Standard Practice for Determining Application Rate of Bituminous Distributors

SCOPE
1.1 This practice covers the determination of transverse and longitudinal application rate of asphalt distributors in gallons per square yard (or litres per square metre).
1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
1.3 The values given in inch-pound units are to be regarded as the standard. The SI values given in parentheses are for information purposes only.

General Information

Status
Historical
Publication Date
09-Jun-1999
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2995-99 - Standard Practice for Determining Application Rate of Bituminous Distributors
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 2995 – 99
Standard Practice for
Estimating Application Rate of Bituminous Distributors
This standard is issued under the fixed designation D 2995; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 4. Apparatus
1.1 This practice covers the determination of transverse and 4.1 Test Methods A and B:
longitudinal application rate of asphalt distributors in gallons 4.1.1 Balance, sensitive to 0.1 g.
per square yard (or litres per square metre). 4.1.2 Weighing Box or Balance Shield, to protect balance
1.2 This standard does not purport to address all of the from wind when the balance is in use at the project site (see
safety concerns, if any, associated with its use. It is the Fig. 1).
responsibility of the user of this standard to establish appro- 4.1.3 Balance Table and Work Table, for weighing.
priate safety and health practices and determine the applica- 4.2 Test Method B:
bility of regulatory limitations prior to use. 4.2.1 Elliptical Containers, measuring approximately 3.5 in.
1.3 The values given in inch-pound units are to be regarded (88.9 mm) along the short axis and 9 in. (228.6 mm) along the
as the standard. The SI values given in parentheses are for long axis of the ellipse and 8 in. (203.2 mm) in height, capable
information purposes only. of an internal volume of approximately 1 gal.
4.2.2 Rubber Bands, capable of a snug fit when stretched
2. Summary of Practice
around the elliptical containers.
2.1 Test Method A:
4.2.3 Stopwatch, capable of recording to the nearest 0.1 s.
2.1.1 Preweighed calibration pads are placed on the surface
5. Materials
of the roadway in front of the distributor to be calibrated. The
asphalt distributor to be calibrated is driven over the calibration 5.1 Test Method A:
2 2
pads while spraying asphalt. The calibration pads are removed 5.1.1 Geotextile Pads, weighing a minimum of 8 oz/yd
from the roadway and reweighed. The weight of asphalt and measuring 12 in. (304.8 mm) by 12 in. (304.8 mm).
applied to the pads is determined by subtraction and the rate of 5.1.2 Aluminized Duct Tape, measuring 2 in. (50.8 mm)
application is calculated. wide and 6 in. (152.4 mm) long.
2.2 Test Method B: 5.1.3 Butcher Paper #50, measuring 30 in. (762 mm) by
2.2.1 Containers are placed under each nozzle of a bitumi- 950 ft, for temporary protection of geotextile pads during
nous distributor and bituminous material is sprayed into the calibration.
containers for a known period of time. The volume of 5.2 Test Method B:
bituminous material sprayed after this period is calculated. The 5.2.1 Plastic Bags, capable of fitting inside the elliptical
transverse uniformity of bituminous material sprayed on the cans but of sufficiently larger dimension to allow folding over
pavement is obtained from this calculation and the distribution the edge of the elliptical containers once placed inside.
of bituminous material applied longitudinally on the pavement
6. Procedure (Transverse Application Rate)
is calculated as a function of the distributor velocity.
6.1 Test Method A:
3. Significance and Use
6.1.1 Select enough of the geotextile fabric pads so that
3.1 The amount of bituminous material applied to a pave- when placed end to end on the roadway a continuous strip is
ment surface using a bituminous distributor can be estimated created across the width of the roadway to be sprayed with
using the described procedure. asphalt.
1 2
This practice is under the jurisdiction of ASTM Committee D-4 on Road and Non-woven, needle punched, heat fused on one side geotextiles by Phillips
Paving Materials and is the direct responsibility of Subcommittee D04.24 on Fibers, Monsanto, and Amoco have been found to be suitable materials for this
Bituminous Surface Treatments. purpose.
Current edition approved June 10, 1999. Published July 1999. Originally Butcher paper from Baumann Paper Co., Baumann Rd., Lexington, KY has
published as D 2995 – 71. Last previous edition D 2995 – 93 (1998). been found to be suitable for this purpose.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
D2995–99
6.1.7 Weigh each pad to the nearest 0.1 g. Record the weight
of each pad and the pad position on the roadway on the report
form.
6.2 Test Method B:
6.2.1 Insert one plastic bag into each elliptical can. Wrap the
excess plastic over the top of the can and secure with a rubber
band.
6.2.2 Record the weight of the elliptical can, plastic and
rubber band assembly to the nearest 0.1 g.
6.2.3 Place one can assembly under each nozzle to be
calibrated in the spraybar of the asphalt distributor. Ensure that
the top of the can assembly is equal to or above the bottom of
each nozzle.
6.2.4 Activate the spraybar so that when the asphalt is
sprayed from each nozzle it is completely collected in each
preweighed can assembly. Start the stopwatch the instant the
asphalt begins to fill the can assembly.
6.2.5 Stop the flow of asphalt to the spraybar when the can
assembly is approximately ⁄4 full. Stop the stopwatch the
FIG. 1 Weighing Box and Balance
instant the asphalt stops flowing into the can assembly.
6.2.6 Record the weight of each can assembly in the proper
6.1.2 Create a loop with the duct tape with the adhesive side
space on the report form.
facing out. Place two loops of duct
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.