ASTM E3223/E3223M-20
(Guide)Standard Guide for Specifying and Testing Field-Constructed Exterior Building Wall System Mockups in New Construction
Standard Guide for Specifying and Testing Field-Constructed Exterior Building Wall System Mockups in New Construction
SIGNIFICANCE AND USE
4.1 This guide is intended to assist the construction team in evaluating the constructability, functionality, sequence of construction, interference, tolerances, component performance, and assembled system performance of the exterior wall systems.
4.2 This guide does not establish specific roles for the parties involved during construction or the contractual obligations of those parties. The role of each party within any specific project should be established and documented before the start of the project.
4.3 This guide is intended for use when specifying construction mockups that are either integrated mockups or off-structure mockups.
4.4 This guide is intended to aid the specifier in the development of a QA mockup program for assessing the performance of exterior walls. It is not intended to provide a comprehensive list of applicable test methods for QA testing available or applicable to a mockup program.
4.5 This guide does not address preconstruction laboratory testing of a wall system.
4.6 This guide is intended to address technical issues with the performance of the wall system and the interconnection of the various components and systems. A mockup may or may not be used as an aesthetic mockup; however, this guide is not intended to address aesthetic issues with the wall system.
4.7 This guide is not intended to provide guidance for construction observation services. However, the mockup may be useful to inform inspectors of the intended construction, sequence, materials, and interface conditions encountered on the project and serve as a standard of quality to which the remainder of construction can be compared.
SCOPE
1.1 This guide provides information to assist in the specification, design, and performance testing of field-constructed exterior wall assemblies (“mockups”) for construction projects. This includes testing procedures appropriate to evaluate the component and assembly performance for water penetration resistance, air leakage resistance, and other test methods that may be applied as part of the quality assurance (QA) program for the installed systems.
1.2 This guide is intended to be applied to exterior wall mockups that include components, systems, and assemblies including, but not limited to, curtain walls, windows, doors, masonry walls, precast concrete, cast-in-place concrete, exterior insulation and finish system (EIFS), roofing interfaces, stucco, wood siding, metal panels, sealants, appurtenances, penetrations, louvers, and combinations thereof. Such mockups are expected to include the intersection between wall systems.
1.3 This guide is not intended to provide a comprehensive list of potential testing that may be applicable to field-constructed mockups. Additional tests may be applicable to mockups for specific projects.
1.4 This guide is not intended to address all possible project delivery methods and as such the requirements listed herein must be evaluated by the specifier for appropriateness with the delivery method.
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical...
General Information
Relations
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E3223/E3223M − 20
Standard Guide for
Specifying and Testing Field-Constructed Exterior Building
1
Wall System Mockups in New Construction
ThisstandardisissuedunderthefixeddesignationE3223/E3223M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
1.1 This guide provides information to assist in the
1.7 This international standard was developed in accor-
specification, design, and performance testing of field-
dance with internationally recognized principles on standard-
constructedexteriorwallassemblies(“mockups”)forconstruc-
ization established in the Decision on Principles for the
tion projects. This includes testing procedures appropriate to
Development of International Standards, Guides and Recom-
evaluate the component and assembly performance for water
mendations issued by the World Trade Organization Technical
penetration resistance, air leakage resistance, and other test
Barriers to Trade (TBT) Committee.
methods that may be applied as part of the quality assurance
(QA) program for the installed systems.
2. Referenced Documents
1.2 This guide is intended to be applied to exterior wall
2
2.1 ASTM Standards:
mockups that include components, systems, and assemblies
C724 Test Method for Acid Resistance of Ceramic Decora-
including, but not limited to, curtain walls, windows, doors,
tions on Architectural-Type Glass
masonry walls, precast concrete, cast-in-place concrete, exte-
C794 TestMethodforAdhesion-in-PeelofElastomericJoint
rior insulation and finish system (EIFS), roofing interfaces,
Sealants
stucco, wood siding, metal panels, sealants, appurtenances,
C1193 Guide for Use of Joint Sealants
penetrations,louvers,andcombinationsthereof.Suchmockups
C1601 Test Method for Field Determination of Water Pen-
are expected to include the intersection between wall systems.
etration of Masonry Wall Surfaces
1.3 This guide is not intended to provide a comprehensive
C1651 Test Method for Measurement of Roll Wave Optical
list of potential testing that may be applicable to field-
Distortion in Heat-Treated Flat Glass
constructed mockups. Additional tests may be applicable to
C1652/C1652M Test Method for Measuring Optical Distor-
mockups for specific projects.
tion in Flat Glass Products Using Digital Photography of
Grids
1.4 This guide is not intended to address all possible project
C1715/C1715M Test Method for Evaluation of Water Leak-
delivery methods and as such the requirements listed herein
age Performance of Masonry Wall Drainage Systems
must be evaluated by the specifier for appropriateness with the
D4541 Test Method for Pull-Off Strength of Coatings Using
delivery method.
Portable Adhesion Testers
1.5 The values stated in either SI units or inch-pound units
D7234 Test Method for Pull-OffAdhesion Strength of Coat-
are to be regarded separately as standard. The values stated in
ings on Concrete Using Portable Pull-Off Adhesion Tes-
each system are not necessarily exact equivalents; therefore, to
ters
ensure conformance with the standard, each system shall be
E283 Test Method for Determining Rate of Air Leakage
used independently of the other, and values from the two
Through Exterior Windows, Skylights, Curtain Walls, and
systems shall not be combined.
Doors Under Specified Pressure Differences Across the
1.6 This standard does not purport to address all of the Specimen
E330 Test Method for Structural Performance of Exterior
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- Windows, Doors, Skylights and CurtainWalls by Uniform
Static Air Pressure Difference
1
This guide is under the jurisdiction of ASTM Committee E06 on Performance
2
of Buildings and is the direct responsibility of Subcommittee E06.55 on Perfor- For referenced ASTM standards, visit the ASTM website, www.astm.org, or
mance of Building Enclosures. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved Nov. 1, 2020. Published December 2020. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/E3223_E3223M-20. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E322
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.