Standard Test Method for Determination of a Volatile Distillate Fraction of Cold Asphalt Mixtures

SIGNIFICANCE AND USE
This test method is used for determining the amount of a temperature specific volatile distillate fraction in cold mix asphalt mixtures.
SCOPE
1.1 This test method covers the determination, by direct measurement, of the ambient to 500°F (260°C) volatile distillate fraction of cold mix asphalt mixtures.
1.2 A precision and bias statement for the Standard has not been developed since this test method is used for research purposes or information only. Therefore this Standard should not be used for acceptance or rejection of a material for purchasing purposes.
1.3 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Dec-2006
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6627-01(2006) - Standard Test Method for Determination of a Volatile Distillate Fraction of Cold Asphalt Mixtures
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D6627–01(Reapproved 2006)
Standard Test Method for
Determination of a Volatile Distillate Fraction of Cold
Asphalt Mixtures
This standard is issued under the fixed designation D6627; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Apparatus
1.1 This test method covers the determination, by direct 4.1 AVertical Cylindrical Metal Still, similar to that used in
measurement, of the ambient to 500°F (260°C) volatile distil- Test Methods D244, having a faced flange at the top to which
late fraction of cold mix asphalt mixtures. theheadistightlyattachedbymeansofaclamp.Theheadshall
1.2 A precision and bias statement for the Standard has not be of a metal, preferably copper or brass, and shall be provided
been developed since this test method is used for research with a tubular opening of 25 mm (1 in.) in inside diameter and
purposes or information only. Therefore this Standard should an additional tubular opening of 13 mm ( ⁄2 in.) in inside
not be used for acceptance or rejection of a material for diameter. Threaded into the 25 mm (1 in.) tubular opening is a
purchasing purposes. stainless steel or brass fitting connected firmly to a ground
1.3 The values stated in inch-pound units are to be regarded glass joint by means of flexible stainless steel or glass tubing.
as the standard. The SI units given in parentheses are for Inserted into the 13 mm ( ⁄2 in.) tubular opening is a metal
information only. thermometer with a range of 93 to 538°C (200 to 1000°F)
1.4 This standard does not purport to address all of the extending 125 mm (5 in.) into the metal still and firmly
safety concerns, if any, associated with its use. It is the connected by means of a graphite ferrule compression fitting.
responsibility of the user of this standard to establish appro- 4.2 Condenser, of the water-cooled reflux glass-tube type,
priate safety and health practices and determine the applica- havingacondenserjacketnotlessthan400mm(15 ⁄4 in.)long
3 1
bility of regulatory limitations prior to use. with an inner tube 9.5 to 13 mm ( ⁄8 to ⁄2 in.) in the outside
diameter.The end of the condenser inserted in the ground glass
2. Referenced Documents
joint shall be ground off at an angle of 30° from the vertical
2.1 ASTM Standards:
axis of the condenser. For mixtures with very volatile solvents,
D244 Test Methods and Practices for Emulsified Asphalts it may be necessary to supplement this water-cooled condenser
D979 Practice for Sampling Bituminous Paving Mixtures
with a second water-cooled condenser of approximately the
D1461 Test Method for Moisture or Volatile Distillates in same dimensions.
Bituminous Paving Mixtures
4.3 CollectionFlask, cylinder of well-annealed glass having
D4753 Guide for Evaluating, Selecting, and Specifying a capacity of 100 mL graduated with divisions of 0.1 mL and
Balances and Standard Masses for Use in Soil, Rock, and
attached to the condenser(s) by means of a well-annealed glass
Construction Materials Testing bend. The glass bend attaching the condenser to the graduated
cylinder is secured by ground glass joints on either end and
3. Significance and Use
vented witha3mm( ⁄8 in.) vent on top of the bend directly
3.1 This test method is used for determining the amount of
above the graduated cylinder to prevent pressure in the
a temperature specific volatile distillate fraction in cold mix
apparatus. The collection flask is submerged to the top of the
asphalt mixtures.
gradations in an ice bath.
4.4 Distillation Liquid, 40 mL of distilled water.
4.5 Heating Device, of high temperature electrical heating
This test method is under the jurisdiction of ASTM Committee D04 on Road
and Paving Materials and is the direct responsibility of Subcommittee D04.27 on tape wrapped around the entire still and the connecting tubing
Cold Mix Asphalts.
between the still and condenser.Avariable voltage transformer
Current edition approved Dec. 15, 2006. Published December 2006. Originally
connected to the heating tape is used to control the rate of
approved in 2001. Last previous edition approved in 2001 as D6627 – 01. DOI:
temperature rise to approximately 5°C (10°F) per minute.
10.1520/D6627-01R06.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Insulate the entire still, including the connecting tubing from
contact ASTM Customer Ser
...

Questions, Comments and Discussion