1610 applies.
- Trenchless construction and testing of drains and sewers. For this purpose, EN 12889:2000 applies
- Technical report56 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies dimensions, tolerances, internal and external surface characteristics and marking of welded fittings for the food and chemical industry.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the technical delivery requirements for seamless and welded butt welding fittings (elbows, concentric and eccentric reducers, equal and reducing tees, caps) made of carbon and alloy steel in two test categories which are intended for pressure purposes at room temperature, at low temperature or at elevated temperatures, and for the transmission and distribution of fluids and gases.
It specifies:
a) type of fittings;
type A: Butt-welding fittings with reduced pressure factor;
type B: Butt-welding fittings for use at full service pressure;
b) steel grades and their chemical compositions;
c) mechanical properties;
d) dimensions and tolerances;
e) requirements for inspection and testing;
f) inspection documents;
g) marking;
h) protection and packaging.
NOTE The selection of the appropriate fitting (material, thickness) is the ultimate responsibility of the manufacturer of the pressure equipment (see European Legislation for Pressure Equipment). In the case of a harmonized supporting standard for materials, presumption of conformity to the ESRs is limited to technical data of materials in the standard and does not presume adequacy of the material to a specific item of equipment. Consequently, it is essential that the technical data stated in the material standard be assessed against the design requirements of this specific item of equipment to verify that the ESRs of the PED are satisfied.
- Standard145 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, test/assessment methods and of how to express test/assessment results. Cast iron pipelines kits are usually composed by cast iron pipes, fittings, joints and accessories.
This document covers the range of nominal diameter from DN /40 to DN 600 inclusive.
The cast iron includes grey cast iron and ductile cast iron.
The roof gullies used for siphonic systems are outside the scope of this standard.
Sewerage applications are outside the scope of this standard.
It is intended to be used for the construction of gravity or vacuum discharge pressurized or unpressurised networks installed inside and/or outside Works, above and/or below ground, in construction works.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This document contains definitions, thread dimension, reference data (minimum bore), supporting information (assembling instructions) and describes the test methods referenced by other parts of the EN 1254 series.
Thread dimensions comprise: wall thickness at threaded portions of fittings, dimensions of tail pipe ends for swivel fittings, dimensions of gas union connectors, thread dimensions and thread profile.
Test methods comprise: leak tightness under internal hydrostatic pressure, leak tightness under internal pneumatic pressure, integrity of fabricated fitting bodies or having an 'as cast' microstructure, resistance to pull out of joints to metallic tubes, resistance of joints with metallic tube to vibration, resistance of joints to static flexural force, leak tightness of joints under vacuum, the resistance of joints to temperature cycling, detecting non-pressed fitting ends, resistance to stress corrosion, detection of a carbon film on the surface of copper fittings, determination of mean depth of dezincification, resistance of joints to pressure cycling, disconnection and re-use, determining if the diameter and/or the length of engagement of a capillary end is/are within the specified tolerance, determining the minimum length of engagement of an integral solder or brazing ring socket having a formed groove.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for fittings with radial and axial press ends for use with plastics and multilayer pipes. The fitting ends have a nominal diameter from 10 mm to 160 mm. The fittings are designed for a service lifetime up to fifty.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastics and multilayer pipes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with plastics and multilayer pipes may also have flanged end connections according to EN 1092-3.
Press fittings for use with plastics and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845;
- supply systems for points of consumption with liquid fuels according to EN 12514.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for capillary fittings with short ends for brazing to copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2, etc. These fitting ends exist in two forms: end feed fittings and integral brazing ring fittings. For the purposes of joining copper tubes, the fitting ends have a nominal diameter from 14,7 mm to 159 mm. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings with short ends for brazing to copper tubes are used with brazing alloys in accordance with alloys specified in EN ISO 17672.
Not all copper alloys that can be used to manufacture fittings can be brazed and those that can be brazed may require different brazing techniques (guidance is provided in in EN 1254-20:2021, Annex A).
Fittings with short ends for capillary brazing may also have threaded end connections. These threaded ends exist with metallic and with non-metallic sealing elements. For the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 1/8" to 4".
Adaptor fittings for use with copper tubes may combine short ends for capillary brazing with fitting ends defined in the other parts of EN 1254.
Capillary fittings with short ends for brazing may also have flanged end connections according to EN 1092-3.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845;
- refrigeration systems;
- supply systems for points of consumption with liquid fuels according to EN 12514.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;- gas line systems with an operating pressure exceeding 0,5 bar for industrial installations and exceeding 5 bar for industrial and non-industrial installations according to EN 15001-1;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for push-fit fittings for the purpose of joining tubes of copper, plated copper, multilayer pipes and plastics pipes. The fitting ends have a nominal diameter from 6 mm to 54 mm. The fittings are designed for a service lifetime up to fifty years.
This document is applicable to push-fit fittings for joining one or more of the following tubes or pipes:
- copper tubes to EN 1057.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings may combine push-fit ends with fitting ends defined in the other parts of EN 1254.
Push-fit fittings for metallic tubes may also have flanged end connections according to EN 1092-3.
Push-fit fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for threaded fittings. These threaded ends exist with metallic and with non-metallic sealing elements for the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 3,175 mm (1/8") to 101,6 mm (4"). The threaded fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Threaded fittings may also have flanged end connections according to EN 1092-3.
Threaded fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, includingsystems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for fittings with ends for capillary soldering or capillary brazing for connecting with copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2 etc. For the purposes of joining copper tubes, the fitting ends have a nominal diameter from 6 mm to 108 mm. These fitting ends exist in three forms: end feed fittings, integral solder and integral brazing ring fitting ends. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings for soldering or brazing to copper tubes are used with solder alloys in accordance with alloys specified in EN ISO 9453 and brazing alloys in accordance with alloys specified in EN ISO 17672.
Adaptor fittings for use with copper tubes may combine capillary soldering or capillary brazing ends with fitting ends defined in the other parts of EN 1254.
Capillary fittings for soldering or brazing may also have flanged end connections according to EN 1092-3.
Capillary fittings for soldering or brazing may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845;
- refrigeration systems;
- supply systems for points of consumption with liquid fuels according to EN 12514.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- gas line systems with an operating pressure exceeding 0,5 bar for industrial installations and exceeding 5 bar for industrial and non-industrial installations according to EN 15001-1;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for compression fittings for connecting with copper tubes. Compression fittings exist with sealing elements - metallic and/or non-metallic - called non manipulative (commonly referenced as type A) and without sealing elements, called manipulative (commonly referenced as type B). For the purposes of joining copper tubes, the fitting ends have a nominal diameter from 6 mm to 108 mm. The compression fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Compression fitting ends, Type A, are used with copper tubes to EN 1057 in all material hardness conditions.
Compression fittings, Type A, will possibly require an internal support when used with R220 (annealed) copper tube and the manufacturer’s advice should be sought.
Compression fitting ends, Type B, are used with R220 (annealed) or R250 (half-hard) copper tube to EN 1057.
Compression fittings, Type B, may be used with R290 (hard) copper tube and the manufacturer’s advice should be sought.
Adaptor fittings for use with copper tubes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with copper tubes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with copper tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems.
b) drainage systems:
- fire protection systems including sprinkler systems according to EN 12845;
- supply systems for points of consumption with liquid fuels according to EN 12514.
c) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for press fittings including their elastomeric seals, for connecting with metallic tubes. The fitting ends have a nominal diameter from 6 mm to 108 mm. The press fittings are designed for a service lifetime up to fifty years.
This document is applicable to press fittings for joining one or more of the following tubes:
- copper tubes to EN 1057; and
- stainless steel tubes to EN 10312;
with wall thicknesses and tempers as specified by the manufacturer.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
Press fittings are used with tubes with wall thicknesses greater than or equal to the wall thickness given in Annex B, to ensure that tubes can withstand the radial pressing forces involved.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with copper tubes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with metallic tubes may also have flanged end connections according to EN 1092-3.
Press fittings for use with metallic tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot or cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845;
- supply systems for points of consumption with liquid fuels according to EN 12514.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for fittings with compression ends for use with plastics and multilayer pipes which are defined in the applicable pipe standard. For the purposes of joining plastics pipes, the fitting ends have a nominal diameter from 6 mm to 160 mm. The fittings are designed for a service lifetime up to fifty years.
The compression fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastics and multilayer pipes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with plastics and multilayer pipes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with plastics and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water, including systems according to EN 806;
- closed heating systems according to EN 12828;
- cooling systems;
- drainage systems;
- fire protection systems including sprinkler systems according to EN 12845.
b) gas applications (not valid for multilayer pipes):
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies dimensions, tolerances, internal and external surface characteristics and marking of welded fittings for the food and chemical industry.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This draft European Standard specifies the technical delivery requirements for seamless and welded butt welding fittings (elbows, concentric and eccentric reducers, equal and reducing tees, caps) made of carbon and alloy steel in two test categories which are intended for pressure purposes at room temperature, at low temperature or at elevated temperatures, and for the transmission and distribution of fluids and gases.
It specifies:
a) type of fittings;
1) type A: Butt-welding fittings with reduced pressure factor;
2) type B: Butt-welding fittings for use at full service pressure;
b) steel grades and their chemical compositions;
c) mechanical properties;
d) dimensions and tolerances;
e) requirements for inspection and testing;
f) inspection documents;
g) marking;
h) protection and packaging.
NOTE In the case of a harmonised supporting standard for materials, presumption of conformity to the ESRs is limited to technical data of materials in the standard and does not presume adequacy of the material to a specific item of equipment. Consequently it is essential that the technical data stated in the material standard be assessed against the design requirements of this specific item of equipment to verify that the ESRs of the PED are satisfied.
- Standard145 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for fittings with ends for capillary soldering or capillary brazing for connecting with copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2 etc. For the purposes of joining copper tubes, the fitting ends have a size range from 6 mm to 108 mm. These fitting ends exist in three forms: end feed fittings and integral solder and integral brazing ring fitting ends. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings for soldering or brazing to copper tubes are used with solder alloys in accordance with alloys specified in EN ISO 9453 and brazing alloys in accordance with alloys specified in EN ISO 17672.
Adaptor fittings for use with copper tubes may combine capillary soldering or capillary brazing ends with fitting ends defined in the other parts of EN 1254.
Capillary fittings for soldering or brazing may also have flanged end connections according to EN 1092-3.
Capillary fittings for soldering or brazing may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
- refrigeration systems;
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for threaded fittings. These threaded ends exist with metallic and with non-metallic sealing elements for the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 3,175 mm (1/8") to 101,6 mm (4"). The threaded fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Threaded fittings may also have flanged end connections according to EN 1092-3.
Threaded fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for fittings with radial and axial press ends for use with plastics and multilayer pipes. The fitting ends have a size range from 10 mm to 160 mm. The fittings are designed for a service lifetime up to fifty.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastic and multilayer pipes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with plastic and multilayer pipes may also have flanged end connections according to EN 1092-3.
Press fittings for use with plastic and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for press fittings including their elastomeric seals, for connecting with metallic tubes. The fitting ends have a size range from 6 mm to 108 mm. The press fittings are designed for a service lifetime up to fifty years.
This document is applicable to press fittings for joining one or more of the following tubes:
- copper tubes to EN 1057 and
- stainless steel tubes to EN 10312
with wall thicknesses and tempers as specified by the manufacturer.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
Press fittings are used with tubes with wall thicknesses greater than or equal to the wall thickness given in Annex B, to ensure that tubes can withstand the radial pressing forces involved.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with copper tubes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with metallic tubes may also have flanged end connections according to EN 1092-3.
Press fittings for use with metallic tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot or cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for push-fit fittings for the purpose of joining tubes of copper, plated copper, multilayer pipes and plastics pipes. The fitting ends have a size range from 6 mm to 54 mm. The fittings are designed for a service lifetime up to fifty years.
This document is applicable to push-fit fittings for joining one or more of the following tubes or pipes:
- copper tubes to EN 1057; copper composite according to UNI 11342, plastic and multilayer pipes covered by EN 15015.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings may combine push-fit ends with fitting ends defined in the other parts of EN 1254.
Push-fit fittings for metallic tubes may also have flanged end connections according to EN 1092-3.
Push-fit fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for fittings with compression ends for use with plastic and multilayer pipes which are defined in the applicable pipe standard. For the purposes of joining plastics pipes, the fitting ends have a size range from 10 mm to 160 mm. The fittings are designed for a service lifetime up to fifty years.
The compression fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This European Standard applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastic and multilayer pipes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with plastic and multilayer pipes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with plastic and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- Hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications (not valid for multilayer pipes):
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This document contains definitions, thread dimension, reference data (minimum bore), supporting information (assembling instructions) and describes the test methods referenced by other parts of the EN 1254 series.
Thread dimensions comprise: wall thickness at threaded portions of fittings, dimensions of tail pipe ends for swivel fittings, dimensions of gas union connectors, thread dimensions and thread profile.
Test methods comprise: leak tightness under internal hydrostatic pressure, leak tightness under internal pneumatic pressure, resistance of joints to static flexural strength, resistance to pull out of joints, leak tightness of joints under vacuum, the resistance of joints to temperature cycling, resistance of joints with metallic tube to vibration, integrity of fabricated fitting bodies or having an 'as cast' microstructure, resistance to stress corrosion, detection of a carbon film on the surface of copper fittings, determination of mean depth of dezincification, resistance of joints to pressure cycling, disconnection and re-use, determining if the diameter and/or the length of engagement of a capillary end is/are within the specified tolerance, determining the minimum length of engagement of an integral solder or brazing ring socket having a formed groove.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for compression fittings for connecting with copper tubes. Compression fittings exist with sealing elements - metallic and/or non-metallic - called non manipulative (commonly referenced as type A) and without sealing elements, called manipulative (commonly referenced as type B). For the purposes of joining copper tubes, the fitting ends have a size range from 6 mm to 108 mm. The compression fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Compression fitting ends, Type A, are used with copper tubes to EN 1057 in all material hardness conditions.
NOTE 1 Compression fittings, Type A, will possibly require an internal support when used with R220 (annealed) copper tube and the manufacturer’s advice should be sought.
Compression fitting ends, Type B, are used with R220 (annealed) or R250 (half-hard) copper tube to EN 1057.
NOTE 2 Compression fittings, Type B, may be used with R290 (hard) copper tube and the manufacturer’s advice should be sought.
Adaptor fittings for use with copper tubes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with copper tubes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with copper tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for capillary fittings with short ends for brazing to copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2, etc. These fitting ends exist in two forms: end feed fittings and integral brazing ring fittings. For the purposes of joining copper tubes, the fitting ends have a size range from 14,7 mm to 159 mm. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings with short ends for brazing to copper tubes are used with brazing alloys in accordance with alloys specified in EN ISO 17672.
Not all copper alloys that can be used to manufacture fittings can be brazed and those that can be brazed may require different brazing techniques (guidance is provided in in prEN1254-20:2019, Annex A).
Fittings with short ends for capillary brazing may also have threaded end connections. These threaded ends exist with metallic and with non-metallic sealing elements. For the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 1/8" to 4".
Adaptor fittings for use with copper tubes may combine short ends for capillary brazing with fitting ends defined in the other parts of EN 1254.
Capillary fittings with short ends for brazing may also have flanged end connections according to EN 1092-3.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
- refrigeration systems.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods applicable to factory applied internal lining made of thermoplastic acid modified polyolefin (TMPO) for the heavy duty corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969. This document also applies to pipes with only socket and spigot ends coated with TMPO. Fittings and accessories are covered separately by EN 14901-2.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes according to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This document is not applicable to ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping, etc. can influence the corrosion protection properties. Those job steps are intended to be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this document.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for thermoplastic modified polyolefin (TMPO) lining of pipes and fittings.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This European Standard does not cover ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping etc. may influence the corrosion protection properties. Those job steps shall be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this European Standard.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines the requirements and test methods for factory applied thermoplastic acid modified polyolefin (TMPO) coatings used for the protection of ductile iron fittings and accessories according to EN 545, EN 598, EN 969, EN 12842 and EN 14525:
- conveying water (e.g. potable water, raw water, …) at operating temperature up to 50 °C; or
- conveying waste water at operating temperature up to 45 °C; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in D.2.3 of EN 545:2010.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for factory made thermally insulated bonded fitting assemblies for hot water networks in accordance with EN 13941 1, comprising a steel service fitting, rigid polyurethane foam thermal insulation and a casing of polyethylene.
The fitting assembly could also include the following additional elements: measuring wires, spacers and diffusion barriers.
This document covers the following fitting assemblies: bend, tee, reducer, single use compensator and anchor.
This document applies to fitting assemblies with a minimum design pressure of 1,6 MPa (overpressure).
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
To allow ductile iron pipe manufacturers and users of the product to apply TMPO linings and thereby comply with the relevant requirements of EN 545, EN 545, EN 969. This demonstrates innovation according to Annex I, by the use of non-traditional coating systems offering environmental and economic benefits. The TMPO linings meet the criteria expressed in EN 14901, except for those pertinent to fusion bonded epoxy chemistry. The linings are being used in other parts of the world eg Australia and New Zealand and have been incorporated in the recent AWWA C116/A21.16-15 publication. The current status for TMPO linings in EU amounts to a barrier to trade and does not support SME’s involved in the manufacture, lining and application of the material that offers human health benefits, as highlighted in the Annex I and II.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for factory made thermally insulated bonded fitting assemblies for hot water networks in accordance with prEN 13941-1, comprising a steel service fitting, rigid polyurethane foam insulation and a casing of polyethylene.
The fitting assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.
This document covers the following fitting assemblies: bend, tee, reducer, single use compensator and anchor.
This document applies to fitting assemblies with a minimum design pressure of 16 bar (overpressure).
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report contains the sanitary characteristics and test methods applicable to those factory applied lining, coating and jointing materials of ductile iron pipes and fittings conforming to EN 545 which are in contact with water intended for human consumption for use at operating temperatures up to 50 °C. Ductile cast iron itself is not in direct contact with the conveyed water therefore no characteristics in respect to the sanitary behaviour are necessary. As ductile cast iron is impermeable against diffusion of organic substances the water quality is maintained in service. Different surface/volume ratios are used in the tests for pipes, fittings and joints to reflect the different impact of their surface areas exposed to the water in the overall pipeline.
- Technical report16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to pipes and fittings of longitudinally welded stainless steel pipes with spigot and socket for waste water systems and specifies dimensions and tolerances for pipes, fittings and pipe connectors and establishes a system of designations for the different pipe and fitting types that conform to the stated requirements.
This part of EN 1124 is only valid in connection with EN 1124 1.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, dimensions and tolerances for pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket used for vacuum drainage systems inside and outside buildings and for gravity and vacuum drainage systems on ships and floating maritime structures ) :
- above freeboard deck as long as the heeling is taken into account in the event of damage when installed above freeboard deck on passenger ships;
- inside a watertight compartment below freeboard deck;
- with direct connection to the outboard (not permitted below freeboard deck);
- inside tanks as long as these are not filled with foreign media and are not cargo tanks.
On well-anchored maritime structures, this European Standard applies to pipes and fittings of longitudinally welded stainless steel pipe with spigot and socket used in drainage systems in the accommodation area.
Pipes and fittings according to this European Standard may also be used in central vacuum cleaning installations, in vacuum suction lifting installations, in chip transporting installations and in other waste water and process pipes as long as the media to be discharged do not damage the components or the health and safety of the personnel.
For other pipes, this European Standard only applies if agreed with the relevant operators and following prior consultation with the manufacturer.
This European Standard contains a designation system for the different types of pipes and fittings for easy identification of each component.
This European Standard is only applicable in conjunction with EN 1124-1.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, dimensions and tolerances for pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket used for vacuum drainage systems inside and outside buildings and for gravity and vacuum drainage systems on ships and floating maritime structures1) - above freeboard deck as long as the heeling is taken into account in the event of damage when installed above freeboard deck on passenger ships; - inside a watertight compartment below freeboard deck; - with direct connection to the outboard (not permitted below freeboard deck); - inside tanks as long as these are not filled with foreign media and are not cargo tanks. On well-anchored maritime structures, this European Standard applies to pipes and fittings of longitudinally welded stainless steel pipe with spigot and socket used in drainage systems in the accommodation area. pipes as long as the media to be discharged do not damage the components or the health and safety of the personnel. For other pipes, this European Standard only applies if agreed with the relevant operators and following prior consultation with the manufacturer. This European Standard contains a designation system for the different types of pipes and fittings for easy identification of each component. This European Standard is only applicable in conjunction with EN 1124-1.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report applies to all water and sewerage applications of ductile iron pipe systems and provides a structure on how to identify and consider environmental aspects and potential environmental impacts of ductile iron pipe systems throughout their life cycle.
This Technical Report gives guidance on how the life cycle of ductile iron pipelines should be considered in accordance with EN ISO 14044. This Technical Report also includes health and safety aspects related to the production, use and recycling of ductile iron pipe systems.
- Technical report9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron fittings, ductile iron and mild steel couplings and flange adaptors and their joints to be used with poly(vinyl chloride) (PVC-U) pipes or polyethylene (PE) pipes. It is in conformity with EN 1452-1 to -5, ENV 1452-6 and -7 and EN 12201-1 to -5 respectively, for the construction of pipelines:
- to convey water (e.g. water intended for human consumption);
- with or without pressure;
- to be installed below or above ground, inside or outside buildings.
This European Standard is not intended to cover sewerage applications, where additional requirements may be necessary.
This European Standard is applicable to fittings which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for PE and PVC-U pipes with fluid temperatures between 0°C and 25°C, excluding frost, and for pressures up to 16 bar (PFA). For higher temperatures (up to 45°C for PVC-U or 40°C for PE) the PFA is derated as given in EN 1452 and EN 12201;
- not intended for use in areas subjected to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures. Temperature limitations and pressure limitations are those coming from the PVC-U or PE pipes.
This European Standard covers ductile iron fittings, couplings and flange adaptors cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
As long as no equivalent European Standard exists for mild steel accessories, this European Standard also covers couplings and flange adaptors for use with PVC-U and PE pipes which are fabricated partly or entirely from mild steel as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings. It also gives minimum performance requirements for all components, including restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard.
This European Standard does not cover fittings, couplings and flange adaptors intended to be used with different pipe materials other than PVC-U and PE.
NOTE 2 Fittings, couplings and flange adaptors complying with the requirements of this European Standard for PVC-U also usually meet the requirements for PVC-O and PVC-A pipes. Where this is not the case, the manufacturer is expected to declare this in the relevant literature.
NOTE 3 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron fittings, ductile iron and mild steel couplings and flange adaptors and their joints to be used with poly(vinyl chloride) (PVC-U) pipes or polyethylene (PE) pipes. It is in conformity with EN 1452-1 to -5, ENV 1452-6 and - 7 and EN 12201-1 to -5 respectively, for the construction of pipelines: - to convey water (e.g. water intended for human consumption); - with or without pressure; - to be installed below or above ground, inside or outside buildings. This European Standard is not intended to cover sewerage applications, where additional requirements may be necessary. This European Standard is applicable to fittings which are: - manufactured with socketed, flanged or spigot ends; - supplied externally and internally coated; - suitable for PE and PVC-U pipes with fluid temperatures between 0°C and 25°C, excluding frost, and for pressures up to 16 bar (PFA). For higher temperatures (up to 45°C for PVC-U or 40°C for PE) the PFA is derated as given in EN 1452 and EN 12201; - not intended for use in areas subjected to reaction to fire regulations. This European Standard covers ductile iron fittings, couplings and flange adaptors cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm. As long as no equivalent European Standard exists for mild steel accessories, this European Standard also covers couplings and flange adaptors for use with PVC-U and PE pipes which are fabricated partly or entirely from mild steel as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm. This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings. It also gives minimum performance requirements for all components, including restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard. This European Standard does not cover fittings, couplings and flange adaptors intended to be used with different pipe materials other than PVC-U and PE.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines outside buildings:
- to convey different types of water (e.g. raw water, treated water, re-used water) for all types of applications (e.g. water intended for human consumption, for fire protection, for snow making, for irrigation, for hydro-electricity etc.);
- with or without pressure;
- to be installed below or above ground.
This European Standard is applicable to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for fluid temperatures between 0 °C and 50 °C, excluding frost;
- not intended for use in areas subject to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.
This European Standard covers pipes and fittings cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints and accessories, in a size range extending from DN 40 to DN 2 000, inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard.
In addition, reference is made to the performance requirements of couplings, flange adaptors and saddles manufactured for use with ductile iron pipes and fittings.
NOTE 2 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard93 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard + National Annex and/or Foreword96 pagesForeword and/or annex in Slovenian language, body of the standard in English languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines outside buildings: - to convey different types of water (e.g. raw water, treated water, re-used water) for all types of applications (e.g. water intended for human consumption, for fire protection, for snow making, for irrigation, for hydro-electricity etc.); - with or without pressure; - to be installed below or above ground. This European Standard is applicable to pipes, fittings and accessories which are: - manufactured with socketed, flanged or spigot ends; - supplied externally and internally coated; - suitable for fluid temperatures between 0 °C and 50 °C, excluding frost; - not intended for use in areas subject to reaction to fire regulations. This does not preclude special arrangements for the products to be used at higher temperatures. This European Standard covers pipes and fittings cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints and accessories, in a size range extending from DN 40 to DN 2 000, inclusive. This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard. In addition, reference is made to the minimum performance requirements of couplings, flange adaptors and saddles manufactured for use with ductile iron pipes and fittings.
- Standard93 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard + National Annex and/or Foreword96 pagesForeword and/or annex in Slovenian language, body of the standard in English languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints used for the construction of external pipelines:
- to convey air or combustible gases (e.g. natural gas or town gas) at pressures up to 16 bar;
- to be installed below or above ground.
NOTE 1 A combustible gas is a gas or any fuel that is in gaseous state at a temperature of 15 °C at a pressure of 1 bar.
This European Standard applies to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- normally delivered externally and internally coated;
- suitable for gas temperatures between - 15 °C and 50 °C.
This European Standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 600 inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shape are outside the scope of this European Standard.
NOTE 2 In this European Standard, all pressures are relative pressures expressed in bars (100 kPa = 1 bar).
- Standard73 pagesEnglish languagesale 10% offe-Library read for1 day
EN 598 specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- operating without pressure (gravity sewerage), or with positive or negative pressure;
- to be installed below or above ground;
- to convey surface water, domestic waste water and certain types of industrial effluents, either in separate systems or in combined systems.
This technical report:
- explains in more detail the process of testing for the performance tests;
- explains in more detail the benefits of high alumina cement lining;
- explains in more detail the definitions of the different types/levels of attestation to enable customers to ensure their requirements are fulfilled;
- explains in more detail the ways of certification of conformity with EN 598 for a reliable evaluation of the performance of products;
- explains in more detail CE marking and its relevance i.e. the CE mark is not a mark of conformity with a standard but only a self-declaration concerning the CPD essential requirements.
In order to make the use of this Technical Report easier, the clauses of this document refer to the
corresponding clause numbers in EN 598.
- Technical report11 pagesEnglish languagesale 10% offe-Library read for1 day
- 1 (current)
- 2
- 3
- 4
- 5