Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals

SCOPE
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.
1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.Note 1
This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) without leakage when tested in accordance with Section . Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.
The following precautionary caveat pertains only to the test methods portion, Section , of this specification:  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  For a specific warning statement, see .

General Information

Status
Historical
Publication Date
31-Jan-2006
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1478-06 - Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1478 – 06
Standard Specification for
Storm Drain Resilient Connectors Between Reinforced
1
Concrete Storm Sewer Structures, Pipes, and Laterals
This standard is issued under the fixed designation C 1478; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope A 493 Specification for Stainless Steel Wire and Wire Rods
for Cold Heading and Cold Forging
1.1 This specification covers the minimum performance and
A 666 Specification for Annealed or Cold-Worked Austen-
material requirements for resilient connectors used for connec-
itic Stainless Steel Sheet, Strip, Plate, and Flat Bar
tions between precast reinforced concrete storm sewer struc-
C 478 Specification for Precast Reinforced Concrete Man-
tures conforming to Specification C 478 and pipes, and be-
hole Sections
tween precast reinforced concrete pipe and laterals for storm
C 822 Terminology Relating to Concrete Pipe and Related
drainage systems.
Products
1.1.1 These connectors are designed to prevent soil migra-
D 395 Test Methods for Rubber Property—Compression
tion between the pipe and storm sewer structure, and between
Set
the pipe and lateral.
D 412 Test Methods for Vulcanized Rubber and Thermo-
1.2 The values stated in inch-pound units are to be regarded
plastic Elastomers—Tension
as standard. The values given in parentheses are for informa-
D 471 Test Method for Rubber Property—Effect of Liquids
tion only.
D 543 Practices for Evaluating the Resistance of Plastics to
NOTE 1—This specification covers the design, material, and perfor-
Chemical Reagents
mance of the resilient connection only. Connections covered by this
D 573 Test Method for Rubber—Deterioration in an Air
specification are adequate for hydrostatic pressures up to 6 psi (14 ft)
Oven
without leakage when tested in accordance with Section 7. Infiltration
D 624 Test Method for Tear Strength of Conventional
quantities for an installed system are dependent upon many factors other
than the connections between storm sewer structures and pipe, and Vulcanized Rubber and Thermoplastic Elastomers
allowable quantities must be covered by other specifications and suitable
D 746 Test Method for Brittleness Temperature of Plastics
testing of the installed pipeline and system.
and Elastomers by Impact
D 883 Terminology Relating to Plastics
1.3 The following precautionary caveat pertains only to the
D 1171 Test Method for Rubber Deterioration—Surface
test methods portion, Section 7, of this specification: This
Ozone Cracking Outdoors or Chamber (Triangular Speci-
standard does not purport to address all of the safety concerns,
mens)
if any, associated with its use. It is the responsibility of the user
D 1566 Terminology Relating to Rubber
of this standard to establish appropriate safety and health
D 2240 Test Method for Rubber Property—Durometer
practices and determine the applicability of regulatory limita-
Hardness
tions prior to use. For a specific warning statement, see 7.2.4.
3. Terminology
2. Referenced Documents
2
3.1 Definitions:
2.1 ASTM Standards:
3.1.1 Terms relating to plastics and rubber shall be as
defined in Terminologies D 883 and D 1566, respectively.
3.1.2 Terms relating to precast concrete pipe, manholes, and
1
This specification is under the jurisdiction of ASTM Committee C13 on
related products shall be as defined in Terminology C 822.
Concrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholes
3.2 Definitions of Terms Specific to This Standard:
and Specials.
3.2.1 connector—the entire assembly, including resilient
Current edition approved Feb. 1, 2006. Published February 2006. Originally
approved in 2000. Last previous edition approved in 2000 as C 1478 – 00.
seals and metallic or nonmetallic mechanical devices, if any,
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
used therein.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3.2.2 lateral—the small diameter pipe connected to the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. main line pipe.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1478–06
3.2.3 pipe—the inlet or outlet pipe connected to the man- the pipe. Resilient filler rings may be used between the pipe
hole. and the connector to provide a seal. Whichever design is used,
3.2.4 pipe stub—a short section of pipe installed in the it shall be capable of maintaining a resilient, hydrostatic seal
structure as an inlet
...

Questions, Comments and Discussion