Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) SDR 51 and SDR 64 Sewer Pipe and Fittings

ABSTRACT
This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) SDR 51 and SDR 64 sewer pipe and fittings. In the solvent cement joint, the pipe spigot wedges into the tapered socket and the surfaces fuse together. Joints made with pipe and fittings shall show no signs of leakage when tested. The pipe dimensions, fitting dimensions, pipe flattening, impact resistance, pipe stiffness, joint tightness, and extrusion quality shall be tested to meet the requirements prescribed.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) SDR 51 and SDR 64 sewer pipe and fittings.  
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.  
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Mar-2024
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2658-24 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) SDR 51 and SDR 64 Sewer Pipe and Fittings
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2658-24 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) SDR 51 and SDR 64 Sewer Pipe and Fittings
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2658 − 24
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) SDR 51 and SDR 64
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F2658; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D1600 Terminology for Abbreviated Terms Relating to Plas-
3
tics (Withdrawn 2024)
1.1 This specification covers requirements and test methods
D1784 Classification System and Basis for Specification for
for materials, dimensions, workmanship, flattening resistance,
Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlo-
impact resistance, pipe stiffness, extrusion quality, joining
rinated Poly(Vinyl Chloride) (CPVC) Compounds
systems and a form of marking for type PSM poly(vinyl
D2122 Test Method for Determining Dimensions of Ther-
chloride) (PVC) SDR 51 and SDR 64 sewer pipe and fittings.
moplastic Pipe and Fittings
1.2 Pipe and fittings produced to this specification should be
D2321 Practice for Underground Installation of Thermoplas-
installed in accordance with Practice D2321.
tic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading
1.3 The text of this specification references notes, footnotes,
and appendixes which provide explanatory material. These Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Practice for Determination of the Impact Resistance
notes and footnotes (excluding those in tables and figures) shall
not be considered as requirements of the specification. of Thermoplastic Pipe and Fittings by Means of a Tup
(Falling Weight)
1.4 The values stated in inch-pound units are to be regarded
D2564 Specification for Solvent Cements for Poly(Vinyl
as standard. The values given in parentheses are mathematical
Chloride) (PVC) Plastic Piping Systems
conversions to SI units that are provided for information only
D2749 Symbols for Dimensions of Plastic Pipe Fittings
and are not considered standard.
D2855 Practice for the Two-Step (Primer and Solvent Ce-
1.5 The following precautionary caveat pertains only to the
ment) Method of Joining Poly (Vinyl Chloride) (PVC) or
test methods portion, Section 8, of this specification. This
Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and
standard does not purport to address all of the safety concerns,
Piping Components with Tapered Sockets
if any, associated with its use. It is the responsibility of the user
D3034 Specification for Type PSM Poly(Vinyl Chloride)
of this standard to establish appropriate safety, health, and
(PVC) Sewer Pipe and Fittings
environmental practices and determine the applicability of
F412 Terminology Relating to Plastic Piping Systems
regulatory limitations prior to use.
2.2 Federal Standard:
1.6 This international standard was developed in accor-
4
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the 2.3 Military Standard:
4
Development of International Standards, Guides and Recom-
MIL-STD-129 Marking for Shipment and Storage
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
3. Terminology
3.1 Definitions—Definitions are in accordance with Termi-
2. Referenced Documents
nology F412, and abbreviations are in accordance with Termi-
2
2.1 ASTM Standards:
nology D1600, unless otherwise specified. The abbreviation of
D618 Practice for Conditioning Plastics for Testing
poly(vinyl chloride) plastics is PVC.
3.1.1 The term PSM is not an abbreviation but rather an
arbitrary designation for a product having certain dimensions.
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved April 1, 2024. Published May 2024. Previous edition
approved in 2019 as F2658 – 07(2019). DOI: 10.1520/F2658-24.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or The last approved version of this historical standard is referenced on
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM www.astm.org.
4
Standardsvolume information, refer to the standard’s Document Summary page on Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
the ASTM website. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2658 − 07 (Reapproved 2019) F2658 − 24
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) SDR 51 and SDR 64
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F2658; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact
resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) SDR
51 and SDR 64 sewer pipe and fittings.
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and
footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification. This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory
limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
3
D1600 Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)
D1784 Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Feb. 1, 2019April 1, 2024. Published March 2019May 2024. Previous edition approved in 20132019 as F2658 – 07(2013). DOI:
10.1520/F2658-07R19.07(2019). DOI: 10.1520/F2658-24.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standardsvolume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2658 − 24
D2444 Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2749 Symbols for Dimensions of Plastic Pipe Fittings
D2855 Practice for the Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated
Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets
D3034 Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
2.2 Federal Standard:
4
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2.3 Military Standard:
4
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Definitions—Definitions are in accordance with Terminology F412, and abbreviations are in accordance with Terminology
D1600, unless otherwis
...

Questions, Comments and Discussion