Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)

SCOPE
1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.
1.2 This specification is the metric counterpart of Specification C 76.
Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
Note 2—Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C 655M).

General Information

Status
Historical
Publication Date
31-Jan-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C76M-05 - Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: C 76M – 05
METRIC
Standard Specification for
Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
1
[Metric]
This standard is issued under the fixed designation C 76M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope A 615/A 615M Specification for Deformed and Plain
Billet-Steel Bars for Concrete Reinforcement
1.1 This specification covers reinforced concrete pipe in-
C33 Specification for Concrete Aggregates
tended to be used for the conveyance of sewage, industrial
C 150 Specification for Portland Cement
wastes, and storm water, and for the construction of culverts.
C 309 Specification for Liquid Membrane-Forming Com-
1.2 This specification is the metric counterpart of Specifi-
pounds for Curing Concrete
cation C 76.
C 497M Test Methods for Concrete Pipe, Manhole Sec-
NOTE 1—This specification is a manufacturing and purchase specifica-
tions, or Tile [Metric]
tion only, and does not include requirements for bedding, backfill, or the
C 595 Specification for Blended Hydraulic Cements
relationship between field load condition and the strength classification of
C 618 Specification for Coal Fly Ash and Raw or Calcined
pipe. However, experience has shown that the successful performance of
Natural Pozzolan for Use as a Mineral Admixture in
this product depends upon the proper selection of the class of pipe, type
Concrete
of bedding and backfill, controlled manufacture in the plant, and care and
installation conforms to the construction specifications. The owner of the
C 655M Specification for Reinforced Concrete D-Load
reinforced concrete pipe specified herein is cautioned that he must
Culvert, Storm Drain, and Sewer Pipe [Metric]
correlate the field requirements with the class of pipe specified and
C 822 Terminology Relating to Concrete Pipe and Related
provide inspection at the construction site.
Products
NOTE 2—Attention is called to the specification for reinforced concrete
C 1116 Specification for Fiber-Reinforced Concrete and
D-load culvert, storm drain, and sewer pipe (ASTM Designation
Shotcrete
C 655M).
3. Terminology
2. Referenced Documents
2
3.1 Definitions—For definitions of terms relating to con-
2.1 ASTM Standards:
crete pipe, see Terminology C 822.
A82 Specification for Steel Wire, Plain, for Concrete Re-
inforcement
4. Classification
A 185 Specification for Steel Welded Wire Reinforcement,
4.1 Pipe manufactured in accordance with this specification
Plain, for Concrete
shall be of five classes identified as Class I, Class II, Class III,
A 496 Specification for Steel Wire, Deformed, for Concrete
Class IV, and Class V. The corresponding strength require-
Reinforcement
ments are prescribed in Tables 1-5.
A 497 Specification for Steel Welded Wire Reinforcement,
Deformed, for Concrete
5. Basis of Acceptance
5.1 Unlessotherwisedesignatedbytheowneratthetimeof,
or before placing an order, there are two separate and alterna-
1
This specification is under the jurisdiction of ASTM Committee C13 on
tive bases of acceptance. Independent of the method of
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
acceptance, the pipe shall be designed to meet both the 0.01-in.
Reinforced Sewer and Culvert Pipe.
crack and ultimate strength requirements.
Current edition approved Feb. 1, 2005. Published April 2005. Originally
approved in 1980. Last previous edition approved in 2004 as C 76M–04.
5.1.1 Acceptance on the Basis of Plant Load-Bearing Tests,
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Material Tests, and Inspection of Manufactured Pipe for Visual
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Defects and Imperfections—Acceptability of the pipe in all
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. diameters and classes produced in accordance with 7.1 or 7.2
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
C76M–05
NOTE 1—The total reinforcement area of the inner circular cage and the elliptical cage shall not be less than that specified for the inner cage in Tables
1-5.
NOTE 2—The total reinforcement area of the outer circular cage and the elliptical cage shall not be less than that specified for the outer cage in Tables
...

Questions, Comments and Discussion