Standard Specification for Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers

ABSTRACT
This specification covers requirements, test methods, materials, and marking for polypropylene (PP), open bottom, buried chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways. Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. They are manufactured with integral feet that provide base support. They may include perforations to enhance water flow and must meet test requirements for arch stiffness, flattening, and accelerated weathering. The successful performance of the product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser.
SCOPE
1.1 This specification covers requirements, test methods, materials, and marking for polypropylene (PP), open bottom, buried chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways.
1.2 Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. Chambers are manufactured with integral feet that provide base support. Chambers may include perforations to enhance water flow. Chambers must meet test requirements for arch stiffness, flattening, and accelerated weathering.  
1.3 Analysis and experience have shown that the successful performance of this product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address water quality issues or hydraulic performance requirements associated with its use. It is the responsibility of the user to ensure that appropriate engineering analysis is performed to evaluate the water quality issues and hydraulic performance requirements for each installation.
1.6 The following safety hazards caveat pertains only to the test method portion, Section 6, of this specification:  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2009
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2418-09 - Standard Specification for Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2418-09 - Standard Specification for Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F2418 – 09
Standard Specification for
Polypropylene (PP) Corrugated Wall Stormwater Collection
1
Chambers
This standard is issued under the fixed designation F2418; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
1. Scope* if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health
1.1 This specification covers requirements, test methods,
practices and determine the applicability of regulatory limita-
materials, and marking for polypropylene (PP), open bottom,
tions prior to use.
buried chambers of corrugated wall construction used for
collection, detention, and retention of stormwater runoff. Ap-
2. Referenced Documents
plications include commercial, residential, agricultural, and
2
2.1 ASTM Standards:
highwaydrainage,includinginstallationunderparkinglotsand
D256 Test Methods for Determining the Izod Pendulum
roadways.
Impact Resistance of Plastics
1.2 Chambers are produced in arch shapes with dimensions
D618 Practice for Conditioning Plastics for Testing
based on chamber rise, chamber span, and wall stiffness.
D638 Test Method for Tensile Properties of Plastics
Chambersaremanufacturedwithintegralfeetthatprovidebase
D790 Test Methods for Flexural Properties of Unreinforced
support. Chambers may include perforations to enhance water
and Reinforced Plastics and Electrical Insulating Materials
flow. Chambers must meet test requirements for arch stiffness,
D1600 Terminology for Abbreviated Terms Relating to
flattening, and accelerated weathering.
Plastics
1.3 Analysis and experience have shown that the successful
D2122 Test Method for Determining Dimensions of Ther-
performance of this product depends upon the type and depth
moplastic Pipe and Fittings
of bedding and backfill, and care in installation. This specifi-
D2412 Test Method for Determination of External Loading
cation includes requirements for the manufacturer to provide
Characteristics of Plastic Pipe by Parallel-Plate Loading
chamber installation instructions to the purchaser.
D2990 Test Methods for Tensile, Compressive, and Flex-
1.4 The values stated in inch-pound units are to be regarded
ural Creep and Creep-Rupture of Plastics
as standard. The values given in parentheses are mathematical
D4101 Specification for Polypropylene Injection and Extru-
conversions to SI units that are provided for information only
sion Materials
and are not considered standard.
D4329 Practice for Fluorescent UV Exposure of Plastics
1.5 This standard does not purport to address water quality
D6992 Test Method for Accelerated Tensile Creep and
issues or hydraulic performance requirements associated with
Creep-Rupture of Geosynthetic Materials Based on Time-
its use. It is the responsibility of the user to ensure that
Temperature Superposition Using the Stepped Isothermal
appropriate engineering analysis is performed to evaluate the
Method
water quality issues and hydraulic performance requirements
F412 Terminology Relating to Plastic Piping Systems
for each installation.
2.2 AASHTO Specification:
1.6 The following safety hazards caveat pertains only to the
Section 12 Buried Structures and Tunnel Liners, 12.12
test method portion, Section 6, of this specification: This
3
Thermoplastic Pipes
standard does not purport to address all of the safety concerns,
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Piping Systems and is the direct responsibility of Subcommittee F17.65 on Land Standards volume information, refer to the standard’s Document Summary page on
Drainage. the ASTM website.
3
Current edition approved May 1, 2009. Published May 2009. Originally AASHTO LRFD Bridge Design Specifications-Dual Units, Third Edition,
approved in 2004. Last previous edition approved in 2005 as F2418-05. DOI: 2004. Available from American Association of State Highway and Transportation
10.1520/F2418-09. Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F2418 – 09
3. Terminology 3.1.12 span—the horizontal distance from the interior of
one sidewall valley element to the interior of the other sidewall
3.1 Definitions: Definitions used in th
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation: F2418 – 09
Standard Specification for
Polypropylene (PP) Corrugated Wall Stormwater Collection
1
Chambers
This standard is issued under the fixed designation F2418; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements, test methods, materials, and marking for polypropylene (PP), open bottom, buried
chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include
commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways.
1.2 Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. Chambers
are manufactured with integral feet that provide base support. Chambers may include perforations to enhance water flow.
Chambers must meet test requirements for arch stiffness, flattening, and accelerated weathering.
1.3 Analysis and experience have shown that the successful performance of this product depends upon the type and depth of
bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber
installation instructions to the purchaser.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address water quality issues or hydraulic performance requirements associated with its
use. It is the responsibility of the user to ensure that appropriate engineering analysis is performed to evaluate the water quality
issues and hydraulic performance requirements for each installation.
1.6 The following safety hazards caveat pertains only to the test method portion, Section 6, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D256 Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics
D618 Practice for Conditioning Plastics for Testing
D638 Test Method for Tensile Properties of Plastics
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2990 Test Methods for Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics
D4101 Specification for Polypropylene Injection and Extrusion Materials
D4329 Practice for Fluorescent UV Exposure of Plastics
D6992 Test Method for Accelerated Tensile Creep and Creep-Rupture of Geosynthetic Materials Based on Time-Temperature
Superposition Using the Stepped Isothermal Method
F412 Terminology Relating to Plastic Piping Systems
2.2 AASHTO Specification:
3
Section 12 Buried Structures and Tunnel Liners, 12.12 Thermoplastic Pipes
1
ThisspecificationisunderthejurisdictionofASTMCommitteeF17onPlasticPipingSystemsandisthedirectresponsibilityofSubcommitteeF17.65onLandDrainage.
Current edition approved May 1, 2009. Published May 2009. Originally approved in 2004. Last previous edition approved in 2005 as F2418-05. DOI: 10.1520/F2418-09.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
AASHTO LRFD Bridge Design Specifications-Dual Units, Third Edition, 2004. Available from American Association of State Highway and Transportation Officials
(AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.