Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System

ABSTRACT
This specification covers a single component protective roof coating composed of solvent-borne moisture curing urethane elastomeric polymer, to which various pigments or other additives have been added to give the required physical properties. The product, as manufactured, shall be in liquid form for application to spray polyurethane foam (SPF) surfaces by brushing, rolling, or spraying. However, guidance for its application is not addressed here. Coatings shall be tested and conform accordingly to specified liquid property requirements as to viscosity, and volume and weight of solids. Dry films shall also adhere to the following physical property requirements, when tested as appropriate: initial percent elongation at break; initial tensile strength at maximum stress; final percent elongation at break after accelerated weathering; permeance; water absorption; adhesion; fungi resistance; tear resistance; and low temperature flexibility.
SCOPE
1.1 This specification covers a single component, moisture cured, elastomeric urethane polymer coating used as a protective coating for spray polyurethane foam roofing systems.
1.2 This specification does not provide guidance for application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 The following precautionary caveat pertains only to the test method portions, Sections 5 and 6.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D6947-07 - Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D6947 −07
StandardSpecification for
Liquid Applied Moisture Cured Polyurethane Coating Used
1
in Spray Polyurethane Foam Roofing System
This standard is issued under the fixed designation D6947; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D903Test Method for Peel or Stripping Strength of Adhe-
sive Bonds
1.1 This specification covers a single component, moisture
D1079Terminology Relating to Roofing and Waterproofing
cured, elastomeric urethane polymer coating used as a protec-
D1644Test Methods for Nonvolatile Content of Varnishes
tive coating for spray polyurethane foam roofing systems.
D1653Test Methods for Water Vapor Transmission of Or-
1.2 This specification does not provide guidance for appli-
ganic Coating Films
cation.
D2196Test Methods for Rheological Properties of Non-
1.3 The values stated in SI units are to be regarded as Newtonian Materials by Rotational (Brookfield type)
standard. The values given in parentheses are for information
Viscometer
only. D2697Test Method for Volume Nonvolatile Matter in Clear
or Pigmented Coatings
1.4 The following precautionary caveat pertains only to the
D2370Test Method for Tensile Properties of Organic Coat-
test method portions, Sections 5 and 6.
ings
1.5 This standard does not purport to address all of the
D4798Practice for Accelerated Weathering Test Conditions
safety concerns, if any, associated with its use. It is the
and Procedures for Bituminous Materials (Xenon-Arc
responsibility of the user of this standard to establish appro-
Method)
priate safety and health practices and determine the applica-
G21Practice for Determining Resistance of Synthetic Poly-
bility of regulatory requirements prior to use.
meric Materials to Fungi
2. Referenced Documents
3. Terminology
2
2.1 ASTM Standards:
3.1 Fordefinitionsoftermsspecifictothisstandard,referto
D16TerminologyforPaint,RelatedCoatings,Materials,and
Terminologies D16 and D1079.
Applications
D412TestMethodsforVulcanizedRubberandThermoplas-
4. Materials and Manufacture
tic Elastomers—Tension
D471Test Method for Rubber Property—Effect of Liquids
4.1 Composition—Theproduct,asmanufactured,shallbein
D522Test Methods for Mandrel Bend Test of Attached
liquid form for application to spray polyurethane foam (SPF)
Organic Coatings
surfacesbybrushing,rolling,orspraying.Theproductshallbe
D562Test Method for Consistency of Paints Measuring
composed of a solvent-borne moisture curing urethane elasto-
KrebsUnit(KU)ViscosityUsingaStormer-TypeViscom-
meric polymer, to which various pigments or other additives
eter
have been added to give the required physical properties.
D624Test Method for Tear Strength of Conventional Vul-
4.2 Physical Properties—Although the product is supplied
canized Rubber and Thermoplastic Elastomers
as a liquid, its performance is based on the functional proper-
ties of the dried material in film form. The coating is formed
1
This specification is under the jurisdiction of ASTM Committee D08 on into a film fully adhered to the substrate surface.
RoofingandWaterproofingandisthedirectresponsibilityofSubcommitteeD08.06
on Spray Polyurethane Foam Roof Systems.
5. Physical Properties
Current edition approved May 1, 2007. Published May 2007. Originally
approved in 2006. Last previous edition approved in 2006 as D6947–06. DOI:
5.1 The liquid coating shall comply with physical property
10.1520/D6947-07.
2 requirements in Table 1.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.2 The film shall comply with physical property require-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. ments in Table 2.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6947−07
2
TABLE 1 Liquid Property Requirements NOTE 1—Based on the irradiance level of 0.35 W/(m · nm) at 340 nm
specified in Practice D4798, the exposure time required to accumulate the
Physical
ASTM Requirements
radiant energy specified in 6.4 is 1000 h.
Properties
Viscosity D562 90 to 110 KU
6.5 Permeance (Test Methods D1653, Procedure B)—A0.5
D2196 12 to 85 Pa·s
mm (20 mils) 6 10% film shall be used.
Volume Solids D2697 Greater than 65 %
6.5.1 Test Conditions: 23 6 2°C (73.4 6 3.6°F).
Weight Solids D1644 As listed by Manufacturer
6.5.2 Test is run in the inverted position with water in
contact with the film.
TABLE 2 Film Physical Property Requirements for Polyurethane
6.5.3 Value is re
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.